Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

S-98 FDNY STUDY GUIDE 2026 TIPS QUESTIONS AND ANSWERS RATED A

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
21-07-2026
Written in
2025/2026

S-98 FDNY STUDY GUIDE 2026 TIPS QUESTIONS AND ANSWERS RATED A

Institution
A++
Course
A++

Content preview

S-98 FDNY STUDY GUIDE 2026 TIPS QUESTIONS AND
ANSWERS RATED A+
✔✔_________________ does not ensure that each smoke detector is within its listed
ranges. - ✔✔A smoke entrance method

✔✔A notification appliance is located at the end of a 24V circuit. The device requires at
least 24 volts in order to operate. ______ gage size wires are needed for this device to
operate. (NFPA 20) - ✔✔14

✔✔The wire nuts used in NYC to splice fire alarm conductors must be rated at a
temperature of _______. - ✔✔150c

✔✔The requirements for grounding a fire alarm system are based on
____________________. - ✔✔NYC electrical code Article 250.

✔✔____________ of the national electrical code addresses the requirements for fire
alarm. - ✔✔Article 760

✔✔______ AWG is the minimum required wire for grounding a fire alarm system in
NYC. - ✔✔8

✔✔______ AWG is the stranded wire allowed to be used in NYC fire alarm installations.
- ✔✔8

✔✔Article _______ of the National Electrical Code addresses the requirements for fire-
stopping. - ✔✔300 (NFPA 70 article 300.21)

✔✔The standard fire alarm evacuation is a ________ pulse temporal pattern using any
appropriate sound. - ✔✔Three

✔✔Upon recite of a trouble signal/supervisory signal, the central station shall notify the
subscriber's representatives within ________. - ✔✔4 minutes

✔✔Based on the 1968 building code, a coded alarm signal shall consist of not less than
_____ of the number transmitted. Each number shall consist of ______. - ✔✔four
rounds; three impulses

✔✔By NYC fire code definition, an unnecessary alarm is considered to be an alarm
________________________. - ✔✔caused by a cigarette smoke from a lit cigarette in a
non-smoking area.

, ✔✔A certificate of of Fitness holder, after observing smoke detectors which appear to
be painted shall __________________________________. - ✔✔make a log and notify
the building owner that the smoke detectors need to be replaced.

✔✔The minimum distance between a smoke detector and an air supply should be
_________. - ✔✔3 Feet

✔✔A smoke detector maintenance log book must be readily accessible on premises for
a period of ___________ from the original entry. - ✔✔3 years

✔✔A central station log book should be kept for a minimum of ________ from the
original entry. - ✔✔6 years

✔✔Crossed zone circuits are utilized especially where detectors _________________. -
✔✔initiate a discharge of an extinguishing system

✔✔According to RCNY 907-01, it is unlawful to transmit two or more unnecessary
alarms in any period of ____________. - ✔✔three months

✔✔The correct heat detector to be used to address thermal lag is _________________.
- ✔✔Rate Compensation Detector

✔✔Smoke detectors with a reading of ______ outside of the manufactures
recommended shall be replaced. - ✔✔0.25

✔✔___________________ can be used in fire alarm systems. - ✔✔Sealed lead acid
batteries

✔✔___________________ shall be responsible for ensuring that the fire and life safety
systems are maintained in good working order at all times. - ✔✔The building owner

✔✔__________________ should not patrol more than _________________ of building
floor area. - ✔✔Fire Guards; 50,000 square feet

✔✔___________________ can be used in fire alarm systems. - ✔✔Sealed lead acid
batteries

✔✔Skyscraper is a Class - ✔✔A

✔✔Manual pull station needs to be _____ above ground - ✔✔4 feet

✔✔ Who is responsible for alarm system testing and maintenance? - ✔✔The property
owner

Written for

Institution
A++
Course
A++

Document information

Uploaded on
July 21, 2026
Number of pages
7
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$16.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
cafe

Get to know the seller

Seller avatar
cafe Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
-
Member since
5 days
Number of followers
0
Documents
1112
Last sold
-
level 3

exam

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions