FDNY Fire Life & Safety Director Test #4 Complete Questions And Answers
FDNY Fire Life & Safety Director Test #4 Complete Questions And Answers _________ is the sudden, simultaneous ignition of everything in a room. This is the most dangerous stage of fire development because the heat radiates downward, and intensifies until all combustible items reach their ignition temperatures and burst into flames. Flashover When a fire protection system is completely out of service due to an unplanned condition, what color disk should be placed at the Fire Department Connection? White in the event of fire, medical emergency, or non-fire emergency, the FLS Director must ________________. Report to the Fire Command Center All elevators equipped with firefighter service shall be subjected to a test of phase I and phase II ___________. At least monthly and records kept for 3 years. For elevators operating in phase I firefighter service, if the "emergency stop" button is pressed during recall what action will result? Elevator will continue to the lobby as the emergency stop button is rendered operable. Fogging and fumigation should be performed under the general supervision of a: W-97 Certificate of Fitness holder In the event of an activation of fire alarm, the FLS Director must immediately report to_______. The Fire Command Center Activation of a _______ would initiate phase I emergency elevator recall. Sprinkler water-flow Speakers, horn strobes, and gong bells would be classified as: Audible and visual notification devices Fire drills frequency for Group R-1 (hotels/motels) should be conducted how often? Every three months on each shift Historically, sprinkler systems have been proven to be effective in approximately ________ of structural fires in buildings which were equipped with sprinklers. 96% Upon arrival of the Fire Department the FLS Brigade would be required to report: To the Fire Command Center for additional instructions The list of occupants who request assistance must be maintained at the ___________. Fire Command Center By July 1, 2019, all office buildings ________ feet or more in height are required to install sprinkler systems for the entire building. Any building with voluntarily installed sprinkler systems must also comply with the Fire/Building Code 100 Which of the following statements is most CORRECT regarding the safest way for the fire FLS Brigade to respond to investigate a fire alarm condition on a floor? Initially respond to a floor below the alarm floor, then carefully proceed to the fire floor by means of a safe stairwell. When FDNY arrives in response to a fire/smoke condition, they should expect all of the following to have been done EXCEPT: Alarm reset _________ are designed to open and close as required to provide a source of fresh air or to stop the passage of smoke. Smoke dampers A security guard died during a fire that occurred in a 17-story high-rise hotel in New Orleans, LA in 1987. What actions are recommended in the curriculum that may have prevented him from losing his life and possibly helped allow him to carry out his duties? He should not have entered the fire floor when conditions were severe. He should have immediately closed the door, gone to the nearest safe area and then immediately activated the manual fire alarm station. Which person/entity listed below is responsible for the availability and state of readiness of the Fire FLS Brigade? The Fire Life Safety Director
Written for
- Institution
- FDNY Fire Life & Safety Director
- Course
- FDNY Fire Life & Safety Director
Document information
- Uploaded on
- April 8, 2024
- Number of pages
- 14
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
fdny fire life safety director test 4 complete
Also available in package deal