Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 90 pages
Exam (elaborations)

ABRET-EEG Actual Exam Study Questions with 100% Correct Answers Already Graded A+ | Brand New Version

Document preview thumbnail
Preview 4 out of 90 pages

ABRET-EEG Actual Exam Study Questions with 100% Correct Answers Already Graded A+ | Brand New Version 1. which of the following extra electrodes might best demonstrate the EEG activity associated with focal motor twitching of the right corner of the mouth? - ANSWER C5 2. sphenoidal electrodes are used to record activity from the - ANSWER anterior temporal lobes 3. what additional electrodes could be placed to help decipher between artifact and cortical activity - ANSWER EOG electrodes 4. what type of monitoring would be useful in an EEG with a patient experiencing syncope? - ANSWER ECG 5. Laplacian montage - ANSWER source reference derivation 6. EEG amplifiers work on the principle(s) of - ANSWER differentiation and amplification 7. Doubling the inter-electrode distances will have what effect on the waveforms? - ANSWER increase amplitude 8. term used to describe the. way a signal is sampled at intervals and assigned a numeric value - ANSWER sampling rate 9. Digital EEG montages are reformatted by using - ANSWER system reference 10. Input impedance should be - ANSWER very high 11. Low sampling rate may cause fast frequencies to appear slower: - ANSWER aliasing 12. 2016 ACNS guidelines recommends a CMRR of at least: - ANSWER 90 dB 13. which of the following sites is most commonly used for the ground electrode in EEG - ANSWER Fpz 14. For low frequency filters (LFFs), the corresponding time constants for LFF cutoff frequency of 3 Hz would be - ANSWER 0.05 seconds 15. frequency response curve - ANSWER filters 16. Vertical resolution - ANSWER amplitude 17. common mode rejection - ANSWER differential amplifier 18. A 0.3 Hz wave would be attenuated by what percentage with a 0.3 Hz filter? - ANSWER 0.3 19. long time constant - ANSWER LFF of .1 hz 20. Signals common to both inputs of a differential amplifier with like frequency, amplitude and phase are: - ANSWER canceled 21. under sampling - ANSWER Aliasing 22. an abbreviated 10-20 placement, respiration, ECG and EOG monitors should be used when recording - ANSWER neonates 23. what additional monitoring should be done in a middle age patient who repeatedly alerts from sleep during the EEG? - ANSWER Respiration 24. brain abscess - ANSWER focal polymorphic delta activity 25. Cortical EEG recordings can be obscured in patients who are tense and anxious due to - ANSWER myogenic artifact 26. which combination of settings will help enhance a low voltage slow wave that is being masked by muscle activity? - ANSWER Sen 5; LF .3; HF 35 27. to enhance the background alpha and beta asymmetry in an EEG record showing moderately high voltage delta activity, the tech should use a - ANSWER shorter time constant and increased sensitivity 28. A waveform of 0.5 Hz can be best enhanced with a filter of - ANSWER LF 0.3 Hz 29. of the following, the BEST choice of reference to be used when recording in suspected temporal lobe epilepsy is - ANSWER CZ 30. Which montage would be best to localize occipital spikes by phase reversal? - ANSWER circumferential bipolar montage 31. When using the average reference, if a spike-and-wave focus appears at C3, the abnormality would be best enhanced by - ANSWER excluding C3 and surrounding electrodes from reference 32. which of the following montages would best display the amplitude of a left temporal spike - ANSWER left temporal to the contralateral ear 33. when attempting to minimize relentless muscle artifact on a recording, the tech should be aware that lowering the high filter could cause the artifact to resemble - ANSWER beta activity 34. Referential recording is most appropriate for measuring - ANSWER voltage 35. which of the following settings could be used to reduce the effects of sweat artifact in a patient with asymmetrical low-voltage fast activity? - ANSWER -S = 5 microvolts/mm -LF = 5 Hz -HF = 70 Hz 36. which of the following is the most appropriate instrumentation setting change that should be made in order to enhance cortical slowing? - ANSWER Change the LFF from 1 Hz to .1 Hz 37. Fourteen and six Hz positive spikes are best recorded with - ANSWER the contralateral ear reference

Content preview

ABRET-EEG Actual Exam Study Questions
with 100% Correct Answers Already
Graded A+ | Brand New Version

1. which of the following extra electrodes might best demonstrate the EEG
activity associated with focal motor twitching of the right corner of the
mouth? - ANSWER C5


2. sphenoidal electrodes are used to record activity from the - ANSWER
anterior temporal lobes


3. what additional electrodes could be placed to help decipher between artifact
and cortical activity - ANSWER EOG electrodes


4. what type of monitoring would be useful in an EEG with a patient
experiencing syncope? - ANSWER ECG


5. Laplacian montage - ANSWER source reference derivation


6. EEG amplifiers work on the principle(s) of - ANSWER differentiation and
amplification


7. Doubling the inter-electrode distances will have what effect on the
waveforms? - ANSWER increase amplitude


8. term used to describe the. way a signal is sampled at intervals and assigned a
numeric value - ANSWER sampling rate

,9. Digital EEG montages are reformatted by using - ANSWER system
reference


10.Input impedance should be - ANSWER very high
11.Low sampling rate may cause fast frequencies to appear slower: -
ANSWER aliasing


12.2016 ACNS guidelines recommends a CMRR of at least: - ANSWER 90
dB


13.which of the following sites is most commonly used for the ground electrode
in EEG - ANSWER Fpz


14.For low frequency filters (LFFs), the corresponding time constants for LFF
cutoff frequency of 3 Hz would be - ANSWER 0.05 seconds


15.frequency response curve - ANSWER filters


16.Vertical resolution - ANSWER amplitude


17.common mode rejection - ANSWER differential amplifier


18.A 0.3 Hz wave would be attenuated by what percentage with a 0.3 Hz filter?
- ANSWER 0.3


19.long time constant - ANSWER LFF of .1 hz

,20.Signals common to both inputs of a differential amplifier with like
frequency, amplitude and phase are: - ANSWER canceled


21.under sampling - ANSWER Aliasing


22.an abbreviated 10-20 placement, respiration, ECG and EOG monitors should
be used when recording - ANSWER neonates


23.what additional monitoring should be done in a middle age patient who
repeatedly alerts from sleep during the EEG? - ANSWER Respiration


24.brain abscess - ANSWER focal polymorphic delta activity


25.Cortical EEG recordings can be obscured in patients who are tense and
anxious due to - ANSWER myogenic artifact


26.which combination of settings will help enhance a low voltage slow wave
that is being masked by muscle activity? - ANSWER Sen 5; LF .3; HF 35


27.to enhance the background alpha and beta asymmetry in an EEG record
showing moderately high voltage delta activity, the tech should use a -
ANSWER shorter time constant and increased sensitivity


28.A waveform of 0.5 Hz can be best enhanced with a filter of - ANSWER LF
0.3 Hz


29.of the following, the BEST choice of reference to be used when recording in
suspected temporal lobe epilepsy is - ANSWER CZ

, 30.Which montage would be best to localize occipital spikes by phase reversal?
- ANSWER circumferential bipolar montage
31.When using the average reference, if a spike-and-wave focus appears at C3,
the abnormality would be best enhanced by - ANSWER excluding C3 and
surrounding electrodes from reference


32.which of the following montages would best display the amplitude of a left
temporal spike - ANSWER left temporal to the contralateral ear


33.when attempting to minimize relentless muscle artifact on a recording, the
tech should be aware that lowering the high filter could cause the artifact to
resemble - ANSWER beta activity


34.Referential recording is most appropriate for measuring - ANSWER voltage


35.which of the following settings could be used to reduce the effects of sweat
artifact in a patient with asymmetrical low-voltage fast activity? -
ANSWER -S = 5 microvolts/mm
-LF = 5 Hz
-HF = 70 Hz


36.which of the following is the most appropriate instrumentation setting
change that should be made in order to enhance cortical slowing? -
ANSWER Change the LFF from 1 Hz to .1 Hz


37.Fourteen and six Hz positive spikes are best recorded with - ANSWER the
contralateral ear reference

Document information

Uploaded on
July 23, 2026
Number of pages
90
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
DrSammuel
5.0
(1)
Sold
7
Followers
0
Items
917
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions