Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 35 pages
Exam (elaborations)

Master Electrician Test Money Maker Packet Preparation Newest 2026/2027 Complete Questions And Correct Detailed Answers (Verified Answers) |Brand New Version!!

Document preview thumbnail
Preview 4 out of 35 pages

Master Electrician Test Money Maker Packet Preparation Newest 2026/2027 Complete Questions And Correct Detailed Answers (Verified Answers) |Brand New Version!! If you have (2) parallel 300 KCMIL conductors installed in separate runs of PVC, what size EGC is needed in each pipe? - ANSWER-#1 If you have (2) sets of 3-phase 250 KCMIL conductors in separate dividers of cable tray for a service, what size EGC is needed? - ANSWER-4/0 A singles phase 325 amp load is supplied by a 350 amp breaker. The conductors are 400 KCMIL with a #3 EGC. If the supply conductors are increased to 500 KCMIL, what would be the new size EGC? - ANSWER-#2 What is the min size copper-clad grounding electrode conductor needed for a 200amp single phase dwelling copper feeder - ANSWER-2 awg 2 | Page The min distance any edge of a stud must be from the edge of a hole for nm cable is? - ANSWER-1 1/4 in Direct burial cable shall be installed how many inches below streets and parking lots? - ANSWER-24 When direct burial exits the ground, it shall be enclosed in a raceway or enclosure extending to a level of ____ ft above grade? - ANSWER-8 At what rated voltage does direct burial cable have to be shielded? - ANSWER-2000 volts What is the max distance for within sight? - SOLUTION=50 ft An electrical device that consists of a frame, a lunger and uses an up and down motion to operate is called what? - SOLUTION=Solenoid What are the types of equipment grounding conductors? - SOLUTION=rigid metal conduit and electrical metal tubing A 3 | Page restaurant has a 15.5 foot pug strip for all their television systems which are likely to be used at the same time. What is the VA? - SOLUTION=2880 VA An apartment has 8 water heaters a 800 watts, what is the VA? - SOLUTION=4800 A commercial garage has 55ft of track lighting, what is the VA? - SOLUTION=4200 240 volt to ground, 200 amp panel in condition 3 needs a minimum front clearance of ___ft? - SOLUTION=4 What is the minimum clearance in front of a service panel? - SOLUTION=3ft The width of the 120/240 volt panel working area shall be a minimum of __ft, and the door shall be open able to at least 90deg - SOLUTION=2 1/2 Manhole covers shall weigh more than how many pounds? -

Content preview

1 | Page




Master Electrician Test Money Maker Packet Preparation
Newest 2026/2027 Complete Questions And Correct Detailed
Answers (Verified Answers) |Brand New Version!!


If you have (2) parallel 300 KCMIL conductors installed in
separate runs of PVC, what size EGC is needed in each pipe? -
ANSWER-#1 If you have (2) sets of 3-phase 250 KCMIL
conductors in separate
dividers of cable tray for a service, what size EGC is needed? -
ANSWER-4/0


A singles phase 325 amp load is supplied by a 350 amp
breaker. The conductors are 400 KCMIL with a #3 EGC. If the
supply conductors are
increased to 500 KCMIL, what would be the new size EGC? -
ANSWER-#2


What is the min size copper-clad grounding electrode conductor
needed for a 200amp single phase dwelling copper feeder -
ANSWER-2 awg

,2 | Page




The min distance any edge of a stud must be from the edge of a
hole for nm cable is? - ANSWER-1 1/4 in
Direct burial cable shall be installed how many inches below
streets and parking lots? - ANSWER-24


When direct burial exits the ground, it shall be enclosed in a
raceway or
enclosure extending to a level of ____ ft above grade? -
ANSWER-8


At what rated voltage does direct burial cable have to be
shielded? -
ANSWER-2000 volts
What is the max distance for within sight? - SOLUTION=50 ft


An electrical device that consists of a frame, a lunger and uses
an up and down motion to operate is called what? -
SOLUTION=Solenoid


What are the types of equipment grounding conductors? -
SOLUTION=rigid metal conduit and electrical metal tubing A

,3 | Page




restaurant has a 15.5 foot pug strip for all their television
systems which are likely to be used at the same time. What is
the VA? - SOLUTION=2880 VA


An apartment has 8 water heaters a 800 watts, what is the VA? -
SOLUTION=4800


A commercial garage has 55ft of track lighting, what is the VA?
- SOLUTION=4200


240 volt to ground, 200 amp panel in condition 3 needs a
minimum front clearance of ___ft? - SOLUTION=4


What is the minimum clearance in front of a service panel? -
SOLUTION=3ft


The width of the 120/240 volt panel working area shall be a
minimum of __ft, and the door shall be open able to at least
90deg - SOLUTION=2 1/2


Manhole covers shall weigh more than how many pounds? -

, 4 | Page




SOLUTION=100lbs
a 240-volt boat hoist receptacle has to be? - SOLUTION=GFCI
Protected


Non-dwelling unit receptacles installed in/on the __ shall be
GFCI protected and installed in a readily accessible location -
SOLUTION=roof tops and outdoors


Rooftop units being supplied by feeder panels shall have a
receptacle that is ___? - SOLUTION=GFCI


What is the minimum rating for a laundry circuit in a single
family dwelling? - SOLUTION=20 amps 1500 watts


Branch circuits in hotels and assisted living units have to be? -
SOLUTION=AFCi


A receptacle on an individual branch circuit can be rated for
what percent? - SOLUTION=100%


Branch circuits ___ or larger shall supply only non-lighting

Document information

Uploaded on
July 26, 2026
Number of pages
35
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamMaestro
3.6
(18)
Sold
149
Followers
5
Items
3614
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions