100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Massachusetts Unrestricted CSL Practice and review questions And Answers With Complete Verified Solution

Rating
3.0
(1)
Sold
1
Pages
26
Grade
A+
Uploaded on
02-12-2023
Written in
2023/2024

Massachusetts Unrestricted CSL Practice and review questions And Answers With Complete Verified Solution A child day care facility that provides care on a 24 hour basis for more than five children two years nine months of age or less shall be classified as Use Group _____ ? 1-4 IBC - section 308.5.2 - mass amendments When conducting strength test of concrete, test are not required when the volume of concrete is less than ____ cubic yards, and evidence of satisfactory strength is submitted to and approved by the building official 10 IBC - section 1905.6.2 - exceptions-mass amendments The minimum amount of glazing area required for a habitable room in a single family dwelling that measures 20 ft. x 30 ft. is ____ square feet 48 IRC - section R303.1 Which type of construction best describes a structure consisting of exterior walls constructed of noncombustible materials and the interior building elements are of solid or laminated wood without concealed spaces? Type IV IBC - section 602.4 A foundation that has a finished grade that slopes away form the building must be a minimum of ____ inches lower at a point ____ feet away from the face of the wall 6, 10 IBC - section 1804.3 Footings for masonry chimneys shall extend a minimum of ____ inches beyond the face of the foundation or support wall on all sides 6 IBC - section 2113.2 The connection between a pressure treated deck ledger and a 2 inch nominal lumber band joist in a single family dwelling, bearing on a sill plate or wall, shall be constructed with a minimum ____ inch lad screw or bolt 1/2 IRC - section R502.2.2.1 What is the clearance required from the opening of a fireplace to combustibles such as trim and mantels placed directly on the front of the fireplace? 6 inches IBC - section 2111.11 - exception 4 What is the minimum required flue size for a rectangular flue in a chimney serving a fireplace for a single family dwelling with an opening of 500 square inches with a height of 15 feet? 8 x 12 IRC - figure R1003.15.2 Which of the following is NOT an effective method of preventing efflorescence? A. forming good mortar joints B. using high-early strength cement C. stocking materials off of the ground D. covering materials at all times Using high-early strength cement class handouts What is the maximum temperature a flue lining used in a residential-type appliance in a masonry chimney, in a single family dwelling, must resist? 1,800 degrees F IRC - section R1003.11.1 #4 Which of the following is NOT true regarding the placement of masonry units in a single family dwelling? A. mortar shall be plastic B. surfaces shall be clean and free of deleterious material C. units where initial bond is broken shall be removes and relaid D. deep furrowing of bed joints Deep furrowing of bed joints IRC - section 607.2.2 What is the minimum required depth of fireplace fireblocking between wood joists, beams or headers? 1 inch IBC - section 2111.12 What is the minimum required thickness of a mortar joint in a masonry unit wall in a one or two family dwelling? 3/8 inch IRC - section R607.2.1 In a single family dwelling with an 8:12 roof pitch and a cricket hight of 12 inches, what is the width of the cricket? 36 inches IRC - table R1003.20 Which of the following is NOT true regarding masonry chimneys in a one or two family dwelling? A. chimneys may support additional loads if designed to do so B. must extend a minimum of 3 feet above highest point where passing through roof C. chimneys may be unlined D. walls must be a minimum of 4 inches in thickness Chimneys may be unlined IRC - section R1003.11 Which of the following is NOT true regarding second-hand masonry units? A. old mortar must be cleaned from unit B. units must be free of cracks and other defects C. units must conform to requirements of new units D. may not be used under any circumstances May not be used under any circumstances IBC - section 2103.7 What is the diameter of a #6 re-bar? 3/4 inch handouts What is the reaction between water and portland cement which causes it to harden? Heat of hydration handouts When used as an ingredient in shotcrete, can course aggregate have a diameter of 7/8 inch? No IBC - section 1913.3 What is the minimum required thickness of a parging coat used to damproof the surface of masonry unit walls? 3/8 inch IBC - section 1805.2.2.1 Can an eight foot high concrete foundation wall of plain concrete be 8 inches thick then the maximum depth of unbalanced fill is 6 feet?

Show more Read less
Institution
Massachusetts Unrestricted CSL
Course
Massachusetts Unrestricted CSL










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Massachusetts Unrestricted CSL
Course
Massachusetts Unrestricted CSL

Document information

Uploaded on
December 2, 2023
Number of pages
26
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Reviews from verified buyers

Showing all reviews
8 months ago

3.0

1 reviews

5
0
4
0
3
1
2
0
1
0
Trustworthy reviews on Stuvia

All reviews are made by real Stuvia users after verified purchases.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
MedTestPro Chamberlain College Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
56
Member since
3 year
Number of followers
30
Documents
4368
Last sold
1 week ago
Get instant access to a wide range of educational resources, practice quizzes, and study materials designed to empower nursing students. Enhance your knowledge, ace your exams, and build confidence with medtestpro's comprehensive collection of text-based

Get instant access to a wide range of educational resources, practice quizzes, and study materials designed to empower nursing students. Enhance your knowledge, ace your exams, and build confidence with medtestpro's comprehensive collection of text-based nursing resources.

3.4

5 reviews

5
1
4
1
3
2
2
1
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions