100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

API 653 Recertification Quiz with 100% Correct

Rating
-
Sold
-
Pages
5
Grade
A+
Uploaded on
31-05-2024
Written in
2023/2024

API 653 Recertification Quiz with 100% Correct Per API 653 , with of the following is required when converting an existing tank to operation at elevated temperatures when it was not originally designed and constructed to API 650, Appendix M? - Correct Answer ️️ -The Shell to bottom joint shall be evaluated for fatigue When removing an existing tank bottom, all arc-gouged areas of the tank shell-to- bottom shall be: - Correct Answer ️️ -examined using magnetic particle inspection, and defective areas repaired and re-examined. If RBI assessment has been conducted and the tank has cathodic protection plus a thin- film lining, the maximum inspection interval is: - Correct Answer ️️ -14 years When installing a new nozzle in a tank of unknow material, what stress value should be used to calculate the required shell thickness and reinforcement? - Correct Answer ️️ - 20,000 lbf/in2 In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a wet environment. - Correct Answer ️️ -may double with every 18 °F increase in temperature above 77 °F. Grade 350W/50W is acceptable for tank plate to a maximum thickness of: - Correct Answer ️️ -45mm (1.75in) if fully killed and made to a fine grain practice. If an RBI assessment has been conducted and the tank has a release prevention barrier, the maximum initial inspection interval is: - Correct Answer ️️ -25 years As an alternative to the procedures in API 653 for the evaluation of any thinning of the tank shell below minimum required wall thickness may be evaluated for continued service using which code? - Correct Answer ️️ -API RP 579, section 4, 5 or 6. When welding on a tank shell constructed of Group I steel that is greater than 1.5 inches thick below what minimum metal temperature ?preheat? - Correct Answer ️️ - 200°F When evaluated an existing temperature services tank, which has a successful service history of operation but was not originally designed and constructed to the requi

Show more Read less
Institution
Api 653
Course
Api 653









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Api 653
Course
Api 653

Document information

Uploaded on
May 31, 2024
Number of pages
5
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

API 653 Recertification Quiz with 100% Correct Per API 653 , with of the following is required when converting an existing tank to operation at elevated temperatures when it was not originally designed and constructed to API 650, Appendix M? - Correct Answer ✔️✔️-The Shell to bottom joint shall be evaluated for fatigue When removing an existing tank bottom, all arc -gouged areas of the tank shell -to-
bottom shall be: - Correct Answer ✔️✔️-examined using magnetic particle inspection, and defective areas repaired and re -examined. If RBI assessment has been conducted and the tank has cathodic protection plus a thin -
film lining, the maximum inspection interval is: - Correct Answer ✔️✔️-14 years When installing a new nozzle in a tank of unknow material, what stress value should be used to calculate the required shell thickness and reinforcement? - Correct Answer ✔️✔️-
20,000 lbf/in2 In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a wet environment. - Correct Answer ✔️✔️-may double with every 18 °F increase in temperature above 77 °F. Grade 350W/50W is acceptable for tank plate to a maximum thickness of: - Correct Answer ✔️✔️-45mm ( 1.75in) if fully killed and made to a fine grain practice. If an RBI assessment has been conducted and the tank has a release prevention barrier, the ma ximum initial inspection interval is: - Correct Answer ✔️✔️-25 years As an alternative to the procedures in API 653 for the evaluation of any thinning of the tank shell below minimum required wall thickness may be evaluated for continued service using whic h code? - Correct Answer ✔️✔️-API RP 579, section 4, 5 or 6. When welding on a tank shell constructed of Group I steel that is greater than 1.5 inches thick below what minimum metal temperature ?preheat? - Correct Answer ✔️✔️-
200°F When evaluated an existi ng temperature services tank, which has a successful service history of operation but was not originally designed and constructed to the requirement of API 650, appendix M, which condition temperature has to be used? - Correct Answer ✔️✔️-The max Operating Temperature shall not exceed the temperature at which the tank has successfully operated in the pass. Flange material used for tank repair and alteration shall meet the minimum requirements for the material specifications according to: - Correct Answer ✔️✔️-The as built standard which is an advantage of thick film UN -REINFORCED linings ? - Correct Answer ✔️✔️-
Fast curing and can be put back in service after 24 hours at normal ambient temperature. The perimeter welds on a welded -on patch plate in the critic al zone should be ? - Correct Answer ✔️✔️-Two-pass and examined visually and by either MP or PT. Existent welds on a tank shell are found to e closer than allowed by API 650 (7th Edition). Under what conditions can these welds be considered to be acceptabl e for

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BrittieDonald Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
399
Member since
2 year
Number of followers
162
Documents
20443
Last sold
9 hours ago
BrittieDonald Study Solutions.

Get Help in Your Due Online and Actual Exams, Assignments with Well Researched and Up-to date Study Materials for Guaranteed Success

3.5

89 reviews

5
41
4
13
3
7
2
5
1
23

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions