What type of appliances are constructed so that all air for combustion is derived directly from the outdoors through one duct or pipe, and all flue gases are discharged to the outdoors through another duct or pipe? - CORRECT ANS Direct Vent Name plates are required when installing a _____ appliance. - CORRECT ANS Listed Name two factors you must consider when selecting an appliance for a given application - CORRECT ANS Venting & combustion air What method for calculating needed combustion air is used when the air infiltration is unknown? - CORRECT ANS Standard calculation method When determining the air infiltration rate using KAIR method, the following must be determined: a) Calculate ACH For building b) Size combustion air openings c) Determine building parameters d) all of the above - CORRECT ANS D - all of the above Which method is used when supplying additional air to a structure by creating two permanent openings in a single room, one on top an done on bottom, each 12" from the ceiling or floor? - CORRECT ANS Two-openings method The three sources for supplying additional air to a structure that is found to have an inadequate air supply are indoor air, outdoor air and _______ - CORRECT ANS Combination indoor and outdoor air The three types of venting systems are natural draft venting, direct venting and ________ draft venting - CORRECT ANS Mechanical In a sealed combustion direct vent appliance: a) combustion air is separate from where the appliance is located b) combustion air is obtained from and discharged to the outdoors c) venting is not required d) both a and b - CORRECT ANS D - both a & b A typical natural draft venting system has several components, some of which include: a) draft hood b) exhaust fan c) electrical interlock d) all of the above - CORRECT ANS a - draft hood this common type of vent material used in a natural draft venting system is made of double-wall construction, forms a continuous flue passageway from a gas appliance to a vent termination and heats up quickly - CORRECT ANS Type B-vent A single-wall venting cannot be used under which of the following circumstances: a) outdoors in regions where the 99% winter design temperature is below 32F b) In an attic c) In a wall or floor c) all of the above - CORRECT ANS d-all of the above A vent connector must be routed to a vent using the ______ possible route. - CORRECT ANS Shortest

Show more Read less
Course
CETP









Whoops! We can’t load your doc right now. Try again or contact support.

Document information

Uploaded on
November 9, 2023
Number of pages
5
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • cetp
  • updated cetp review exam

Content preview

CETP Review Exam 2023 Questions
and Answers with complete solution

What type of appliances are constructed so that all air for combustion is derived
directly from the outdoors through one duct or pipe, and all flue gases are
discharged to the outdoors through another duct or pipe? - CORRECT ANS
Direct Vent
Name plates are required when installing a _____ appliance. - CORRECT ANS
Listed
Name two factors you must consider when selecting an appliance for a given
application - CORRECT ANS Venting & combustion air
What method for calculating needed combustion air is used when the air infiltration is
unknown? - CORRECT ANS Standard calculation method
When determining the air infiltration rate using KAIR method, the following must be
determined:
a) Calculate ACH For building
b) Size combustion air openings
c) Determine building parameters
d) all of the above - CORRECT ANS D - all of the above
Which method is used when supplying additional air to a structure by creating two
permanent openings in a single room, one on top an done on bottom, each 12" from
the ceiling or floor? - CORRECT ANS Two-openings method
The three sources for supplying additional air to a structure that is found to have an
inadequate air supply are indoor air, outdoor air and _______ - CORRECT ANS
Combination indoor and outdoor air
The three types of venting systems are natural draft venting, direct venting and
________ draft venting - CORRECT ANS Mechanical
In a sealed combustion direct vent appliance:
a) combustion air is separate from where the appliance is located
b) combustion air is obtained from and discharged to the outdoors
c) venting is not required
d) both a and b - CORRECT ANS D - both a & b
A typical natural draft venting system has several components, some of which
include:
a) draft hood
b) exhaust fan
c) electrical interlock
d) all of the above - CORRECT ANS a - draft hood
this common type of vent material used in a natural draft venting system is made of
double-wall construction, forms a continuous flue passageway from a gas appliance
to a vent termination and heats up quickly - CORRECT ANS Type B-vent
A single-wall venting cannot be used under which of the following circumstances:
a) outdoors in regions where the 99% winter design temperature is below 32F
b) In an attic
c) In a wall or floor
c) all of the above - CORRECT ANS d-all of the above
A vent connector must be routed to a vent using the ______ possible route. -
CORRECT ANS Shortest

, CETP Review Exam 2023 Questions
and Answers with complete solution

When sizing multiple Category I appliances to an existing venting system, which of
the following must be considered prior to installation:
a) whether all appliances are designed for use with a common venting system
b) whether the existing venting system has the capacity to handle additional
appliances
c) whether the existing system has the proper venting materials needed for the
added appliances
d) all of the above - CORRECT ANS d - all of the above
An ________________ between a mechanical draft system and an appliance gas
control valve will stop the flow of gas to the main burner when the draft system is not
operating - CORRECT ANS Electrical interlock
To select the appropriate regulator for a given piping system, you must consider
________________ - CORRECT ANS Pipe Size
When venting a line regulator, all of the following conditions should exist EXCEPT:
a) vent line must be at least the same size as the regulator vent connection
b) no vent line is required when using a regulator incorporating a vent limiter
c) regulator vents must terminate at least 3 ft from a source of ignition
d) you may vent a line regulator to an appliance flue or exhaust system -
CORRECT ANS D
Which of the following pipes will supply the least amount of BTU/hr?
a) smaller pipe operating at a higher pressure
b) a larger pipe operating at a lower pressure
c) a larger pipe at a higher pressure
d) a smaller pipe operating at a lower pressure - CORRECT ANS D
If you must install gas piping in a concealed location, you may not use which of the
following connecting materials?
a) threaded tees
b) tubing fittings
c) threaded couplings
d) threaded elbows - CORRECT ANS B - tubing fittings
The maximum design operating pressure for piping systems located inside buildings
cannot exceed ____________ except in a limited number of circumstances. -
CORRECT ANS 5 psi
What are some of the variables you will need to know to determine the appropriate
pipe size for given system using the longest length method? - CORRECT ANS
Gas demand and pipe length
The "branch length method" is used to size which of the following pipes:
a) Copper tubing
b) CSST
c) Steel
d) all of the above - CORRECT ANS d - all of the above
The hybrid pressure method is typically used in 2-psi vapor distribution systems or
other __________ gas pressure piping systems - CORRECT ANS Higher
Which type of appliance is designed to work with either propane or natural gas? -
CORRECT ANS Convertible

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TestBankcenter NURSING
View profile
Follow You need to be logged in order to follow users or courses
Sold
96
Member since
2 year
Number of followers
21
Documents
1239
Last sold
1 month ago
TestbankCenter

We offer a wide selection of exams and study guides from a variety of courses and subjects, all created by experts. Our notes are comprehensive, well-organized, and easy to understand, so you can focus on learning and achieving your academic goals.

3.8

24 reviews

5
9
4
7
3
3
2
5
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions