Fdny p-99 c of f 2024 Latest Update Correct 100%
What is a general requirement of the location of the installation of a boiler? - ANSWER Adequate clearance from combustile construction What temperature must the materials remain under during combustion? - ANSWER 170 degrees What is a requirement for the access of the boiler? - ANSWER Access for operation and maintenance must not be hazardous What is required upon installation to operate a boiler? - ANSWER Inspection and test resulting in equipment use permit from commissioner How often should a boiler be inspected? - ANSWER Once a year What documentation is required from a certificate holder? - ANSWER Owners annual statement What is required to hydrostatically test upon installation and who should perform these tests? - ANSWER Liquid fuel piping and fuel oil storage tanks by the installing contractor At what pressure should piping be tested? - ANSWER 1/2 max working pressure but less than pressure required for storage tank At what pressure should oil storage tanks be tested? - ANSWER At 1 1/2x max working pressure but never < 25 psi How long should hydrostatic pressure be maintained? - ANSWER Until all joints and connections are inspected for leaks and at 30 minutes have passed Who is responsible for testing gas distribution piping? - ANSWER Installing contractor before closing and operation What is described on instruction cards and where are they located? - ANSWER Care and operation of oil burner located near the equipment. What type of burners require a C of F holder to operate them? - ANSWER Any boiler that is not automatic or requires preheating. What is the license holder responsible for after repair? - ANSWER Inspecting the repairs, and functioning of all control devices and positioning of valves. What type of heat and combustion equipment are required with the air pollution control code? - ANSWER All burners fire with solid, liquid, or gas. Including rubbish burners/incinerators. What temperature are the products of combustion upon exit in low temperature equipment? - ANSWER Less than 600 degrees What temperature are the products of combustion upon exit in medium temperature equipment? - ANSWER 6001000 What temperature are the products of combustion upon exit in high temperature equipment? - ANSWER 1000+ How much cfm of air be capable of per gallon of oil per hour? - ANSWER 36 cfm
Written for
- Institution
- Fdny p-99 c of f
- Course
- Fdny p-99 c of f
Document information
- Uploaded on
- March 19, 2024
- Number of pages
- 6
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
- fdny p 99 c of f 2024
-
fdny p 99 c of f 2024 latest update correct 100
-
what is a general requirement of the location of t
-
what temperature must the materials remain under d