EXAM OVERVIEW

Component Details


Certification Type Type III - Low-Pressure Appliances


Primary
Centrifugal chillers using refrigerants like CFC-11, HCFC-123
Equipment


Recovery procedures, leak detection, purge units, safety regulations, evacuatio
Key Topics
levels




SECTION 1: TYPE III FUNDAMENTALS & EQUIPMENT IDENTIFICATION



Question 1
What type of equipment does a Type III certified technician primarily work on?

A) Small appliances with less than 5 pounds of refrigerant
B) High-pressure systems using HCFC-22
C) Low-pressure appliances such as chillers using CFC-11 or HCFC-123
D) Motor vehicle air conditioning systems

Correct Answer: C

Rationale: A Type III technician primarily works on equipment using a low-pressure
refrigerant such as HCFC-123 or CFC-11. These units are primarily chillers. Type I covers
small appliances, and Type II covers high-pressure systems.

,Question 2
Which refrigerants are classified as low-pressure refrigerants for Type III certification?

A) R-12, R-22, R-502
B) R-11, R-113, R-123
C) R-134a, R-410A, R-404A
D) R-744, R-717

Correct Answer: B

Rationale: Low-pressure refrigerants for Type III certification include R-11, R-113, and R-
123. These refrigerants have a boiling point above 10°C at atmospheric pressure. R-12,
R-22, and R-502 are high-pressure refrigerants for Type II.



Question 3
What is the boiling point characteristic of a low-pressure refrigerant?

A) Below -50°C at atmospheric pressure
B) Between -50°C and 10°C at atmospheric pressure
C) Above 10°C at atmospheric pressure
D) Below -100°C at atmospheric pressure

Correct Answer: C

Rationale: Low-pressure refrigerants have a boiling point above 10°C at atmospheric
pressure. High-pressure refrigerants have a boiling point between -50°C and 10°C at
atmospheric pressure.



Question 4
Why do chillers using refrigerants such as CFC-11 and HCFC-123 require a purge unit?

A) To remove oil from the system
B) To remove non-condensables from the system
C) To add refrigerant to the system
D) To increase system pressure

,Correct Answer: B

Rationale: Because chillers using refrigerants such as CFC-11 and HCFC-123 operate
below atmospheric pressure, they require a purge unit. The primary purpose of a purge
unit is to remove non-condensables (air and other gases) from the system.



Question 5
What is the primary purpose of a purge unit on a low-pressure chiller?

A) To remove refrigerant from the system
B) To remove non-condensables from the system
C) To add refrigerant to the system
D) To increase system pressure

Correct Answer: B

Rationale: The primary purpose of a purge unit is to remove non-condensables from
the system. Non-condensables reduce system efficiency and can cause corrosion. A
purge unit removes air and other gases while returning refrigerant to the system.



Question 6
Because a low-pressure system operates below atmospheric pressure (in a vacuum),
leaks in gaskets or fittings will cause:

A) Refrigerant to escape to the atmosphere
B) Air and moisture to enter the system
C) The system pressure to increase
D) The system to become over-pressurized

Correct Answer: B

Rationale: Because a low-pressure system operates below atmospheric pressure (in a
vacuum), leaks in the gaskets or fittings will cause air and moisture to enter the system.
This is opposite to high-pressure systems where refrigerant escapes.

, Question 7
All refrigeration systems must be protected by which device?

A) Purge unit
B) Pressure relief valve
C) Filter drier
D) Sight glass

Correct Answer: B

Rationale: All refrigeration systems must be protected by a pressure relief valve(s),
which must not be installed in series. This safety device prevents catastrophic over-
pressurization of the system.



Question 8
To protect the system from over-pressurization, low-pressure chillers typically use a
rupture disc mounted on the:

A) Compressor housing
B) Condenser shell
C) Evaporator housing
D) Liquid line

Correct Answer: C

Rationale: To protect the system from over-pressurization, low-pressure chillers
typically use a rupture disc mounted on the evaporator housing. The typical design
burst pressure for a rupture disc is 15 psig.



Question 9
What is the typical design burst pressure for a rupture disc on a low-pressure chiller?

A) 5 psig
B) 10 psig
C) 15 psig
D) 25 psig

Document information

Uploaded on
August 4, 2026
Number of pages
78
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$19.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AcademicACHIEVER
3.3
(82)
Sold
464
Followers
20
Items
12285
Last sold
7 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions