Amatrol Finale exam 2024 latest update(fully solved&updated)dowload to pass
There Two basic types of timers Non-retentive and retentive An)_____non-retentive timer turns on its output as soon as its input turns true. Off-Delay Which type of timer has a reset input? Retentive Which type of timer does not maintain its elapsed time if its input resets while it is timing? Non-retentive PLC timer instructions are instructions used to provide time-based control logic. internal output An)_____timer turns on its output after the elapsed time reaches the preset time. on-delay This is the name assigned to the instruction Timer name The amount of time the instructions IN input must be true before the Q output is set Preset time The amount of time that the instruction's IN input has been true Elapsed time This is the input that is used to enable the timer instruction IN input This is the output that is turned on when the elapsed time equals or exceeds the preset time Also this is the output that is turned on when IN input turn true Also this is the output that is turned on when the CV is equal to the PV Q output PLC ____ instructions are internal output instructions that are used to provide time delays in the logic in a PLC program. timer When a timer times out, it can make NO and NC contact instructions on other rungs change ___. States A(n) ___ timer does not retain its elapsed time if its input turns false. Its elapsed time resets to zero when its input turns false. non-retentive A(n) ___timer retains is elapsed time when its input turns false. The elapsed time can only be reset by a separate reset input. retentive A non-retentive on-delay timer instruction turns on its output after its ___ has reached its preset time. elapsed time Because it is non-retentive, a TON timer's elapsed time resets to zero when its input turns ___ . false This is the input used to reset instructions RST Input A non-retentive off-delay timer instruction turns on its output immediately when the___ input turns true. IN The ET of a non-retentive off-delay timer does not increase until the IN input tums ___. false A non-retentive timer's elapsed time resets to zero if the IN input tums true while the ET is ___. increasing A retentive on-delay timer (RTO) instruction turns on its output after its ___ has reached its preset time. elapsed time Because it is retentive, the RTO timer's elapsed time does not ___ to zero when the input turns false. reset The RTO timer instruction will not reset until the ___ input turns true. RST PLC ___ instructions are internal output instructions that are used to provide count based logic in a PLC program. counter A counter instruction changes its ___when its input turns true. count value (CV) A(n) ___ instruction increases its count value (CV) by one each time its CU input turns from false to true. count up (CTU) A count up (CTU) instruction turns on its ___ output when the count value (CV) has reached the preset value (PV). Q A(n)___instruction decreases its count value (CV) by one each time its CD input turns from false to true. count down (CTD)
Written for
- Institution
- Amatrol
- Course
- Amatrol
Document information
- Uploaded on
- March 10, 2024
- Number of pages
- 5
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
amatrol finale exam 2024 latest update
Also available in package deal