Residential Electrician Exam #1Complete Questions With 100% Correct Answers. Graded A+ Ferrous metal enclosures for grounding electrode conductors shall be _____. a) electrically continuous b) electrically isolated c) not permitted d) rigid metal conduit (RMC) only A: electrically continuous Ref: 250.64(E) Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. a) switched receptacles for cord-connected incandescent luminaires b) permanently installed incandescent luminaires c) ceiling fans with luminaires d) holiday decorative lighting B: permanently installed incandescent luminaires Ref: 404.14(E) All 125-volt, single-phase, 15- and 20-ampere receptacles installed in residential garages shall be _____. I) protected by a listed arc-fault interrupter II) provided with ground-fault circuit-interrupter protection a) I only b) II only c) both I and II d) neither I nor II B: II only Ref: 210.8(A)(2); 210.12(B) The MAXIMUM allowable ampacity of size 18 AWG fixture wire is _____ amperes. a) 12 b) 10 c) 8 d) 6 D: 6 Ref: Tbl. 402.5 A receptacle outlet installed for a gas or electric clothes dryer in the laundry room of a dwelling unit must be installed within at LEAST _____ feet of the intended location of the dryer. a) 6 b) 4 c) 10

Content preview

Residential Electrician Exam #1Complete Questions With
100% Correct Answers. Graded A+
Ferrous metal enclosures for grounding electrode conductors shall be _____.
a) electrically continuous
b) electrically isolated
c) not permitted
d) rigid metal conduit (RMC) only
A: electrically continuous
Ref: 250.64(E)
Unless listed for the control of other loads, general use dimmer switches shall
only be used to control _____.
a) switched receptacles for cord-connected incandescent luminaires
b) permanently installed incandescent luminaires
c) ceiling fans with luminaires
d) holiday decorative lighting
B: permanently installed incandescent luminaires
Ref: 404.14(E)
All 125-volt, single-phase, 15- and 20-ampere receptacles installed in residential
garages shall be _____.
I) protected by a listed arc-fault interrupter
II) provided with ground-fault circuit-interrupter protection
a) I only
b) II only
c) both I and II
d) neither I nor II
B: II only
Ref: 210.8(A)(2); 210.12(B)
The MAXIMUM allowable ampacity of size 18 AWG fixture wire is _____ amperes.
a) 12
b) 10
c) 8
d) 6
D: 6
Ref: Tbl. 402.5
A receptacle outlet installed for a gas or electric clothes dryer in the laundry room
of a dwelling unit must be installed within at LEAST _____ feet of the intended
location of the dryer.
a) 6
b) 4
c) 10
d) 3
A: 6
Ref: 210.50(C)

, Which of the following listed conductors are required to have overcurrent
protection on a residential electric service?
a) grounding conductors
b) bonding conductors
c) identified conductors
d) ungrounded conductors
D: ungrounded conductors
Ref: 290.9
Given: a 40-gallon electric water heater has a nameplate rating of 4,500 watts at
240 volts. What is the MAXIMUM standard size circuit breaker the NEC permits to
protect the water heater?
a) 20 amperes
b) 25 amperes
c) 30 amperes
d) 45 amperes
C: 30 amperes
Ref: 422.11(E)(3); 240.6(A); Current Formula
Sol:
I = P/E
I = 4500 va / 240 volts
I = 18.75 amps x 150 percent
I = 28.1 amperes
If a cable or raceway enters an enclosure such as a meter base, above
uninsulated live parts in a wet location, the fittings used to connect the enclosure
must be _____ for wet locations.
a) identified
b) marked
c) suitable
d) listed
D: listed
Ref: 312.2(A)
In general, the power supply cord to a mobile home shall have a MAXIMUM rating
of _____.
a) 50 amperes
b) 60 amperes
c) 100 amperes
d) 125 amperes
A: 50 amperes
Ref: 550.10(A)
A 150 kVA, single-phase transformer having a secondary voltage of 120/240 is to
be installed at a multi-family dwelling. The current available at the secondary is
_____ amperes.
a) 329
b) 421
c) 625
d) 729

Document information

Uploaded on
April 17, 2024
Number of pages
6
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
magdamwikash23
3.9
(14)
Sold
114
Followers
94
Items
5328
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions