TANK SETTER QUESTIONS AND
ANSWERS WITH COMPLETE
SOLUTIONS 100% CORRECT RATED
A+ ||UPDATED 2026/2027
Effective system load is used to determine the amount of propane required to
operate appliances at a reduced demand and assumes the customers appliances -
ANSWER ✔✔ Operate at full demand only during typical operating cycles ,
for example during a clothes drying cycle or when cooking or they do not
operate simultaneously.
Frost penetration depth in the soil is important to consider when selecting above
ground tanks -ANSWER ✔✔ False
The two deciding factors for sizing underground tanks are the effective demand of
all existing and anticipated future gas appliances and_____ -ANSWER ✔✔ The
maximum anticipated soil frost penetration depth
Above ground tanks with less than ___ gallons water capacity may be placed next
to a building and must be at least ____ ft horizontally from any building opening
that is below the level of discharge -ANSWER ✔✔ 125/3
The primary factors affecting the rate or extent of corrosion for propane storage
containers and vapor distribution piping are -ANSWER ✔✔ Type of metal and
enviroment in which metal is exposed

Two commonly used cathodic protection methods are -ANSWER ✔✔Sacrificial
anodes and electrically insulating fittings

Regulator selection is based on -ANSWER ✔✔downstream gas demand and flow
rate

To prevent regulator freeze - up due to vent blockage caused by ice formation or
condensation , the regulator should be mounted so that the to allow drainage of
moisture that forms above the diaphragm -ANSWER ✔✔vent points downward

For a residential vapor distribution system involving a first- and second - stage
regulator , the highest Btu / hr output capacity for a single first - stage regulator is
not sufficient to meet total gas demand of the system . What is the best solution ? -
ANSWER ✔✔Install two first - stage regulators in a parallel installation

, When sizing vapor meters for 1/2 lb systems , select the meter according to its
capacity at 2 " w.c. pressure drop . -ANSWER ✔✔False

A circular meter index commonly has four dials that record the volume of gas used
. When reading the dials of a circular index , start with the dial -ANSWER
✔✔furthest to the right and proceed left

All of the following are examples of physical defects that would disallow a
container to be refilled EXCEPT : -ANSWER ✔✔Discoloration along the
container wall

ASME tanks used for LP - gas storage that have a water capacity of 125 gallons or
greater cannot be transported over a public roadway when filled to more than ___
of their water capacity -ANSWER ✔✔5 %

The steps to performing a leak test are as follows : Step 1 : Select a leak checking
device ; Step 2 : Choose an appropriate place in the plant to perform the inspection
: Step 3 ____ : Step 4 Use a leak detector to test for leaks -ANSWER
✔✔Pressurize the container

If you are transporting cylinders or tanks containing propane , you must carry
_____ -ANSWER ✔✔Shipping papers , a hazmat certificate of registration , and
emergency response information

Which of the following procedures for loading and securing propane cylinders on a
vehicle is NOT correct -ANSWER ✔✔Use the lift gate to load cylinders on the
service vehicle so most of the weight is on the front axle with side - to - side
distribution

Not all materials and supplies needed for installation at the customer site are
considered cargo ; only non - perishable materials must be secured under DOT
regulations -ANSWER ✔✔Flase

Which of the following must be performed before excavating underground tanks
and piping ? -ANSWER ✔✔Confirm the locations of underground utilities
Confirm the locations of customer - owned underground systems Ensure that the
buried tank or piping will not interfere with pre - installed utilities or systems

Document information

Uploaded on
August 9, 2026
Number of pages
6
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$19.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TESTSMASTER
3.8
(23)
Sold
107
Followers
2
Items
12144
Last sold
3 weeks ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions