Question 1
What is the primary legal responsibility of a Class A Field Safety
Representative (FSR) under the Safety Standards Act of BC?
A) To perform all electrical installations on behalf of contractors
B) To submit declarations confirming regulated electrical work
complies with the Safety Standards Act and applicable regulations
C) To issue electrical permits to all contractors in their region
D) To conduct criminal background checks on electrical workers
Correct Answer: B – An FSR's primary responsibility is to submit
declarations confirming that regulated electrical work complies with the
Safety Standards Act and applicable regulations.
Question 2
,A Class A FSR certificate allows declarations for electrical work with
what limitations?
A) Maximum 600V voltage limitation
B) Maximum 500 ampere limitation
C) No voltage or ampere limitations
D) Maximum 1000V and 1000 ampere limitation
Correct Answer: C – Class A is the highest FSR designation and allows
submission of declarations for any type of regulated electrical work with
NO voltage or ampere limitations.
Question 3
What is the minimum work experience required for an electrician to
qualify for a Class A FSR certification?
A) 1 year (1,800 hours)
B) 2 years (3,600 hours)
C) 3 years (5,400 hours)
D) 4 years (7,200 hours)
Correct Answer: B – A minimum of two years (3,600 hours) of relevant
electrical work experience under the Canadian Electrical Code is required
after receiving a Certificate of Qualification.
,Question 4
According to the Electrical Safety Regulation, what must an FSR
verify before submitting a declaration for a high voltage installation?
A) The contractor's business license status
B) That the installation complies with CE Code and applicable
regulations
C) The personal financial status of the electrical contractor
D) That all workers have completed red seal training
Correct Answer: B – The Electrical Safety Regulation requires FSRs to
verify that installations comply with the Canadian Electrical Code and
applicable regulations before submitting declarations.
Question 5
For a service to a residential dwelling in British Columbia, what is
the minimum size grounding electrode conductor required when the
service entrance conductor is #3/0 AWG copper?
A) #4 AWG copper
B) #6 AWG copper
C) #8 AWG copper
D) #10 AWG copper
, Correct Answer: C – According to the BC Electrical Code, a #3/0 AWG
copper service requires a minimum of #8 AWG copper for the grounding
electrode conductor.
Question 6
What is the maximum allowable voltage drop from the service point
to a remote sub-panel used for critical equipment?
A) 1%
B) 3%
C) 5%
D) No limit specified
Correct Answer: C – The CEC generally recommends a maximum total
voltage drop of 5% for feeders and branch circuits combined.
Question 7
An inspector finds a 200 A service panel with an open knockout that
is not used. What is the appropriate action?
A) Leave it if wiring is static
B) Install a proper blank cover or knockout seal
C) Tape it closed temporarily
D) Report but no correction required