ABYC Systems Certification Exam Review Verified Exam Questions
and Answers Latest update 2026/2027

Question:
175%

Answer:
At what what percentage of nominal working pressure shall the relief valve be set?

Question:
nominal working pressure, not to exceed 80 PSI

Answer:
For the pressure reducing valve and check valve installed after a shore water connection, what is the
maximum allowable pressure?

Question:
3 PSI or mnfg's maximum, which ever is greater.

Answer:
What is the maximum allowable pressure to which the storage tank and vent system be subjected?

Question:
True

Answer:
Storage tank inlet caps must be retained to prevent loss. T or F?

Question:
True

Answer:
Storage tanks must be equipped with a vent. T or F?

Question:
True

Answer:
Storage tank vent may be used for filling purposes. T or F?

,Question:
At least 1.5X the pressure exerted by the distance from the tank bottom to the deck fill plate or vent,
but not less than 3 PSI.

Answer:
What rate of static pressure must a storage tank withstand?

Question:
3 PSI

Answer:
What is the max pressure that a desalinator can impart to a storage tank?

Question:
True

Answer:
Each desalinator must be equipped with an automatic shutoff salinity detector. T or F?

Question:
"For Cold Water Use Only"

Answer:
What marking must be on pipe or tubes that are not capable of handling hot water?

Question:
125 PSI, 300 PSI

Answer:
What is the test pressure for water heater tank 15 gal or less? over 15 gal but under 120 gal?

Question:
175 PSI

Answer:
What is the max pressure relief valve setting for hot water tanks?

Question:
210 F

Answer:
What is the max temperature relief setting for hot water tanks?

,Question:
125 F

Answer:
What is the max allowable water output temperature for hot water system?

Question:
True

Answer:
All potable water system connections shall be positioned above the normal bilge water accumulation
level. T or F?

Question:
True

Answer:
Exposed metallic parts of a potable water system shall have provisions for electrical bonding. T or F?

Question:
Improper venting

Answer:
For what reason might a holding tank collapse during pump-out?

Question:
Type I

Answer:
What type of MSD (Marine Sanitation Device) discharges effluent with fecal coliform bacteria count
<= 1,000 (per 100 ml) and no suspended solids?

Question:
Type II

Answer:
What type of MSD (Marine Sanitation Device) discharges effluent with fecal coliform bacteria count
<= 200 (per 100 ml) and <= 150 mg suspended solids per liter?

Question:
Type III

Answer:
What type of MSD (Marine Sanitation Device) is designed to hold sewage or any waste derived from
sewage?

, Question:
Retention System

Answer:
What is the name given to the complete system including toilets, hoses, pipes, holding tanks and
fittings designed to receive, retain, vent and pump out sewage?

Question:
Treatment System

Answer:
What is the name of the system that includes all sanitation equipment and fittings designed to receive,
treat, vent and discharge sewage?

Question:
Siphon break

Answer:
What is another name for a vented loop that prevents back siphoning by breaking suction yet allowing
normal flow when pressurized?

Question:
True

Answer:
True or False: If a portable toilet is secured and fitted with a deck pump-out fitting and vent it qualifies
as a type III device.

Question:
Prevention of siphoning

Answer:
Why must careful consideration be given to the location and routing of inlet and discharge lines for
manual flush toilets when the "shut-off" merely bleeds air into the inlet line?

Question:
Whenever components are installed below the max heeled water line - to prevent back flow into the
vessel or unintentional siphoning of untreated effluent overboard.

Answer:
When and why must siphon breaks be installed in a sewage system?

Document information

Uploaded on
July 19, 2026
Number of pages
45
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.98

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
20
Followers
0
Items
10034
Last sold
3 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions