Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 3 out of 29 pages
Exam (elaborations)

Certified EKG Technician (CET) Mock Examination – Comprehensive ECG/EKG Practice Questions with Rationales

Document preview thumbnail
Preview 3 out of 29 pages

Certified EKG Technician (CET) Mock Examination – Comprehensive ECG/EKG Practice Questions with Rationales

Content preview

Certified EKG Technician (CET) Mock Examination
– Comprehensive ECG/EKG Practice Questions
with Rationales
1. When performing a standard 12-lead EKG, where should the technician place the V4

electrode?

A. Fourth intercostal space, right sternal border


B. Fourth intercostal space, left sternal border


C. Fifth intercostal space, midclavicular line


D. Fifth intercostal space, anterior axillary line


Correct Answer: C


Explanation: The V4 electrode is correctly placed at the fifth intercostal space at the

midclavicular line. This position is critical because it captures the electrical activity at the

apex of the heart. Technicians must avoid placing electrodes directly on bone or over

breast tissue, as this can impede signal quality or lead to inaccurate readings.


2. An EKG technician notices a ‘sawtooth’ pattern in the baseline between QRS complexes.

This is characteristic of which rhythm?

A. Atrial Fibrillation


B. Atrial Flutter


C. Ventricular Tachycardia

,D. Junctional Rhythm


Correct Answer: B


Explanation: Atrial Flutter is defined by rapid, regular atrial depolarizations that create a

characteristic ‘sawtooth’ or ‘F-wave’ pattern. This occurs when an electrical circuit travels

in a loop within the atrium, usually at a rate of 250-350 beats per minute. Recognizing this

pattern is vital for stroke prevention, and candidates should avoid confusing it with the

chaotic, irregular baseline of atrial fibrillation.


3. A patient is experiencing a somatic tremor artifact during an EKG. Which action should the

technician take to resolve this?

A. Check the lead wires for cracks or breaks


B. Move the patient’s limbs away from the trunk


C. Provide a blanket if the patient is shivering


D. Unplug nearby electrical equipment


Correct Answer: C


Explanation: Somatic tremor artifacts are caused by involuntary muscle movement, such

as shivering or Parkinsonian tremors. Providing a blanket to a cold patient reduces muscle

tension and eliminates the artifact, leading to a clearer tracing. Technicians should not

confuse this with AC interference, which requires moving electrical cables or equipment.

, 4. Which of the following heart rates is calculated using the 1500 method if there are 20 small

boxes between two R waves?

A. 60 bpm


B. 150 bpm


C. 100 bpm


D. 75 bpm


Correct Answer: D


Explanation: The 1500 method is the most precise way to calculate heart rate for regular

rhythms by dividing 1500 by the number of small boxes between R waves (1500/20 = 75).

This measurement reflects the standard paper speed of 25 mm/s, where 1500 small boxes

equal one minute. A common error is using this method for irregular rhythms, where the 6-

second strip method is more appropriate.


5. When placing electrodes on a patient with a left-side mastectomy, the technician should:

A. Place electrodes as close to the standard positions as possible without touching scar

tissue


B. Place the electrodes on the right side of the chest instead


C. Omit the V1 through V6 leads


D. Place electrodes on the back of the patient


Correct Answer: A

Document information

Uploaded on
August 13, 2026
Number of pages
29
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$19.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ScholarsAscend
3.8
(74)
Sold
435
Followers
39
Items
29278
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions