How do you charge an R134a refrigerator with a cap tube system? - Answer-Weigh in the charge per the nameplate. What is the best thing to do before evacuating a refrigeration system? - Answer-Evacuate the gauge and pump connections to ensure all connections are tight. If a micron gauge is not working properly, what is the first thing to do to correct it? - Answer-Pour alcohol into the inlet port to clean oil out of it. In the "real world" how often is it practical to replace the oil in a vacuum pump? - Answer-Vacuum pumps must always have their oil changed after each use. What precautions should be taken when charging liquid through the suction service valve? - Answer-Restrict the flow of liquid if the amperage is above 10% of RLA or the valve frosts What are some of the considerations when charging refrigerant into the system high side? - Answer-The unit capacity is over 5 pounds, in a vacuum, and the compressor is off. Why is the compressor started in the 2nd part of a triple evacuation? - Answer-To release moisture that may be trapped in the oil. Which of the following will damage a 3Ø motor? - Answer-Loss of phase or a voltage imbalance over 2%. If you need a 30 amp compressor contactor, which of the following is the best choice - Answer-30 amp inductive - 20 amp resistive The incoming voltage to a contactor is 240 and the voltage leaving is 235. What is the proper corrective action necessary? - Answer-Replace the contacts or the contactor. Why are starting components needed on a 1Ø compressor motor? - Answer-Single phase motors need a phase shift in order to start the rotor turning. The proper wiring sequence for a potential relay is: - Answer-5 (common), 2 (start), 1 (run) When troubleshooting a potential relay, the terminals 5, 2, and 1 refer to: - Answer-.5 and 2 are the coil, 1 and 2 are the relay contacts.

Content preview

Commercial Refrigeration Test Chapter
8, 9 Exam Questions and Answers
How do you charge an R134a refrigerator with a cap tube system? - Answer-Weigh in
the charge per the nameplate.

What is the best thing to do before evacuating a refrigeration system? - Answer-
Evacuate the gauge and pump connections to ensure all connections are tight.

If a micron gauge is not working properly, what is the first thing to do to correct it? -
Answer-Pour alcohol into the inlet port to clean oil out of it.

In the "real world" how often is it practical to replace the oil in a vacuum pump? -
Answer-Vacuum pumps must always have their oil changed after each use.

What precautions should be taken when charging liquid through the suction service
valve? - Answer-Restrict the flow of liquid if the amperage is above 10% of RLA or the
valve frosts

What are some of the considerations when charging refrigerant into the system high
side? - Answer-The unit capacity is over 5 pounds, in a vacuum, and the compressor is
off.

Why is the compressor started in the 2nd part of a triple evacuation? - Answer-To
release moisture that may be trapped in the oil.

Which of the following will damage a 3Ø motor? - Answer-Loss of phase or a voltage
imbalance over 2%.

If you need a 30 amp compressor contactor, which of the following is the best choice -
Answer-30 amp inductive - 20 amp resistive

The incoming voltage to a contactor is 240 and the voltage leaving is 235. What is the
proper corrective action necessary? - Answer-Replace the contacts or the contactor.

Why are starting components needed on a 1Ø compressor motor? - Answer-Single
phase motors need a phase shift in order to start the rotor turning.

The proper wiring sequence for a potential relay is: - Answer-5 (common), 2 (start), 1
(run)

When troubleshooting a potential relay, the terminals 5, 2, and 1 refer to: - Answer-.5
and 2 are the coil, 1 and 2 are the relay contacts.

Document information

Uploaded on
September 10, 2024
Number of pages
2
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
lectknancy
3.8
(80)
Sold
328
Followers
27
Items
26139
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions