OHIO STATE FIRE ALARM EXAM 2026/2027 |
Actual Exam Questions & Answers | Fire
Alarm Systems Certification | Pass
Guaranteed - A+ Graded




Question 1: A two-wire Class B circuit has 10 smoke detectors on it. A Class B
circuit will typically have an end-of-line device on the last detector in the circuit.
The end-of-line device is usually a _____.

A) Capacitor
B) Resistor
C) Diode
D) Transformer

Correct Answer: B
Rationale: A Class B circuit uses an end-of-line resistor to supervise the circuit for
integrity. The resistor allows the panel to detect opens or shorts in the wiring .




Question 2: Smoke detectors installed in air duct systems are normally used to
control spreading smoke.

A) True
B) False

Correct Answer: A
Rationale: Duct smoke detectors are primarily installed to prevent the spread of smoke
through HVAC systems by initiating fan shutdown, damper closure, or other smoke
control functions .

,Question 3: A smoke detector installed in an air duct system is permitted to be
used as a substitute for open area protection.

A) True
B) False

Correct Answer: B
Rationale: Duct detectors cannot substitute for open area protection. Areas in ducts,
below floors, and above ceilings are considered separate areas requiring their own
detection .




Question 4: If control circuits are used to shut down elevator power, the control
circuits are not required to be monitored for the presence of operating voltage.

A) True
B) False

Correct Answer: B
Rationale: Control circuits used for elevator power shutdown must be monitored for
the presence of operating voltage to ensure supervisory integrity .




Question 5: According to the Ohio Fire Code, in a covered mall building exceeding
50,000 ft² in area, a(n) ______ shall be provided.

A) Emergency Voice/Alarm Communications System
B) Manual pull station system
C) Waterflow alarm system
D) Local only alarm system

Correct Answer: A
Rationale: Covered mall buildings exceeding 50,000 square feet require an Emergency
Voice/Alarm Communications System to ensure effective evacuation communication .

,Question 6: A detector that is capable of resetting itself when the heat in the area
drops below the detector's set point is called a:

A) Nonrestorable heat detector
B) Restorable heat detector
C) Rate-of-rise detector
D) Fusible link detector

Correct Answer: B
Rationale: A restorable heat detector automatically resets when the temperature drops
below its set point after activation .




Question 7: Any alarm that occurs that is not the result of a potentially hazardous
condition is known as:

A) False alarm
B) Unwanted alarm
C) Nuisance alarm
D) Supervisory alarm

Correct Answer: B
Rationale: An unwanted alarm is defined as any alarm that occurs that is not the result
of a potentially hazardous condition .




Question 8: Smoke detectors must be functionally tested:

A) Monthly
B) Quarterly
C) Annually
D) Every 5 years

, Correct Answer: C
Rationale: NFPA 72 requires smoke detectors to be functionally tested on an annual
basis .




Question 9: Smoke alarms or smoke detectors are required at what locations?

A) In each sleeping room only
B) Outside each sleeping room only
C) On each level only
D) In each sleeping room, outside each sleeping room, and on each level

Correct Answer: D
Rationale: Smoke alarms are required in every sleeping room, outside each sleeping
area, and on every level of the home including basements .




Question 10: A Class X circuit is a redundant pathway that only applies to
addressable fire alarm signaling device circuits.

A) True
B) False

Correct Answer: A
Rationale: Class X circuits provide a redundant pathway, allowing continued
communication even with a single open or short circuit, and applies specifically to
addressable systems .




Question 11: When installing a smoke detector for door release service and the
depth of the wall above the door is greater than 24 inches on one side only, we
must install _____ ceiling-mounted detector(s) on the higher side or ____ wall-
mounted detector(s) (one on each side of the doorway).

A) 1, 2
B) 2, 1

Document information

Uploaded on
July 23, 2026
Number of pages
35
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$43.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Dock2
4.7
(3)
Sold
20
Followers
11
Items
3637
Last sold
1 month ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions