What are the potential benefits of an accolade ii stem? - Correct answer may fit a
broad range of bone sizes and shapes in today's patient population, it is optimized fit,
and length may promote implant stability, may be suitable for multiple surgical
approaches including the direct anterior approach
Which of the following is the correct neck length grouping for insignia? - Correct
answer 0/1 (yellow) 2/3/4 (blue) 5/6 (green) 7/8/9 (black) 1/11 (red)
Soma was utilized to match the accolade ii femoral components to the sizes and
shapes of a broad range of patient bone morphology - Correct answer true
A morphometric wedge stem is an evolution of the tapered wedge stem design with
(blank) to more closely fit a broad range of bone sizes and shapes of current patient
population - Correct answer size specific medial curvature
,Accolade ii is based on what type of stem philosophy? - Correct answer tapered wedge
What type of stem is the insignia stem? - Correct answer collared, metaphyseal filling
stem
T/f: insignia features soma designed size specific collars that are proportionate to the
implant body size to help minimize the likelihood of psoas impingement caused by
implant overhand - Correct answer true
Accolade ii is only offered in a high offset option - Correct answer false
Which of the following is correct about the insignia stem? - Correct answer the
insignia stem features a low-profile shoulder, short stem length, and distal relief
designed to provide ease of lateralization and insertion in muscle-sparing approaches
Insignias optimized stem length not only accommodates muscle-sparing approaches
but demonstrated enabled stability compared to a clinically successful fit and fill stem
with benchtop testing
,What material is the accolade ii stem made from? - Correct answer ti-6ai-4v material
What is the taper of the accolade ii stem? - Correct answer v-40
What are the features of insignia's soma designed tri-stage broaches - Correct answer
cutting teeth in m/l, compaction teeth in the a/p, and 0.5mm oversized aggressive
distal cutting teeth
What are the reasons for having a tri-stage broach for the insignia stem? - Correct
answer to remove cancellous bone in the m/l to capitalize on the clinically successful
accolade ii m/l geometry, preserve cancellous bone in the a/p while enhancing initial
rotational stability, and encourage metaphyseal fit
Which of the following is correct about the neck angle for insignia? - Correct answer
insignia offers a 132-degree neck angle with a +5mm direct lateral high offset option
What makes the accolade ii design unique from the other tapered wedge systems? -
Correct answer features a size specific medial curvature
, The accolade ii stem is what design? - Correct answer morphometric wedge
Regarding the accolade ii stem, a higher neck angle means - Correct answer
increased leg length, but decreased offset
What is the press-fit ratio in m/l and a/p for the insignia stem? - Correct answer .5mm
press-fit in a/p and .25 press-fit in m/l to provide accurate and reproducible stem
seating height to the final broach
The taper of the (blank) must fit the taper of the (blank) for a compatible fit - Correct
answer head, stem
When was the first mako robotic assisted surgery performed? - Correct answer 2006
Which applications were available when stryker purchased mako in 2013? - Correct
answer pka, tha
Update) Questions & Answers {Grade A}
100% Correct (Verified Solutions)
What are the potential benefits of an accolade ii stem? - Correct answer may fit a
broad range of bone sizes and shapes in today's patient population, it is optimized fit,
and length may promote implant stability, may be suitable for multiple surgical
approaches including the direct anterior approach
Which of the following is the correct neck length grouping for insignia? - Correct
answer 0/1 (yellow) 2/3/4 (blue) 5/6 (green) 7/8/9 (black) 1/11 (red)
Soma was utilized to match the accolade ii femoral components to the sizes and
shapes of a broad range of patient bone morphology - Correct answer true
A morphometric wedge stem is an evolution of the tapered wedge stem design with
(blank) to more closely fit a broad range of bone sizes and shapes of current patient
population - Correct answer size specific medial curvature
,Accolade ii is based on what type of stem philosophy? - Correct answer tapered wedge
What type of stem is the insignia stem? - Correct answer collared, metaphyseal filling
stem
T/f: insignia features soma designed size specific collars that are proportionate to the
implant body size to help minimize the likelihood of psoas impingement caused by
implant overhand - Correct answer true
Accolade ii is only offered in a high offset option - Correct answer false
Which of the following is correct about the insignia stem? - Correct answer the
insignia stem features a low-profile shoulder, short stem length, and distal relief
designed to provide ease of lateralization and insertion in muscle-sparing approaches
Insignias optimized stem length not only accommodates muscle-sparing approaches
but demonstrated enabled stability compared to a clinically successful fit and fill stem
with benchtop testing
,What material is the accolade ii stem made from? - Correct answer ti-6ai-4v material
What is the taper of the accolade ii stem? - Correct answer v-40
What are the features of insignia's soma designed tri-stage broaches - Correct answer
cutting teeth in m/l, compaction teeth in the a/p, and 0.5mm oversized aggressive
distal cutting teeth
What are the reasons for having a tri-stage broach for the insignia stem? - Correct
answer to remove cancellous bone in the m/l to capitalize on the clinically successful
accolade ii m/l geometry, preserve cancellous bone in the a/p while enhancing initial
rotational stability, and encourage metaphyseal fit
Which of the following is correct about the neck angle for insignia? - Correct answer
insignia offers a 132-degree neck angle with a +5mm direct lateral high offset option
What makes the accolade ii design unique from the other tapered wedge systems? -
Correct answer features a size specific medial curvature
, The accolade ii stem is what design? - Correct answer morphometric wedge
Regarding the accolade ii stem, a higher neck angle means - Correct answer
increased leg length, but decreased offset
What is the press-fit ratio in m/l and a/p for the insignia stem? - Correct answer .5mm
press-fit in a/p and .25 press-fit in m/l to provide accurate and reproducible stem
seating height to the final broach
The taper of the (blank) must fit the taper of the (blank) for a compatible fit - Correct
answer head, stem
When was the first mako robotic assisted surgery performed? - Correct answer 2006
Which applications were available when stryker purchased mako in 2013? - Correct
answer pka, tha