Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Boiler Operator & Stationary Steam Engineer Exam Questions With Complete Solutions Latest Update 2026/2027 (GRADED A+)

Rating
-
Sold
-
Pages
6
Grade
A+
Uploaded on
28-05-2024
Written in
2023/2024

Boiler Operator/ Stationary Steam Engineer Exam Questions With Complete Solutions Latest Update 2024/2025 (GRADED) Materials of construction of a flue gas scrubber system must be selected to resist what hostile conditions? - Answer low pH conditions and abrasion the efficiency of a spray pond or cooling tower is based on? - Answer wet bulb temperature or relative humidity of the ambient air when placing an induced draft cooling tower into service, which is the last step performed? - Answer start the i.d. fans when operating an induced draft cooling tower, which of the following statements is FALSE - Answer it is more economical to operate one fan at high speed than two fans at low speed what condition could be prevented by keeping the pH of water greater than 7? - Answer corrosion which chemical is often used to control algae accumulation in cooling towers? - Answer copper sulfate (LP) what is the minimum percentage of oxygen that must be present in a confined space before entering? - Answer 19.5% (LP) which of the following should you not tag and lock out when a boiler is shut down for inspection? - Answer top tri cock or boiler vent what is the first thing that must be done when starting up a brand new boiler? - Answer boil the boiler out which of the following is not done during a boiler start up? - Answer fill the boiler to the NOWL

Show more Read less
Institution
Boiler Operator/ Stationary Steam Engineer
Course
Boiler Operator/ Stationary Steam Engineer

Content preview

Boiler Operator/ Stationary Steam Engineer Exam
Questions With Complete Solutions Latest Update
2024/2025 (GRADED)

what is used to keep SO2 down? - Answer wet and dry scrubbers

a wet scrubber that has been maintained properly has the capability of absorbing
______% of the SO2 in the flue gas - Answer 90%

Materials of construction of a flue gas scrubber system must be selected to resist what
hostile conditions? - Answer low pH conditions and abrasion

the efficiency of a spray pond or cooling tower is based on? - Answer wet bulb
temperature or relative humidity of the ambient air

when placing an induced draft cooling tower into service, which is the last step
performed? - Answer start the i.d. fans

when operating an induced draft cooling tower, which of the following statements is
FALSE - Answer it is more economical to operate one fan at high speed than two fans
at low speed

what condition could be prevented by keeping the pH of water greater than 7? - Answer
corrosion

which chemical is often used to control algae accumulation in cooling towers? - Answer
copper sulfate

(LP) what is the minimum percentage of oxygen that must be present in a confined
space before entering? - Answer 19.5%

(LP) which of the following should you not tag and lock out when a boiler is shut down
for inspection? - Answer top tri cock or boiler vent

what is the first thing that must be done when starting up a brand new boiler? - Answer
boil the boiler out

which of the following is not done during a boiler start up? - Answer fill the boiler to the
NOWL

when starting a fire in a coal_fired boiler with chain grates or traveling grates, how much
coal should be on the grates? - Answer 3-4 inches

, when should a non-return valve be opened when putting a boiler on line? - Answer
when the boiler pressure builds to 10 to 25 pose below the header pressure

if a steam oiler is being taken out of service, what step should be taken first? - Answer
operate the sootblowers

(LP) when taking a boiler off-line what is the first step? - Answer secure the fire

what is the last step to be performed when shutting down a boiler? - Answer close the
feedwater supply valve

when taking a boiler out of service, what is one thing you do not do? - Answer close the
vent

how long may the operator be away from the boiler - Answer the time it takes to go from
1/2 sight glass of water to no water showing

how long does it usually take for the boiler water level to go from half a glass to no
water showing? - Answer 2-8 min

how often should the flame scanner be tested? - Answer weekly

(LP) when testing a safety valve manually on a low-pressure boiler, how long do you
hold it open? - Answer 5-10 seconds

with a tubular gauge glass, how do you warm up the glass - Answer open the drain
valve and crack open the steam valve

bad washers in a low pressure boiler's gauge glass - Answer can cause a false water
level reading in the gauge glass

what can you do to find the water level if the gauge glass is broken - Answer open the tri
cocks individually

if a priming situation occurs, what should you do? - Answer reduce the firing rate and
blow the boiler down to gain control of the water level

if the boiler is priming so badly that you cannot see the water level, what action should
be taken? - Answer close the main steam stop valve long enough to determine the
water level

the water level in a steam boiler has been proven to be low. what step should be taken
first? - Answer stop the fuel and air suppies

Written for

Institution
Boiler Operator/ Stationary Steam Engineer
Course
Boiler Operator/ Stationary Steam Engineer

Document information

Uploaded on
May 28, 2024
Number of pages
6
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ExcelAcademia2026 Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
2273
Member since
4 year
Number of followers
1650
Documents
9069
Last sold
2 days ago
EXCEL ACADEMIA TUTORS

At Excel Academia Tutoring, You will get solutions to all subjects in both assignments and major exams. Contact me for assistance. Good luck! Well-researched education materials for you. Expert in Nursing, Mathematics, Psychology, Biology etc. My Work has the Latest & Updated Exam Solutions, Study Guides and Notes (100% Verified Solutions that Guarantee Success)

3.7

380 reviews

5
157
4
80
3
72
2
23
1
48

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions