Question 1
Under the California Building Code, a skilled nursing facility (SNF) is classified as which
occupancy group?

A) Group I-1
B) Group I-2
C) Group R-3
D) Group B

Answer: B
Rationale: Skilled nursing facilities, where patients are incapable of self-preservation and
receive medical care on a 24-hour basis, are classified as Group I-2 (Institutional). Group I-1 is
for residential board and care facilities where occupants are capable of self-preservation.
Group R-3 is for one- and two-family dwellings, and Group B is for business occupancies.



Question 2
In a new skilled nursing facility corridor where residents may be transported in beds or
gurneys, the minimum clear width required by the CBC is:

A) 44 inches
B) 60 inches
C) 72 inches
D) 96 inches

Answer: B
Rationale: For new I-2 occupancies, the minimum clear corridor width in patient care areas
where beds or gurneys are used is 60 inches. This allows safe transport and egress. The 44-
inch width is permitted only in existing corridors or areas where no bed transport occurs. 72
inches and 96 inches exceed the minimum but are not the required minimum.

,Question 3
An inspector discovers that a resident’s sleeping room door in a skilled nursing facility swings
into the room. This is permitted if the room has an occupant load of:

A) 5 or less
B) 10 or less
C) 20 or less
D) Any occupant load

Answer: A
Rationale: NFPA 101 and the CBC permit a door to swing into a room if the occupant load is 5
or fewer and the door does not obstruct the corridor or reduce required egress width. Most
resident sleeping rooms meet this criterion. If the room served more than 5, the door would
have to swing in the direction of egress.



Question 4
A Class C Hospital Inspector is primarily responsible for inspecting:

A) Acute care hospital operating rooms
B) Skilled nursing facilities, intermediate care facilities, and residential care facilities for the
elderly
C) Public school buildings
D) High-rise office buildings

Answer: B
Rationale: Class C certification is specifically for inspectors who perform plan review and field
inspections of long-term care facilities, including SNFs, ICFs, and RCFEs. Class A inspectors
handle acute care hospitals. Schools and office buildings fall under other inspection
categories.



Question 5
What is the minimum fire-resistance rating of a corridor wall in a new fully sprinklered skilled
nursing facility?

A) 30 minutes
B) 1 hour

,C) 2 hours
D) No rating required

Answer: A
Rationale: In new health care occupancies that are fully protected by an approved automatic
sprinkler system, corridor walls may have a fire-resistance rating of 30 minutes. Without
sprinklers, a 1-hour rating is required. This reduction is allowed because the sprinklers control
fire growth.



Question 6
An inspector finds that a smoke barrier in a skilled nursing facility does not extend from the
floor to the underside of the floor or roof deck above. This is a deficiency because smoke
barriers must:

A) Be purely decorative
B) Form a continuous, airtight membrane to limit smoke migration
C) Only be installed if the facility has more than two stories
D) Be made of glass blocks

Answer: B
Rationale: Smoke barriers must be continuous from floor to deck to effectively
compartmentalize smoke. Gaps allow smoke to bypass the barrier, compromising the defend-
in-place strategy. The barrier is required regardless of building height. Glass blocks are not an
acceptable smoke barrier material without a rating.



Question 7
According to the CBC, a skilled nursing facility must have a minimum of how many exits from
each resident-occupied floor?

A) One
B) Two
C) Three
D) Four

Answer: B
Rationale: At least two independent exits are required from each story of a health care
occupancy, providing redundancy if one is blocked by fire or smoke. Additional exits may be
needed based on occupant load and travel distance, but two is the absolute minimum. One
exit is only allowed in very specific small conditions.

, Question 8
A resident room in a newly constructed SNF must provide a minimum of how many square
feet of floor area per bed (excluding toilet rooms, closets, and wardrobes)?

A) 60 sq ft
B) 80 sq ft
C) 100 sq ft
D) 120 sq ft

Answer: C
Rationale: California Title 22 regulations, which complement the building code, typically
require at least 100 square feet of usable floor area per bed in new skilled nursing facilities.
This ensures adequate space for care, equipment, and privacy. Older facilities may have lesser
requirements under existing standards.



Question 9
When inspecting a nursing home kitchen, the inspector notes that the range hood
suppression system is not interlocked with the building fire alarm. This is a violation because:

A) The hood system is only for smoke removal
B) The kitchen suppression system must activate the facility’s fire alarm system automatically
upon discharge
C) It only needs to be interlocked if the kitchen is open to the corridor
D) It is never required

Answer: B
Rationale: NFPA 96 requires that the activation of a kitchen hood suppression system
automatically trigger the building fire alarm. This alerts occupants and summons emergency
response. The interlock is not dependent on kitchen location. It’s a mandatory life safety
feature.



Question 10
Which of the following is the correct maximum travel distance from a resident room door to
an exit in a new sprinklered skilled nursing facility?

A) 100 feet
B) 150 feet

Document information

Uploaded on
July 31, 2026
Number of pages
40
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$21.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
1
Followers
0
Items
235
Last sold
3 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions