NATE Heat Pump Exam Questions and Correct Answers Rated A+ R-22 vapor line diameters and lengths are typically specified for a... - ANSWER -Vapor pressure drop that does not exceed a 6-7psi or 6 degrees F The primary purpose of using flux when soldering copper or brass parts is... - ANSWER To prevent oxidation The water that results from a defrost cycle of an air to air heat pump(runoff) must... - ANSWER Drain off and away fro the outdoor coil to prevent excessive ice build up on the bottom of the coil and reduce capacity The component used to reduce sound transmission and prevent water leaks of a packaged heat pump installed on a roof is... - ANSWER -Curb Gasket On some installations, a heat pump indoor coil can be installed on an existing, operable, fossil fuel furnace. When this type of installation is done, you need to add a control so that... - ANSWER -The furnace and heat pump do not operate at the same time in normal heating When under a deep vacuum, a hermetic refrigeration compressor's motor windings could be... - ANSWER -Damaged if energized 2 | Page In order for an evacuation to be considered complete... - ANSWER -A heat pump refrigeration circuit should be evacuated to a vacuum pressure of 500 microns or below A system is supplied from the factory with charge for a 15 FOOT LINESET. The data plate shows the required system charge to be 5 POUNDS 10 OUNCES. The lineset uses 3/8 inch liquid line and is 25 FEET LONG. The manufacturers instruction sheet specifies 0.6 ounces of refrigerant to be added for each added foot of refrigerant line length so... - ANSWER -The total refrigerant charge for the system would be 6 pounds Drive slips are typically installed on the... - ANSWER -Shorter sides of rectangular duct To properly set a heat anticipator, it is necessary to... - ANSWER -Check the heating control circuit amperage draw. A heat pump operating in normal ice free conditions maintains a certain temperature difference between the outdoor coil temperature and the surrounding outdoor ambient... - ANSWER -This temperature difference is referred to as coil TD The smallest refrigerant leak that an electronic leak detector should be capable of sensing is... - ANSWER -1/2 an ounce a year When checking the pressures in an operating system with a manifold gauge set... - ANSWER Refrigerant oil in a hose will have no effect on the gauge reading 3 | Page At sea level, a gauge pressure of 35 psig is equal to an... - ANSWER -Absolute pressure of 49,7 psia A technician measures the return air temperature of a 100,000 Btu output furnace to be 65F and the supply side air temperature is 135F... - ANSWER -The CFM should be 1323 A residential supply diffuser that is noisy because of a loose vane is best serviced by... - ANSWER Replacing the diffuser When performing preventive maintenance on a heat pump the technician should check the outdoor fan to be certain that the... - ANSWER Fan runs freely with no binding What is the effect of 170 volts supplied to a 208/230 volt compressor... - ANSWER -Would cause a current increase and the motor may trip on overload On a service call for a cooling problem with a heat pump, your inspections find a liquid line that has condensation on it... - ANSWER -The most likely cause would be the liquid line is restricted A reason for cool air complaints when a heat pump is operating in the heating cycle... - ANSWER - Excessive supply air velocities

Content preview

1 | Page




NATE Heat Pump Exam 2026- 2027 Questions and
Correct Answers Rated A+

R-22 vapor line diameters and lengths are typically specified for a... - ANSWER
-Vapor pressure drop that does not exceed a 6-7psi or 6 degrees F


The primary purpose of using flux when soldering copper or brass parts is... -
ANSWER To prevent oxidation


The water that results from a defrost cycle of an air to air heat pump(runoff)
must... - ANSWER Drain off and away fro the outdoor coil to prevent excessive
ice build up on the bottom of the coil and reduce capacity


The component used to reduce sound transmission and prevent water leaks of a
packaged heat pump installed on a roof is... - ANSWER -Curb Gasket


On some installations, a heat pump indoor coil can be installed on an existing,
operable, fossil fuel furnace. When this type of installation is done, you need to
add a control so that... - ANSWER -The furnace and heat pump do not operate at
the same time in normal heating


When under a deep vacuum, a hermetic refrigeration compressor's motor windings
could be... - ANSWER -Damaged if energized

,2 | Page




In order for an evacuation to be considered complete... - ANSWER -A heat pump
refrigeration circuit should be evacuated to a vacuum pressure of 500 microns or
below


A system is supplied from the factory with charge for a 15 FOOT LINESET. The
data plate shows the required system charge to be 5 POUNDS 10 OUNCES. The
lineset uses 3/8 inch liquid line and is 25 FEET LONG. The manufacturers
instruction sheet specifies 0.6 ounces of refrigerant to be added for each added
foot of refrigerant line length so... - ANSWER -The total refrigerant charge for
the system would be 6 pounds


Drive slips are typically installed on the... - ANSWER -Shorter sides of
rectangular duct


To properly set a heat anticipator, it is necessary to... - ANSWER -Check the
heating control circuit amperage draw.


A heat pump operating in normal ice free conditions maintains a certain
temperature difference between the outdoor coil temperature and the surrounding
outdoor ambient... - ANSWER -This temperature difference is referred to as coil
TD


The smallest refrigerant leak that an electronic leak detector should be capable of
sensing is... - ANSWER -1/2 an ounce a year


When checking the pressures in an operating system with a manifold gauge set... -
ANSWER Refrigerant oil in a hose will have no effect on the gauge reading

,3 | Page




At sea level, a gauge pressure of 35 psig is equal to an... - ANSWER -Absolute
pressure of 49,7 psia


A technician measures the return air temperature of a 100,000 Btu output furnace
to be 65F and the supply side air temperature is 135F... - ANSWER -The CFM
should be 1323


A residential supply diffuser that is noisy because of a loose vane is best serviced
by... - ANSWER Replacing the diffuser


When performing preventive maintenance on a heat pump the technician should
check the outdoor fan to be certain that the... - ANSWER Fan runs freely with no
binding


What is the effect of 170 volts supplied to a 208/230 volt compressor... -
ANSWER -Would cause a current increase and the motor may trip on overload


On a service call for a cooling problem with a heat pump, your inspections find a
liquid line that has condensation on it... - ANSWER -The most likely cause would
be the liquid line is restricted


A reason for cool air complaints when a heat pump is operating in the heating
cycle... - ANSWER -
Excessive supply air velocities

, 4 | Page




The following measurements are recorded on an operating heat pump system. The
heat pump is operating with the compressor only with no auxiliary heat
Heat pump only supply air temp.- 92F
Heat pump only return air temp.-70F
Outdoor temp.-54F
Supply air temp./ AUX heat ON- 115F
Return air temp./ AUX heat ON- 70F
CFM- 1228 - ANSWER -The heating capacity of the unit in would be 29,177


A dirty or clogged air filter in an operating heat pump system can cause... -
ANSWER Inadequate heating


To minimize noise problems in residential systems, what is the
range(recommended to maximum) of design air velocity in the rectangular main
supply trunk... - ANSWER -700900fpm


Proper ductwork connections and sealing is critical to good system performance.
Conditions are... - ANSWER -Return side air leak of 15% in a ventilated attic, 2.5
ton system rated at 1000 cfm, attic air- 95F


A technician has the following conditions while checking a packaged heat pump in
cooling
Piston-type metering device on both the indoor and outdoor coils
Outdoor temp.-75F

Document information

Uploaded on
July 29, 2026
Number of pages
43
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamMaestro
3.6
(18)
Sold
149
Followers
5
Items
3668
Last sold
13 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions