New Mexico Low Voltage Journeyman ES3J EXAM QUESTIONS
AND CORRECT VERIFIED SOLUTIONS LATEST UPDATE THIS
YEAR – JUST RELEASED
New Mexico Low Voltage Journeyman ES3J Exam Guide & Practice Questions
10-Line Exam Coverage in Points Form
1. Licensing & Regulations – New Mexico Construction Industries Division (CID)
administers licensing; ES3J license covers sound, intercommunication, alarm systems,
and systems 50 volts and under ; reciprocity exists with AK, AR, CO, ID, MT, NE, OK, SD,
TX, and WY for journeyman certificates ; license valid for 3 years ; 16 hours continuing
education required per renewal cycle (8 hours code changes, 8 hours industry-related) ;
examination services provided by PSI .
2. NEC Code Requirements – Exam based on 2020 NEC; grounding and bonding
requirements (NEC Articles 250, 800); cable installation in plenums (NEC 300-34);
working space requirements (48 inches minimum); conduit fill calculations (40% fill with
three conductors) ; Class 1, 2, and 3 circuit distinctions (NEC 725) .
3. Fire Alarm Systems – NFPA 72 governs fire alarm installation, testing, and maintenance ;
power-limited fire alarm circuits (PLFA) distinctions ; notification appliance
synchronization (strobes flash 1-2 flashes per second simultaneously) ; heat detector
spacing (50 feet within family units) ; smoke detector requirements ; firestopping for
fire-rated assemblies .
4. Communications & Low-Voltage Cabling – NEC 800 covers communications circuits;
cable voltage rating minimum 300 volts ; Cat6 T568B wiring standard; minimum
separation 6 feet between communication cables and lighting conductors ;
communications box grounding conductor minimum 14 AWG ; antenna grounding
conductor minimum 10 AWG ; optical fiber cables under 50 feet from point of entry not
required to be listed .
5. Grounding & Bonding – Green wire function in manufactured homes ; grounding
provides safe path for fault current and prevents shock ; bonding conductors must be
appropriately sized and corrosion-resistant ; Ufer ground (concrete-encased electrode) ;
minimum grounding rod length for under 50 volts ; gas pipe not acceptable as ground
electrode .
6. Power Calculations & Circuit Protection – Ohm's law applications (V = I × R); power
formula (P = V × I); Class 1 power-limited circuit maximum 1000 VA; Class 2 circuit
maximum ampacity for 18 AWG copper: 5 amps ; transformer overcurrent protection
sizing (250% for same input/output voltage) ; continuous load definition (3 hours or
more) .
, Page 2 of 132
7. Installation & Wiring Methods – Minimum clearance to edge of wood stud for wire
hole: 1 ¼ inches ; separation between Class 1 and Class 2/3 circuits: ¼ inch ; warning
tape 12 inches above conduit buried 18 inches below grade ; cable support intervals ;
pull boxes for splices and cable pulling .
8. Special Systems & Equipment – CCTV systems, access control, intercom; PoE (Power
over Ethernet) applications – IEEE 802.3af delivers 15.4 W, device receives ~12.95 W ;
Class 3 circuits (30V DC, 100VA) for signaling devices ; Class 2 wiring for low-voltage
sensors ; fiber optics immune to electromagnetic interference ; rectifiers convert AC to
DC .
9. Safety & Testing – Lockout/tagout (LOTO) devices must be rated for voltage and
environment ; proper PPE for ladder work: hard hat, safety glasses, steel-toe boots ;
insulation resistance testing ; grounding electrode system resistance testing ; surge
protectors for lightning protection ; no minimum OSHA approach distance for ≤50V .
10. Exam Logistics – 50 questions, 145-minute time limit ; PSI testing format ; study
resources include NEC Code, NFPA 72, and practice exams ; minimum 70% correct
required to pass ; closed-book format ; calculator may be provided .
50 Practice Questions with Rationales
Question 1
Under New Mexico regulations, what is the maximum voltage scope for an ES-3J licensee?
A) 120V
B) 240V
C) 50V or less
D) 600V
Correct Answer: C
, Page 3 of 132
Rationale: The ES-3J license in New Mexico limits the scope to systems operating at 50 volts or
less, emphasizing safety and specialization in low-voltage special systems such as sound,
intercommunication, alarm systems, and similar applications under this threshold .
Question 2
What is the minimum separation required between communication cables and lighting
conductors?
A) 2 feet
B) 4 feet
C) 6 feet
D) 8 feet
Correct Answer: C
Rationale: NEC requires a minimum separation of 6 feet between communication cables and
lighting conductors to prevent electromagnetic interference and ensure safety .
Question 3
Which NFPA standard covers the requirements for fire alarm systems?
A) NFPA 70
B) NFPA 72
, Page 4 of 132
C) NFPA 70E
D) NFPA 101
Correct Answer: B
Rationale: NFPA 72 specifies the installation, testing, and maintenance of fire alarm and
signaling systems. This is a critical reference for the ES3J exam .
Question 4
What is the minimum size grounding conductor for communications circuits?
A) 18 AWG
B) 16 AWG
C) 14 AWG
D) 10 AWG
Correct Answer: C
Rationale: NEC 830.100(A)(3) requires a minimum 14 AWG grounding conductor for
communications circuits to ensure adequate fault current capacity .
Question 5
When a cable is installed in an area above a suspended ceiling that contains completely
enclosed air ducts, what term identifies this location?
A) Plenum