1. Strobe Coverage
Consider a room, which is 40' square. How many 15cd wall-
mounted strobes are required to adequately cover this space?

 Correct Answer: 4

A 40' x 40' room generally requires four wall-mounted strobes to
meet spacing requirements.

2. Strobe Testing Frequency
what is the testing frequency of a strobe?

 Correct Answer: Annually

3. Corridor Strobe Candela rating
In a corridor application, visible appliances shall be rated not less
than ____ cd.

 Correct Answer: 15

4. Household System Battery Recharge
Consider a household fire alarm system where the primary power

,is provided by a circuit that can be switched off by means other
than a circuit breaker. The battery must be recharged in:

 Correct Answer: 4 hours

5. Detector Drift Compensation
Where automatic drift compensation of detectors is provided, the
control unit shall identify the affected detector when the
compensation limit has been reached.

 Correct Answer: (Statement is correct as per NFPA 72)

6. Smoke Detector Spacing in a Corridor
A fire alarm system requires the use of smoke detectors in a
corridor. The corridor is 10' wide and 120' long. The ceiling is
smooth and flat and 10' high. What is the minimum number of
smoke detectors in the corridor?

 Correct Answer: 3

NFPA 72 allows for smoke detectors to be spaced up to 30' apart
in a corridor. A 120' corridor would require at least 3 detectors.

7. Detector Spacing with Beams
The fire alarm system design for a room called for smoke detector
spacing based on a smooth flat ceiling. Upon inspecting the
room, it is determined that the ceiling has beams. The beam
spacing is less than 40% of the ceiling height. NFPA 72 permits
smooth ceiling spacing in the direction parallel to the beams and
____ spacing in the direction perpendicular to the beams.

 Correct Answer: One half smooth

,8. Duct Detector Requirements
The working drawings for a fire alarm system show that 2 duct
detectors are required. The building is a single story with 4 HVAC
units (1-5,000 cfm, 1-4,000 cfm, 1-3,000 cfm, 1-2,000 cfm). How
many duct detectors are required?

 Correct Answer: 2

The question states the drawings specify 2 detectors; the number
of units does not change this requirement.

9. Fire Alarm System Revision Documentation
when an addition is made to a fire alarm system after the initial
installation, the addition shall be recorded on a revised version of
the original completion documents. The revised record of
completion document shall include:

 Correct Answer: a. the revision date

10. Record of Completion Documentation
The record of completion documentation shall be completed by
the:

 Correct Answer: a. contractor who installed the system

11. Battery Charging Installation Location
Battery charging installations shall be located in areas designated:

 Correct Answer: a. and marked

12. Carbon Monoxide Signal Priority
Carbon monoxide signals shall take precedence over:

 Correct Answer: Trouble and Supervisory signals

, 13. FACP Software Protection
All software and firmware that pertain to the FACP of a protected
premises fire alarm system shall be protected from:

 Correct Answer: C. unauthorized changes

14. Elevator Recall Smoke Detectors
Smoke detectors used to recall the elevator for fire fighters'
service shall:

 Correct Answer: a. be connected to the building fire alarm
system

15. Emergency Control Function Interface Devices
Emergency control function interface devices shall be located
within ____ of the element controlling the emergency control
function.

 Correct Answer: 3 ft

16. Soil Classification (USCS)
According to ASTM D2487, a soil is classified as fine-grained when
more than what percentage passes the No. 200 sieve?

 Correct Answer: B) 50%

Per ASTM D2487 (USCS), soils with 50% or more passing the No.
200 sieve are considered fine-grained.

17. Soil Type Identification
You are inspecting a construction site and notice that the soil
appears to be a fine-grained, cohesive material with good bearing
capacity. What type of soil is this likely to be?

Document information

Uploaded on
August 16, 2026
Number of pages
53
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$21.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
3
Followers
0
Items
387
Last sold
6 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions