ACI Concrete Field Testing Technician- Grade I questions with correct answers
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. 3 in. [75 mm] The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] The temperature measuring device shall be calibrated _____, or whenever there is a question of _____. Annually, accuracy The temperature of concrete may be measured in a wheelbarrow. True or False? True The temperature of concrete may be measured in a wall form. True of False Tru
Written for
- Institution
- ACI Concrete Field Testing Technician- Grade I
- Course
- ACI Concrete Field Testing Technician- Grade I
Document information
- Uploaded on
- April 3, 2024
- Number of pages
- 22
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
- aci
- concrete field testing
-
aci concrete field testing technician grade i
-
the sensor of the temperature measuring device sha