NFPA 96 STUDY GUIDE 2026 EXAM QUESTIONS AND
ANSWERS RATED A+
✔✔6.1 ___________ for wet chemical fire extinguishing systems shall be drawn up by
or under the supervision of a trained person with the advice of the authority having
jurisdiction. - ✔✔"specifications"

✔✔6.2 Design and installation of systems shall be performed only by persons properly
trained and qualified to design and/ or install the specific system being provided. The
installer shall provide certification to the ______________ that the installation complies
with the terms of the listing and the manufacturer's instructions and/ or approved design.
- ✔✔"authority having jurisdiction"

✔✔7.3.2 A service technician who has the applicable manufacturer's design,
installation, and maintenance manual and service bulletins shall service the wet
chemical fire-extinguishing system at intervals of no more than ___________ as
outlined in 7.3.3 - ✔✔"6 months"

✔✔7.3.3 At least __________ and after any system activation, maintenance shall be
conducted in accordance with the manufacturer's design, installation, and maintenance
manual. - ✔✔"Semiannually"

✔✔7.3.4 Fixed temperature-sensing elements of the fusible metal alloy type shall be
replaced at least __________ from the date of installation or more frequently, if
necessary, and shall be destroyed when removed. - ✔✔"Semiannually"

✔✔3.3.15 A metal-joining method that produces a product without visible interruption or
variation in quality. - ✔✔Continuous Weld

✔✔3.3.31 Constructed and performing in such a manner as not to permit the passage
of any grease under normal cooking conditions. - ✔✔Greasetight

✔✔3.3.35 Constructed and performing in such a manner as not to permit the passage
of any liquid at any temperature. - ✔✔Liquidtight

✔✔3.3.43 Air deliberately brought into the structure, then specifically to the vicinity of
either a combustion process or a mechanically or thermally forced exhausting device, to
compensate for the vapor and/or gases being consumed or expelled. - ✔✔Replacement
Air

✔✔4.2.1 Where enclosures are not required, hoods, grease removal devices, exhaust
fans, and ducts shall have a clearance of at least ________ to combustible material. -
✔✔18in

, ✔✔4.4.3 Where the duct is listed for zero clearance to combustibles or is otherwise
protected with a material or product listed for the purpose of reducing clearance to zero,
the duct shall be permitted to _________ the contact limits of 4.4.1 without additional
corrosion protection. - ✔✔exceed

✔✔5.1.1 The hood or that portion of a primary collection means designed for collecting
cooking vapors and residues shall be constructed of and be supported steel not less
than ____________ in thickness, stainless steel not less than ___________ in
thickness, or other approved material of equivalent strength and fire and corrosion
resistant. - ✔✔18 MSG and 20 MSG

✔✔5.1.2 All seams, joints, and penetrations of the hood enclosure that direct and
capture grease-laden vapors and exhaust gases shall have a _____________________
to the hood's lower outermost perimeter. - ✔✔liquidtight continuous weld

✔✔5.1.3 Seams, Joints, and penetrations of the hood shall be permitted to be
_____________, provided that the weld is formed smooth or ground smooth, so as to
not trap grease, and is cleanable. - ✔✔Internally welded

✔✔5.1.4 Internal hood joints, seams, filter support frames, and appurtenances attached
inside the hood shall be ________ or ______________. - ✔✔sealed or otherwise made
greasetight

✔✔5.1.5 Penetrations shall be permitted to be sealed by devices that are listed for such
use and whose presence does not detract from the hood's or duct's ______________. -
✔✔structural integrity

✔✔5.1.6 Listed exhaust hoods with or without exhaust dampers shall be permitted to be
constructed of materials required by the ____________. - ✔✔listing

✔✔5.1.7 Listed exhaust hoods with or without exhaust dampers shall be permitted to be
assembled in accordance with the _____________. - ✔✔listing requirements

✔✔5.3.4.1 A fire-actuated damper shall be installed in the supply air plenum at each
point where a supply air duct inlet or supply air outlet penetrates the
_______________________. - ✔✔continuously welded shell of the assembly

✔✔5.3.4.2 The fire damper shall be listed for such use or be part of a listed exhaust
hood _________________________. - ✔✔with or without exhaust damper.

✔✔5.3.4.3 The actuation device shall have a maximum temperature rating of
_____________. - ✔✔286F. (141 C.)

Written for

Institution
A++
Course
A++

Document information

Uploaded on
July 21, 2026
Number of pages
9
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$18.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
cafe

Get to know the seller

Seller avatar
cafe Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
-
Member since
5 days
Number of followers
0
Documents
1112
Last sold
-
level 3

exam

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions