and Correct Answers
Question 1
The largest hand bender is what size?
Correct Answer
1-1/4 trade size
Question 2
What is the space defined as a case or housing dedicated to the telecommunications
function and related support facilities.
Correct Answer
TE
Question 3
Plywood SHOULD be installed on at LEAST _____________ walls in a TR
Correct Answer
2
Question 4
What type of system is used to extend cellular coverage into a building to provide
adequate coverage throughout the inside of the building?
Correct Answer
DAS
Page 1 of 60
,Question 5
The main difference between an entrance facility and this room is that this room is
generally considered to be floor-serving as opposed to building serving facilities.
Correct Answer
TR
Question 6
What color represents 1st level backbone cross-connect in a telecommunications
room?
Correct Answer
White
Question 7
What finished grade of plywood should be used in a telecommunications room?
Correct Answer
A/C
Question 8
Which class of administration of a SCS addresses infrastructure with multiple sight or
campuses?
Correct Answer
4
Question 9
The function of which type of cable is to provide interconnections between
equipment rooms and telecommunications rooms?
Correct Answer
Backbone cable
Page 2 of 60
,Question 10
What is the maximum allowable horizontal cable length?
Correct Answer
295'
Question 11
What color represents the horizontal cabling cross-connect in a telecommunications
room?
Correct Answer
Blue
Question 12
What are the common depths of equipment racks?
Correct Answer
4" and 6"
Question 13
The first cable to a work area should be at a minimum ____________
Correct Answer
Cat5e
Question 14
How many levels of back cabling are there?
Correct Answer
2
Question 15
How many transition points can you install in a horizontal cabling run?
Correct Answer
1
Page 3 of 60
, Question 16
What type of telecommunications space generally houses equipment that serves and
entire building, campus, or customer?
Correct Answer
ER
Question 17
You are installing horizontal structured cabling in an open office environment with
modular furniture. You are using category 6A cabling. You have to terminate 22
cabling runs in each modular furniture cluster of 11 units, and you are using MUTOAs.
How many MUTOAs are required for this application.
Correct Answer
1
Question 18
What is the color code for the Miscellaneous cross connect field?
Correct Answer
Yellow
Question 19
What type of conduit should not be used inside commercial buildings?
Correct Answer
PVC
Question 20
What is the point where the service provider network ends and the customer network
begins?
Correct Answer
Demarcation Point