100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

EEG BOARD Prep Part 1 (Answered) Verified Solution MUltiple Choice Questions And Answers

Rating
-
Sold
-
Pages
41
Grade
A+
Uploaded on
14-01-2023
Written in
2022/2023

EEG BOARD Prep (Part 1) The basic unit for measuring current flow is: a. atomic weight b. Coulomb c. Volt d. Ampere d. ampere The basic unit of resistance is: a. Ohm b. Coulomb c. Ampere d. Volt a. ohm Which of the following is NOT a valid expression of Ohm's Law: a. R=EI or (R=VI) b. E=IR or (V=IR) c. I=E/R or (I=V/R) d. R=E/I or (R=V/I) a. R=EI or (R=VI) Which of the following is NOT a unit for measuring alternating frequencies: a. cycles per second b. volts c. hertz d. kilocycles b. volts Which of the following describes the action of a capacitor? a. opposes changes in current flow b. converts A/C to D/C c. creates a direct current resistance d. stores energy d. stores energy A circuit that allows some frequencies to pass through it, while others are blocked is a: a. resistor b. transistor c. filter d. reactor c. filter A combination of electronic components designed to increase the power, voltage or current of a signal: a. amplifier b. line filter c. master gain control d. sensitivity a. amplifier A small fluctuating output recorded by the EEG instrument even when there is no input signal is called: a. output voltage b. linear distortion c. 60Hz interference d. noise d. noise The EEG amplifier is designed so that when input 1 is more negative than input 2, the deflection will be upward Common mode rejection is: a. the ability of an amplifier to cancel out ECG artifact b. the characteristic of an amplifier that rejects external interference c. is dependent on the sampling rate d. controlle by the 60-cycle notch filter b. the characteristic of an amplifier that rejects external interference Which of the following is most attenuated by a low frequency filter of 1 Hz? a. 0.5 Hz b. 5.0 Hz c. 10.0 Hz d. 0.1 Hz d. 0.1 Hz Time constant is defined as the time required for the deflection to fall (decay): a. to 47% of the peak deflection b. 57% of the peak deflection c. 77% of the peak deflection d. to 37% of the peak deflection d. to 37% of the peak deflection An EEG record has 3/sec spike & wave discharges. Both the spike and the slow wave have voltages of 100uV. If this discharge is recorded with a LFF of 5Hz and a sensitivity of 10uV/mm, what would be the deflection of the spike and the wave? a. spike 10mm & wave 6mm b. spike 6mm & wave 10mm c. spike 10mm & wave 10mm d. spike 6mm & wave 6mm a. spike 10mm wave 6mm A high frequency setting of 35Hz would attenuate 50Hz muscle activity by approximately what percentage: a. 10% b. 20% c. 40% d. 100% c. 40% According to ACNS Guidelines, Recording on Clinical EEG on Digital Media requires monitors to have between 25 & 35mm/second horizontal scaling and a: a. maximum of 1,000 data points/second to accurately display EEG on the monitor screen b. minimum of 100 data points/second to accurately display EEG on the monitor screen c. maximum of 100 data points/second to accurately display EEG on the monitor screen d. minimum of 1,000 data points/second to accurately display EEG on the monitor screen b. MINIMUM of 100 data points/second to accurately display EEG on the monitor screen The filters creating a very narrow band pass that should RARELY be used clinically are: a. LFF 5.0Hz & HFF 70Hz b. LFF 5.0Hz & HFF 15Hz c. LFF 0.1Hz & HFF 70Hz d. LFF 0.1Hz & HFF 15Hz b. LFF 5.0Hz & HFF 15Hz During the recording of cerebral activity, the calibration input voltage is changed from 50uV to 100uV...what will be the result? a. no effect on the activity being recorded b. a two-fold increase in amplitude c. a one-half reduction of amplitude d. clipping of the waveform a. no effect on the activity being recorded A spike is printed out on paper and measures 16mm peak to peak, the sensitivity of the instrument is 7uV/mm and a calibration signal of 50uV causes a deflection of 7.1mm...what is the voltage of the spike? a. 1.2uV b. 112uV c. 12uV d. 24uV b. 112uV What input voltage is necessary to give a calibration deflection between 5 and 10mm if the sensitivity is 30uV/mm? a. 10uV b. 50uV c. 100uV d. 200uV d. 200uV According to the ACNS Guidelines 2006, the minimum sampling rate for EEG data, should be at least how many times the highest HFF setting: a. two b. three c. four d. ten b. three In a record with 10Hz alpha activity, when the display epoch is changed from 10 seconds/display screen to 20 seconds/display screen, the frequency of the activity will be: a. 5Hz b. 15Hz c. 20Hz d. 10Hz d. 10 Hz In a DC calibration wave, if in channel-B compared to channel-A, is "slower", what instrument change would have been made to channel B: a. display epoch length b. decrease LFF c. increase HFF d. sensitivity b. decrease LFF Guidelines for recording digital EEG are written by: a. the American Society of Electroneurodiagnostic Technologist (ASET) b. the American Academy of Neurology (AAN) c. the American Clinical Neurophysiology Society (ACNS) d. the Organization of Societies of Electrophysiological Technology (OSET) c. the American Clinical Neurophysiology Society (ACNS) The term RAM means: a. read only memory used for archiving data b. the amount of data that can be stored on a rewritable CD c. the amount of data that can be stored on a DVD d. temporary memory storage that is critical to rapid computer operations d. temporary memory storage that is critical to rapid computer operations Three basic computer PORTS are: a. intranet, internet & extranet b. internal, external & bifid c. serial, paradoxical & US d. serial, parallel & USB d. serial, parallel & USB The best metals for clinical EEG recording are: a. gold-plated lead, nickel or silver b. silver-silver chloride, platinum or gold c. tin, copper, or silver-silver chloride d. stainless steel, platinum or silver b. silver-silver chloride, platinum or gold Which electrodes do NOT record directly from the brain? a. depth b. sub-dermal c. subdural d. epidural b. sub-dermal

Show more Read less
Institution
EEG BOARD Prep
Course
EEG BOARD Prep











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EEG BOARD Prep
Course
EEG BOARD Prep

Document information

Uploaded on
January 14, 2023
Number of pages
41
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Topscorer1 South University
View profile
Follow You need to be logged in order to follow users or courses
Sold
248
Member since
4 year
Number of followers
207
Documents
7291
Last sold
4 days ago
TOPSCORER1

Expert Study Solutions | Nursing, Business, Accounting & More! Looking for top-quality study materials to excel in college or university? You're in the right place! I provide highly graded, almost A+ solutions across various subjects, including Nursing (my main expertise), Business, Accounting, Statistics, Chemistry, Biology, and many more. ✅ Accurate & Well-Researched Guides ✅ Comprehensive Solutions for Better Grades ✅ Student-Friendly Approach & Full Support ✅ Satisfaction Guaranteed – Refund Available if Not Satisfied I’m committed to helping students succeed by providing reliable, high-quality academic resources. Let’s boost your grades together!

Read more Read less
3.8

40 reviews

5
22
4
5
3
4
2
0
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions