Core Domains
1. Building Systems Operations (HVAC, Electrical, Plumbing)
2. Preventive and Corrective Maintenance Procedures
3. Health and Safety Regulations (OSHA, FDNY, DOB)
4. Energy Management and Sustainability Practices
5. Tools, Equipment, and Materials Identification
6. Blueprint Reading and Technical Drawings
7. Supervisory Skills and Personnel Management
8. NYC Building Codes and Regulatory Compliance
9. Emergency Response and Crisis Management
10. Record Keeping, Reporting, and Inventory Control

Introduction

This comprehensive practice examination is designed to rigorously prepare
candidates for the NYC Custodian Engineer certification. It assesses a broad
spectrum of foundational theories, applied professional knowledge, and critical
decision-making skills necessary for the effective and safe operation of complex
building systems. The test is structured in a multiple-choice and scenario-based
format, reflecting the real-world challenges encountered in managing modern
facilities. Each question emphasizes practical application, requiring candidates
to analyze situations and choose the most appropriate course of action based
on established regulations, ethical standards, and industry best practices,
ensuring they are fully prepared for the responsibilities of the role.




SECTION ONE: QUESTIONS 1-100

Question 1
In a large office building, the primary air handling unit (AHU) is experiencing
a significant drop in airflow. After verifying that the supply and return fans
are operational, what is the most likely and first component to inspect for a
blockage?

,A. The variable frequency drive (VFD)
B. The chilled water coil
C. The air filters
D. The supply duct diffusers

🟢C
🔴 Explanation: Air filters are the most common point of blockage in an
AHU. They are designed to capture particulates and will become clogged
over time, restricting airflow. While other components can cause issues,
inspecting the filters is the most logical and cost-effective first step in
troubleshooting airflow reduction.

Question 2
A custodial engineer is responsible for a building with a steam-to-hot water
heat exchanger. The building is experiencing low hot water temperatures.
The steam pressure is normal. What is the most probable cause?
A. A faulty low-water cut-off switch on the boiler.
B. The condensate return pump has failed.
C. The three-way mixing valve is stuck in the recirculation position.
D. The chemical feed pump for the hot water loop is malfunctioning.

🟢C
🔴 Explanation: If steam pressure is normal, the issue lies within the heat
exchanger system. A three-way mixing valve controls the temperature of the
water leaving the heat exchanger by mixing hot supply water with cooler
return water. If stuck in the recirculation position, it will continuously cycle
cooler water back into the system, preventing the temperature from reaching
the setpoint.

Question 3
What is the primary purpose of an Emergency Action Plan (EAP) as required
by building regulations?
A. To protect the building's physical assets from damage.
B. To ensure a safe and orderly evacuation of building occupants.
C. To satisfy annual fire department inspection requirements.
D. To document all safety training conducted for staff.

🟢B

,🔴 Explanation: The core purpose of an Emergency Action Plan is to provide
a framework for the safe and efficient evacuation of all building occupants
during an emergency. While it may include asset protection, its primary focus
is life safety. It must be clear, practiced, and readily accessible.

Question 4
Which of the following chemicals is most commonly used to control algae
and bacteria growth in a building's cooling tower sump?
A. Sodium phosphate
B. Sodium hypochlorite
C. Caustic soda
D. Hydrazine

🟢B
🔴 Explanation: Sodium hypochlorite (liquid bleach) is a common biocide
used in cooling towers to control microbiological growth like algae and
bacteria. This prevents biofouling, which can reduce heat transfer efficiency
and promote the growth of harmful bacteria like Legionella.

Question 5
A reciprocating chiller is short-cycling. Which of the following is the most
likely cause?
A. Low refrigerant charge
B. A faulty high-pressure cut-out switch
C. A clogged condenser tube bundle
D. A malfunctioning thermostat or control sensor

🟢D
🔴 Explanation: Short-cycling occurs when the chiller turns on and off
rapidly. This is frequently caused by a faulty control sensor or thermostat
sending an incorrect or intermittent signal to the control system, satisfying
the temperature setpoint too quickly or falsely. While other options can lead
to short-cycling or related issues, a faulty control sensor is the most direct
cause.

Question 6
During an annual inspection, what is the standard acceptable range for the
pH level of boiler water?

, A. 10.5 to 11.5
B. 7.0 to 8.5
C. 4.0 to 6.0
D. 12.0 to 14.0

🟢A
🔴 Explanation: Boiler water is maintained in an alkaline state, typically with a
pH between 10.5 and 11.5, to minimize the risk of corrosion and the
formation of scale. This pH range helps protect the metal surfaces of the
boiler and its associated piping.

Question 7
A custodial engineer notices a small, slow drip from a pipe fitting. This is
classified as what type of maintenance?
A. Emergency maintenance
B. Preventive maintenance
C. Corrective maintenance
D. Routine maintenance

🟢C
🔴 Explanation: Corrective maintenance is performed to restore an asset to
its proper operating condition after a deficiency or failure has been noticed.
A slow drip is a non-emergency failure that requires correction. It is not a
scheduled preventive task, and it does not pose an immediate hazard, so it is
not an emergency.

Question 8
What is the specific purpose of the "low water cut-off" (LWCO) on a steam
boiler?
A. To prevent the boiler from running when there is insufficient water.
B. To shut off the burner if the water pressure gets too high.
C. To activate the automatic water feed valve.
D. To maintain the correct water level in the boiler's sight glass.

🟢A
🔴 Explanation: The low-water cut-off is a crucial safety device. Its primary
function is to shut down the burner if the boiler's water level drops below a

Document information

Uploaded on
August 5, 2026
Number of pages
41
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$22.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
44
Last sold
-


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions