Supervisor NJ Complete Solution Rated A Version.2024
Supervisor NJ Complete Solution Rated A Version.2024Fiber release episode: Means any uncontrolled or unintentional disturbance of ACBM resulting in visible emissions. Air erosion: Means the passage of air over friable ACBM which may result in the release of asbestos fibers. Asbestos debris: Means pieces of ACBM that can be identified by color texture, or composition; or means dust, if the dust is determined by an accredited inspector to be ACM. Operating and maintenance program: means a program of work practices to maintain friable ACM in good condition, ensure clean up of asbestos fibers previously released, and prevent further release by minimizing and controlling friable ACBM disturbance or damage. AHERA (Asbestos Hazardous Emergency Response Act) final air sampling for removal, enclosure, or encapsulation requires that: If 260 linear ft or 160ft^2 it's OK to use PCM (Phase contrast Micros.) If 260 linear ft or 160 ft^2 only use TEM (Transmission Electron Mic.) Federal employees Employees of local education agencies who perform operations and maintenance (O&M), and repair activities involving ACM are protected not by OSHA, but instead - are protected by US-EPA 40CFE763: Worker protection - Final Rule. Notification requirements for demolitions jobs in which ACM will be disturbed. The US-EPA must be notified within 10 working days for large and small jobs. Record keeping requirements for: Objective Data & Employee exposure measurements. The employer shall maintain these records for at least 30 years. Record Keeping Requirements For: Medial Survailance The employer shall maintain these records for the duration of employment plus 30 years. Record Keeping requirements for: Training Records The employer shall maintain these records for one (1) year beyond the last day of employment by that employer. If the fiber exposure levels inside the work area increased from 0.2 f/cc to 2 f/cc what could have caused this increase? ACM was not sufficiently wet. What is considered "sufficiently wet" • sufficiently wet or adequately wet means that sufficient mix or penetrate solution (surfactant) has been added to liquid (water) and applied to the ACM surface so as to prevent the release of particulates. • If visible emissions are observed coming from ACM. Then that material has not been adequately wetted. What is the maximum height of a rolling scaffold in relation to its base The maximum allowed height is four times its base. When asbestos fibers reaches the alveoli, what disease does it produce. It produces fibrosis scarring of the lungs, which is also known as asbestosis. By how many times is the concentration of fibers inside a respirator reduced by if a worker wears a full face - negative pressure respirator? [in] = out/pf = out/50 The concentration is reduced by 50 times. Waste water in New Jersey Must be filtered down to 5 um & then discarded to the sewer system with approval of local authority. It can also be solidified with a polymer (solidification agent), & then discarded as ACM waste. If an employee works 38hrs. During a week, plus 8hrs on Saturday. How much does he make on Saturday if overtime is paid at time and a half, & his regular earnings is $10 per hr? ... A "visitor" walking by the work area suffers an accident. What kind of insurance will protect the owner? General Liability Insurance. Ground Fault Circuit Interruptor (GFCI) is? A device used to prevent electric shock. Where should the GFCI units be connected? GFCI units should be connected at the main power source panel. Tag & lock Out systems: A system to de-energize electrical, hydraulic thermal, or any other energy source to prevent accidental activation of such a system. Glove bags should have the following, except? A screen to control pressure. Why is it not permitted to use glove bags above 150 F ? Because the plastic and the duct tape can come apart. What should be done if an asbestos bag rips or breaks? Keep ACM wet, and put broken bag and waste into another bag. ACM waste: Must be transported in a truck that is separated from the conductors cabin, and its covered with two 2 layers of poly. Which agencies regulate the transportation of ACM waste? US-EPA & US-DOT According to OSHA regulations, What respirator should be used if the concentration were 2 f/cc? Type "C", Pressure demand Can an operation and Maintenance (O&M) worker in the event of an emergency remove ACM equivalent to a large asbestos project?(Large project means 260 linear ft or 160 ft ^2) No, because O&M workers are limited to the removal of only one asbestos bag. What is the last piece of PPE (Personal protection equipment) that the worker puts on before entering the work area? The gloves Where should OSHA signs be placed at? At every entrance to the work area. Where do you store your street cloths? In the clean room The personal decontamination chamber is composed of the following, except? The work area Where do you take your suit off? In the equipment (dirty) room Where do you take off your respirator? In the shower, while taking the shower. A type "C" compression system is used to provide respiratory protection for 12 workers. The compressor has a capacity of 30 CFM, each of the 12 lines extends for 150ft. Workers are complaining of not getting enough air. What could be the problem? The compressor doesn't have enough capacity.
Written for
- Institution
- Asbestos
- Course
- Asbestos
Document information
- Uploaded on
- March 13, 2024
- Number of pages
- 4
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
supervisor nj complete solution rated a version20
-
fiber release episodemeans any uncontrolled or u
Also available in package deal