Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 13 pages
Exam (elaborations)

ACI Concrete Field Testing Technician- Grade I

Document preview thumbnail
Preview 2 out of 13 pages

ACI Concrete Field Testing Technician- Grade I 1. The sensor of the temperature measuring device shall be submerged a minimum of: ️ 3 in. [75 mm] into the freshly mixed concrete. 2. The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to ±: ️ 1 degree F [0.5 C], throughout a range of: ️ 30 degrees F to 120 F [0 C to 50 C]. 3. The temperature measuring device shall be calibrated: ️ Annually, or whenever there is a question of: ️ accuracy. 4. The temperature of concrete may be measured in a wheelbarrow. ️ True 5. The temperature of concrete may be measured in a wall form. ️ True 6. A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temperature. ️ False 7. What must be done to the sample container prior to sampling the concrete? ️ Dampen (with water) 8. What must be done to the concrete surrounding the temperature measuring device after the device is submerged in the fresh concrete? ️ Gently press the concrete around the temperature measuring device at the surface of the concrete. 9. How long must the temperature measuring device remain in the freshly mixed concrete? ️ At least 2 minutes but not more than 5 minutes. 10. After the temperature of the concrete is read, what is required? ️ Reporting of temperature. 11. The temperature of concrete is reported to the nearest: ️ 1 degree F [0.5 C]. 12. According to ASTM C1064, what is one reason to take the temperature of concrete? ️ Verify conformance to a specified requirement for temperature of concrete. 13. A maximum temperature of freshly mixed concrete is specified in ASTM C1064. ️ False 14. The sample of concrete used for temperature determination must be rodded 25 times. ️ False 15. Sampling by this method is required when tests are to be made to determine: ️ Compliance with specification requirements. 16. This method covers sampling from four types of mixers which are: ️ Stationary mixers, paving mixers, revolving drum mixers, and open top mixers. 17. The maximum allowable time between obtaining the first and final portions of a composite sample is: ️ 15 minutes. 18. Portions of a composite sample shall be thoroughly remixed before beginning tests on the sample. ️ True 19. The maximum elapsed time allowed between obtaining the final portion of the composite sample and beginning the tests for slump, temperature, and air content is: ️ 5 minutes

Content preview

ACI Concrete Field Testing Technician- Grade I
1. The sensor of the temperature measuring device shall be submerged a minimum of: ✔️ 3 in. [75
mm] into the freshly mixed concrete.



2. The temperature measuring device shall have a capacity of measuring temperature of freshly mixed
concrete to ±: ✔️ 1 degree F [0.5 C], throughout a range of: ✔️ 30 degrees F to 120 F [0 C to 50 C].



3. The temperature measuring device shall be calibrated: ✔️ Annually, or whenever there is a question
of: ✔️ accuracy.



4. The temperature of concrete may be measured in a wheelbarrow. ✔️ True



5. The temperature of concrete may be measured in a wall form. ✔️ True



6. A composite sample of concrete is required even if the only purpose for obtaining the sample is to
determine temperature. ✔️ False



7. What must be done to the sample container prior to sampling the concrete? ✔️ Dampen (with
water)



8. What must be done to the concrete surrounding the temperature measuring device after the device is
submerged in the fresh concrete? ✔️ Gently press the concrete around the temperature measuring
device at the surface of the concrete.



9. How long must the temperature measuring device remain in the freshly mixed concrete? ✔️ At least
2 minutes but not more than 5 minutes.



10. After the temperature of the concrete is read, what is required? ✔️ Reporting of temperature.



11. The temperature of concrete is reported to the nearest: ✔️ 1 degree F [0.5 C].

, 12. According to ASTM C1064, what is one reason to take the temperature of concrete? ✔️ Verify
conformance to a specified requirement for temperature of concrete.



13. A maximum temperature of freshly mixed concrete is specified in ASTM C1064. ✔️ False



14. The sample of concrete used for temperature determination must be rodded 25 times. ✔️ False



15. Sampling by this method is required when tests are to be made to determine: ✔️ Compliance with
specification requirements.



16. This method covers sampling from four types of mixers which are: ✔️ Stationary mixers, paving
mixers, revolving drum mixers, and open top mixers.



17. The maximum allowable time between obtaining the first and final portions of a composite sample
is: ✔️ 15 minutes.



18. Portions of a composite sample shall be thoroughly remixed before beginning tests on the sample.
✔️ True



19. The maximum elapsed time allowed between obtaining the final portion of the composite sample
and beginning the tests for slump, temperature, and air content is: ✔️ 5 minutes.



20. The molding of strength test specimens shall begin within: ✔️ 15 minutes after fabricating the
composite sample.



21. The concrete sample must be protected from contamination and: ✔️ Rapid evaporation.



22. The minimum size sample for making strength test specimens is: ✔️ 28 L (1 ft³).

Document information

Study
Uploaded on
August 6, 2024
Number of pages
13
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.02

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
bestscores1
4.4
(5)
Sold
18
Followers
0
Items
1369
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions