100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

EPA 608 Type 3 exam with 100% Complete Solutions Lates (Graded A+)

Rating
-
Sold
-
Pages
16
Grade
A+
Uploaded on
11-06-2024
Written in
2023/2024

EPA 608 Type 3 exam with 100% Complete Solutions Lates (Graded A+) On low pressure chillers, moisture typically enters the refrigerant system through air leaks from areas with gaskets or fittings The maximum test pressure for leak testing a low pressure centrifugal is: 10 psig Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller ... A hydrostatic tube test kit is used to: determine if a tube leaks Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds ____ of the charge per year. 35% Refrigerant recovery typically start with liquid recovery it is faster. ... A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: 15 psig According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above ____ during a standing vacuum test, the system should be checked for leaks. 2.5 mm Hg The primary water source for a recovery unit condensing coil is _____. local municipal water supply When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells before changing with liquid? 16.9" Hg vacuum After recovering the liquid refrigerant you must: recover the vapor refrigerant According to the EPA there is approximately _____ refrigerant vapor left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed. 100 pounds Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can cause the: system water to freeze A system does not have to be evacuated all the way to the required level when: leaks in the appliance make evacuation to the prescribed level unattainable Which of the following repairs would ALWAYS be considered "major" under EPA's replacement of evaporator coil Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the purpose of opening the system for a non-major repair? warming the refrigerant If you are using a recovery machine manufactured AFTER 11-15-93 you must evacuate an low pressure appliance to _______ before making a major repair. 25 mm of Hg absolute After reaching the required recovery vacuum on a chiller, you should Wait for at least a few minutes to see if the system pressure rises, indicating that there is till refrigerant in a liquid form or in the oil The pressure corresponding to 32 F for R-123 20 inches of HG vacuum When evacuating a system, the use of too large a vacuum pump can cause? trapped water to freeze Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: 35F During the evacuation of a system containing large amounts of moisture you can prevent freezing of this moisture by increasing the pressure with______gas nitrogen ASHRAE standard 15-1994 requires that each machinery room must activate an alarm and mechanical ventilation beofre refrigerant concentrations exceed: the threshold limit valve and time weighted average The typical design burst pressure for a rupture disk on a low pressure centrifugal air-conditioning system is set at_______ 15 psi Heat pumps that have been retrofitted from R22 to R407C should be leak checked with: pressurized nitrogen When a new system has been assembled, the first thing to do is: pressurize the system with inert gas and leak check EPA regulations require that leaking commercial or industrial process refrigeration equipment must be repaired when the leak rate exceeds______ of the charge per year. 35% Prior to replacing the condenser coil in a high pressure system, the refrigerant was recovered and stored in a refillable container. The refrigerant: can probably be charged back into the system R-410A requires recovery tanks rated for at least: 400 psig to recover liquid refrigerant you must connect one hose to the liquid line The primary water source for cooling the condenser of a water-cooled recovery unit is: local municipal water supply

Show more Read less
Institution
EPA 608 Type 3
Course
EPA 608 Type 3










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA 608 Type 3
Course
EPA 608 Type 3

Document information

Uploaded on
June 11, 2024
Number of pages
16
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUDYLAB2023 Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
776
Member since
3 year
Number of followers
624
Documents
5428
Last sold
1 week ago
STUDYLAB 2022/2023

Here you will find reliable study resources that will help you prepare, revise and pass your examinations for all majors and modules. For assistance with online tutoring and Help with Class assignments, thesis, dissertations and essay writing with a guaranteed PASS & QUALITY reach out: . Good Luck.

3.8

149 reviews

5
71
4
23
3
27
2
7
1
21

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions