100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

ACI Test All Answers Correct

Rating
-
Sold
-
Pages
9
Grade
A+
Uploaded on
06-08-2024
Written in
2024/2025

ACI Test All Answers Correct - What is the maximum duration allowed between the first and final portions of a composite sample collection? The maximum allowable time between obtaining the first and last portions of a composite sample is 15 minutes. - Should wet sieving of a concrete sample occur after the individual samples are mixed into a composite? False. Wet sieving should not be conducted after the samples are combined; it has distinct timing requirements. - After obtaining a composite sample, within how many minutes must tests for slump, temperature, and air content commence? These tests are required to start within 5 minutes of acquiring the composite sample. - When must test specimens be molded after the composite sample collection? The molding of test specimens should occur within 15 minutes after the collection of the composite sample. - What precautions should be taken with concrete samples to prevent negative effects? Concrete samples should be safeguarded from sunlight, wind, rapid evaporation, and contamination. - What is the minimum volume of concrete sample needed for molding strength test specimens? A minimum concrete sample size of 28 liters (1 cubic foot) is required for this purpose. - Is obtaining a representative sample the main goal of the sampling process? True. Ensuring that the sample is representative is the key objective of the sampling procedure. - How many portions should be collected from a revolving drum truck mixer during sampling? Concrete should be taken from 2 or more sections of the batch when sampling from a revolving drum truck mixer. - What circumstances call for wet sieving of concrete? Wet sieving is necessary if the concrete includes aggregates larger than what is acceptable for testing. - Is it permissible to use three small containers on the subgrade when sampling from a paving mixer? False. This method is not acceptable for obtaining the required concrete samples. --- TEMPERATURE MEASUREMENTS - How long may it take for temperature stabilization when the nominal maximum size (NMS) of coarse aggregate exceeds a certain dimension? It may take up to 20 minutes for the temperature to stabilize when the NMS of coarse aggregate is greater than 3 inches. - What size container is necessary to ensure proper temperature measurement in concrete? The container must be large enough to allow for at least 3 inches (or 3 times the NMS) of concrete to surround the temperature measuring device on all sides. - What accuracy should the temperature measuring device have, and what range must it encompass? The device should accurately measure temperature within ±1°F and cover a temperature range from 30°F to 120°F. - Is a composite sample required if the only intention is to measure temperature? True. A composite sample is not necessary for determining temperature alone. - How frequently should the temperature measuring device be calibrated? The calibration must be performed annually or whenever there is doubt regarding its accuracy.

Show more Read less
Institution
Course









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Study
Course

Document information

Uploaded on
August 6, 2024
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ACI Test All Answers Correct
- What is the maximum duration allowed between the first and final portions of a composite sample
collection?

The maximum allowable time between obtaining the first and last portions of a composite sample is 15
minutes.



- Should wet sieving of a concrete sample occur after the individual samples are mixed into a
composite?

False. Wet sieving should not be conducted after the samples are combined; it has distinct timing
requirements.



- After obtaining a composite sample, within how many minutes must tests for slump, temperature, and
air content commence?

These tests are required to start within 5 minutes of acquiring the composite sample.



- When must test specimens be molded after the composite sample collection?

The molding of test specimens should occur within 15 minutes after the collection of the composite
sample.



- What precautions should be taken with concrete samples to prevent negative effects?

Concrete samples should be safeguarded from sunlight, wind, rapid evaporation, and contamination.



- What is the minimum volume of concrete sample needed for molding strength test specimens?

A minimum concrete sample size of 28 liters (1 cubic foot) is required for this purpose.



- Is obtaining a representative sample the main goal of the sampling process?

True. Ensuring that the sample is representative is the key objective of the sampling procedure.



- How many portions should be collected from a revolving drum truck mixer during sampling?

Concrete should be taken from 2 or more sections of the batch when sampling from a revolving drum
truck mixer.

, - What circumstances call for wet sieving of concrete?

Wet sieving is necessary if the concrete includes aggregates larger than what is acceptable for testing.



- Is it permissible to use three small containers on the subgrade when sampling from a paving mixer?

False. This method is not acceptable for obtaining the required concrete samples.



---



TEMPERATURE MEASUREMENTS



- How long may it take for temperature stabilization when the nominal maximum size (NMS) of coarse
aggregate exceeds a certain dimension?

It may take up to 20 minutes for the temperature to stabilize when the NMS of coarse aggregate is
greater than 3 inches.



- What size container is necessary to ensure proper temperature measurement in concrete?

The container must be large enough to allow for at least 3 inches (or 3 times the NMS) of concrete to
surround the temperature measuring device on all sides.



- What accuracy should the temperature measuring device have, and what range must it encompass?

The device should accurately measure temperature within ±1°F and cover a temperature range from
30°F to 120°F.



- Is a composite sample required if the only intention is to measure temperature?

True. A composite sample is not necessary for determining temperature alone.



- How frequently should the temperature measuring device be calibrated?

The calibration must be performed annually or whenever there is doubt regarding its accuracy.
$12.35
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
bestscores1 Kent State University
Follow You need to be logged in order to follow users or courses
Sold
12
Member since
1 year
Number of followers
0
Documents
1369
Last sold
1 month ago
ReadEase

Welcome to ReadEase, your ultimate resource for exam preparation. At ReadEase, we specialize in providing comprehensive study materials and resources to help you excel in your exams. Whether you're preparing for standardized tests, professional certifications, or academic assessments, our finely curated collection covers a wide range of subjects and levels. From practice tests and study guides to expert tips and strategies, we're here to support your journey to success. ReadEase is committed to availing high-quality educational content, helping you thrive and achieve your academic and professional goals. Have any questions? We're just a message away.

Read more Read less
4.3

4 reviews

5
2
4
1
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions