Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

ACI GRADE 1 FIELD TESTING CERTIFICATION PRACTICE TEST – IRVING GRADED A+

Rating
-
Sold
-
Pages
9
Grade
A+
Uploaded on
15-02-2024
Written in
2023/2024

ACI GRADE 1 FIELD TESTING CERTIFICATION PRACTICE TEST – IRVING GRADED A+ For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (T or F) - -False (2-5 minutes) The temperature measuring device must be accurate to within 0.1 degree. (T or F) - - The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of _____ to _____ degree F ( ______ to ______ degree C) - -30 to 120 degree F ( 0 to 50 degree C) A composite sample is not needed if only the temperature test is being run. (T or F) - -True The temperature of fresh concrete in a placement must be measured by inserting a thermometer into the top six inches of concrete. (T or F) - -False (3 in.) The temperature of the concrete is recorded to the nearest ______ degree F (______ degree C) - - 1 degree F (0.5 degree C) ASTM C1064 states the container used to measure temperature of concrete must be large enough to provide at least 5 inches of concrete around the sensor. (T or F) - - Calibrate the temperature measuring device at least __________, or whenever there is a question of accuracy. - -Annually After the thermometer is placed in the concrete: - -Gently press concrete around the thermometer According to ASTM C1064, what is one reason to take the temperature of concrete? - -Verify conformance It is allowable to remove the temperature measuring devices from the freshly mixed concrete to read the temperature if you cannot see the reading. (T or F) - -False The maximum allowable time between obtaining the first and last portions of the composite sample may not exceed 5 minutes. (T or F) - -False Start molding specimens for strength tests within 30 minutes after fabricating the composite sample. (T or F) - -False (15 mins) The composite concrete sample must be protected from sun, wind, contamination and rapid evaporation. (T or F) - -False (Contamination and rapid evaporation)

Show more Read less
Institution
ACI GRADE 1 FIELD TESTING CERTIFICATION
Course
ACI GRADE 1 FIELD TESTING CERTIFICATION

Content preview

ACI GRADE 1 FIELD TESTING CERTIFICATION PRACTICE TEST – IRVING
GRADED A+


For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete
sample a minimum of 5 minutes or until the temperature reading stabilizes. (T or F) - ➡-False (2-5
minutes)



The temperature measuring device must be accurate to within 0.1 degree. (T or F) - ➡-



The temperature measuring device shall have a capacity of measuring temperature of freshly mixed
concrete throughout a range of _____ to _____ degree F ( ______ to ______ degree C) - ➡-30 to 120
degree F ( 0 to 50 degree C)



A composite sample is not needed if only the temperature test is being run. (T or F) - ➡-True



The temperature of fresh concrete in a placement must be measured by inserting a thermometer
into the top six inches of concrete. (T or F) - ➡-False (3 in.)



The temperature of the concrete is recorded to the nearest ______ degree F (______ degree C) - ➡-
1 degree F (0.5 degree C)



ASTM C1064 states the container used to measure temperature of concrete must be large enough to
provide at least 5 inches of concrete around the sensor. (T or F) - ➡-



Calibrate the temperature measuring device at least __________, or whenever there is a question of
accuracy. - ➡-Annually



After the thermometer is placed in the concrete: - ➡-Gently press concrete around the thermometer



According to ASTM C1064, what is one reason to take the temperature of concrete? - ➡-Verify
conformance

, It is allowable to remove the temperature measuring devices from the freshly mixed concrete to read
the temperature if you cannot see the reading. (T or F) - ➡-False



The maximum allowable time between obtaining the first and last portions of the composite sample
may not exceed 5 minutes. (T or F) - ➡-False



Start molding specimens for strength tests within 30 minutes after fabricating the composite sample.
(T or F) - ➡-False (15 mins)



The composite concrete sample must be protected from sun, wind, contamination and rapid
evaporation. (T or F) - ➡-False (Contamination and rapid evaporation)



If the concrete contains aggregates larger than those that are appropriate for a size of mold or
equipment used, the sample should be wet-sieved before making the test. (T or F) - ➡-False (wet
screened)



The composite sample not be remixed before beginning any tests. (T or F) - ➡-False



Sampling should normally be performed, as the concrete is discharged from the mixer. (T or F) - ➡-
True



ASTM Method C172 includes the sampling from stationary mixers, paving mixers, truck mixers,
agitators, and non-agitating equipment. (T or F) - ➡-True



After sampling is completed, start the tests for slump and air content within: - ➡-None of the above
(5 mins)



In any case, do not obtain samples until: - ➡-All the water and admixtures have been added to the
concrete



No samples shall be taken before ______ or after ______ of the batch has been discharged. - ➡-



When strength tests are to be made, the minimum size of the composite sample shall be: - ➡-1
cubic foot

Written for

Institution
ACI GRADE 1 FIELD TESTING CERTIFICATION
Course
ACI GRADE 1 FIELD TESTING CERTIFICATION

Document information

Uploaded on
February 15, 2024
Number of pages
9
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$5.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
AcademiaGiant

Get to know the seller

Seller avatar
AcademiaGiant NCSU
View profile
Follow You need to be logged in order to follow users or courses
Sold
3
Member since
2 year
Number of followers
2
Documents
294
Last sold
1 year ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions