NYC DCAS ELECTRICIAN EXAM – 300 COMPREHENSIVE PRACTICE QUESTIONS (NEC 2017/2020 & NYC AMENDMENTS) COMPLETE WITH 100% VERIFIED ANSWERS 1. What is the minimum size copper equipment grounding conductor required for a 400A feeder protected by a 400A breaker? A) #4 AWG B) #2 AWG C) #1/0 AWG D) #3/0 AWG Correct Answer: D 2. In a dwelling unit, hallway receptacles must be located so that no point along the floor line is more than how many feet from a receptacle? A) 6 feet B) 10 feet C) 15 feet D) 20 feet Correct Answer: B 3. What is the maximum allowable fill for a conduit containing three conductors? A) 31% B) 40% C) 53% D) 60% Correct Answer: B 4. For a 120/208V, 3-phase, 4-wire system, the high leg (wild leg) must be identified with what color? A) White B) Green C) Orange D) Blue Correct Answer: C 5. When installing PVC conduit in a cold storage warehouse, which of the following is required? A) Expansion fittings B) Threaded hubs C) Bonding locknuts D) Factory elbows only Correct Answer: A 6. A 30 HP, 460V, 3-phase induction motor has a full-load current of 40A. The minimum rated disconnect switch must be at least: A) 40A B) 50A C) 60A D) 115A Correct Answer: D 7. What is the minimum clearance for service drop conductors above a residential flat roof that is not accessible to pedestrians? A) 8 feet B) 10 feet C) 12 feet D) 15 feet Correct Answer: A 8. The maximum number of 10 AWG THHN conductors allowed in 1-inch EMT is: A) 10 B) 13 C) 16 D) 20 Correct Answer: C 9. What is the minimum burial depth for rigid metal conduit (RMC) under a driveway in a residential application? A) 6 inches B) 12 inches C) 18 inches D) 24 inches Correct Answer: D 10. A continuous load of 24A on a 240V circuit requires a branch circuit overcurrent device rated at no less than: A) 24A B) 25A C) 30A D) 35A Correct Answer: C 11. Which of the following is permitted to be used as an equipment grounding conductor for a branch circuit? A) White insulated conductor re-identified with green tape at both ends B) Flexible metal conduit over 6 feet long C) The metal sheath of a service entrance cable D) A bare copper conductor run with the circuit conductors Correct Answer: D 12. In a commercial kitchen, a receptacle installed to serve a countertop must be GFCI protected and located not more than how many inches above the counter? A) 12 inches B) 18 inches C) 20 inches D) 24 inches Correct Answer: C 13. The minimum size conductor for a 15A branch circuit using copper is: A) #14 AWG B) #12 AWG C) #10 AWG D) #8 AWG Correct Answer: A 14. When using nonmetallic sheathed cable (NM) in an unfinished basement, it must be protected from physical damage if installed where? A) Within 6 feet of the floor B) Within 5 feet of the floor C) Within 7 feet of the floor D) Within 8 feet of the floor Correct Answer: A

Content preview

NYC DCAS ELECTRICIAN EXAM – 300 COMPREHENSIVE PRACTICE
QUESTIONS (NEC 2017/2020 & NYC AMENDMENTS) COMPLETE WITH
100% VERIFIED ANSWERS


1. What is the minimum size copper equipment grounding conductor
required for a 400A feeder protected by a 400A breaker?
A) #4 AWG
B) #2 AWG
C) #1/0 AWG
D) #3/0 AWG
Correct Answer: D
2. In a dwelling unit, hallway receptacles must be located so that no
point along the floor line is more than how many feet from a
receptacle?
A) 6 feet
B) 10 feet
C) 15 feet
D) 20 feet
Correct Answer: B
3. What is the maximum allowable fill for a conduit containing three
conductors?
A) 31%
B) 40%
C) 53%
D) 60%
Correct Answer: B

,4. For a 120/208V, 3-phase, 4-wire system, the high leg (wild leg) must
be identified with what color?
A) White
B) Green
C) Orange
D) Blue
Correct Answer: C
5. When installing PVC conduit in a cold storage warehouse, which of
the following is required?
A) Expansion fittings
B) Threaded hubs
C) Bonding locknuts
D) Factory elbows only
Correct Answer: A
6. A 30 HP, 460V, 3-phase induction motor has a full-load current of
40A. The minimum rated disconnect switch must be at least:
A) 40A
B) 50A
C) 60A
D) 115A
Correct Answer: D
7. What is the minimum clearance for service drop conductors above a
residential flat roof that is not accessible to pedestrians?
A) 8 feet
B) 10 feet
C) 12 feet

,D) 15 feet
Correct Answer: A
8. The maximum number of 10 AWG THHN conductors allowed in 1-
inch EMT is:
A) 10
B) 13
C) 16
D) 20
Correct Answer: C
9. What is the minimum burial depth for rigid metal conduit (RMC)
under a driveway in a residential application?
A) 6 inches
B) 12 inches
C) 18 inches
D) 24 inches
Correct Answer: D
10. A continuous load of 24A on a 240V circuit requires a branch circuit
overcurrent device rated at no less than:
A) 24A
B) 25A
C) 30A
D) 35A
Correct Answer: C
11. Which of the following is permitted to be used as an equipment
grounding conductor for a branch circuit?
A) White insulated conductor re-identified with green tape at both ends
B) Flexible metal conduit over 6 feet long

, C) The metal sheath of a service entrance cable
D) A bare copper conductor run with the circuit conductors
Correct Answer: D
12. In a commercial kitchen, a receptacle installed to serve a countertop
must be GFCI protected and located not more than how many inches
above the counter?
A) 12 inches
B) 18 inches
C) 20 inches
D) 24 inches
Correct Answer: C
13. The minimum size conductor for a 15A branch circuit using copper
is:
A) #14 AWG
B) #12 AWG
C) #10 AWG
D) #8 AWG
Correct Answer: A
14. When using nonmetallic sheathed cable (NM) in an unfinished
basement, it must be protected from physical damage if installed
where?
A) Within 6 feet of the floor
B) Within 5 feet of the floor
C) Within 7 feet of the floor
D) Within 8 feet of the floor
Correct Answer: A

Document information

Uploaded on
July 23, 2026
Number of pages
77
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
maingirose
5.0
(2)
Sold
14
Followers
0
Items
1321
Last sold
4 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions