Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 41 pages
Exam (elaborations)

NYC MASTER ELECTRICIAN EXAM WITH ACCURATE QUESTIONS AND ANSWERS (VERIFIED ANSWERS) | LATEST (2026/2027) UPDATED VERSION | 100% GUARANTEED PASS {JUST RELEASED}

Document preview thumbnail
Preview 4 out of 41 pages

NYC MASTER ELECTRICIAN EXAM WITH ACCURATE QUESTIONS AND ANSWERS (VERIFIED ANSWERS) | LATEST (2026/2027) UPDATED VERSION | 100% GUARANTEED PASS {JUST RELEASED}

Content preview

NYC MASTER ELECTRICIAN EXAM
WITH ACCURATE QUESTIONS AND
ANSWERS (VERIFIED ANSWERS) |
LATEST (2026/2027) UPDATED
VERSION | 100% GUARANTEED PASS
{JUST RELEASED}



1. Type ____ is multiconductor cable identified for use as underground service
entrance cable. - ANSWER ✓ Type USE cable



2. Knife switch rated for more than 1200 Amps at 250Volts or less - ANSWER ✓
Can be used only as isolating switch, shall not be opened under load



3. Track lighting with outlets in a bathroom is not allowed because ? - ANSWER
✓ Track lighting has receptacle



4. Where internal combustion engines are used as the prime motor, an on site
fuel supply shall be provided with an on premise fuel supply sufficient for not
less than ____ hours full demand operation of the system - ANSWER ✓ 6
hours

,5. Fixed in place X-ray equipment properly supplied by a branch circuit rated at
not over ____ amperes shall be permitted to be supplied through a suitable
attachment plug cap and hard service cable cord. - ANSWER ✓ 30 Amps



6. Where skin effect exist the ferromagnetic envelope shall be bonded at ____. -
ANSWER ✓ Both ends



7. GFCI protection at a carnival is not required for equipment at circuit if the
receptacle is of the ____type. - ANSWER ✓ Locking



8. The maximum voltage drop from service point to the last over-current device
in a dwelling unit? - ANSWER ✓ 4%



9. Which of the following statements best describe the grounding requirement
for central vacuum outlet - ANSWER ✓ Accessible non current carrying metal
parts are required to be connected to an equipment grounding conductor.



10. In healthcare facilities, patient bed receptacles located in general care areas
shall be supplied by at least two branch circuits, which ____permitted to
originate from two separate transfer switches on the emergency system -
ANSWER ✓ Are permitted

,11. Patient care areas of healthcare facilities ____ areas such as business offices,
corridors, lounges ,day rooms, or similar areas - ANSWER ✓ Do not include



12. The patient care area is any portion of the healthcare facility where patients
are intended to be ____or ____. - ANSWER ✓ Examined or treated



13. Each general care area patient bed location in a healthcare facility must be
provided with four ____ or ____ duplex receptacles - ANSWER ✓ Single or
two



14. A hospital is a building or portion thereof used for medical,
psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more
patients - ANSWER ✓ Four



15. Where installed to reduce electrical noise for electronic equipment, electrical
continuity of the metal raceways shall not be required and metal raceway can
terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment -
ANSWER ✓ Listed fitting



16. Feeder and branch circuit conductors within ____ inches of a Ballast shall
have an insulation temperature rating not lower than 90°C (194°F) unless
supplying a luminaiere marked as suitable for a different insulation
temperature - ANSWER ✓ 3 inches

, 17. Manufactured wiring systems constructed with type MC cable shall be
supported and secured at intervals not exceeding ____ ft. - ANSWER ✓ 6 ft



18. Where a main bonding jumper or a system bonding jumper is a screw only the
screw shall be identified with a ____ that shall be visible with the screw
installed - ANSWER ✓ Green finish



19. Plug fuses a 15 amperes and lower rating shall be identified by a ____
configuration of the window, cap, or other prominent part to distinguish them
from fuses of higher ampere rating - ANSWER ✓ Hexagon



20. The load for household electric clothes dryer's in a dwelling unit(s) shall be
either ____ watts (volt-amperes) or the nameplate rating, which ever is
larger, for each dryer served ? - ANSWER ✓ 5000 watts



21. Service conductors installed as unjacketed multiconductor cable shall have a
minimum clearance of ____ windows that are designed to be opened, doors,
porches, stairs fire escape or similar locations. - ANSWER ✓ 3 ft (36 inches)



22. Cartridge fuses of the renewable type shall be permitted to be used only for
replacement in existing installation is where there is no evidence of over-
fusing or tampering. - ANSWER ✓ Class H

Document information

Uploaded on
July 30, 2026
Number of pages
41
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
2
Followers
0
Items
379
Last sold
1 month ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions