DETAILED ANSWERS | PLUS RATIONALES | GUARANTEED PASS | LATEST EXAM UPDATE
Core Domains
• General Plumbing Regulations and Administrative Procedures
• Fixture Requirements and Water Heater Installation Standards
• Water Supply and Distribution Systems
• Sanitary Drainage and Venting Principles
• Indirect/Special Waste and Traps/Interceptors
• Storm Drainage Systems and Calculations
• Backflow Prevention and Cross-Connection Control
• Fuel Gas Piping and Appliance Venting
• Medical Gas and Vacuum Systems
• Safety, OSHA Standards, and Mathematics for Plumbers
Introduction
This assessment is designed to comprehensively evaluate the competency of individuals
seeking licensure within the state of Utah. The purpose of this exam is to ensure that
candidates possess the fundamental knowledge and technical proficiency required to protect
public health and safety through proper plumbing practices. The assessment covers a wide
array of topics, including code compliance, system design, and specialized installation
techniques. Utilizing a combination of multiple-choice questions and complex, scenario-
based applications, the exam emphasizes real-world decision-making and the practical
implementation of plumbing theory. Candidates must demonstrate a mastery of professional
standards and regulatory requirements to succeed.
SECTION ONE: QUESTIONS 1–100
1. What is the minimum required size for a building sewer that serves a residential
dwelling?
A. 2 inches B. 3 inches C. 4 inches D. 6 inches
4 inches
Explanation: Building codes generally require a minimum of 4 inches for the building
sewer to ensure adequate flow and prevent blockages for a standard residential load.
2. Which of the following is considered a "cross-connection" in a plumbing system?
,A. A connection between two different water heaters. B. A connection between a potable
water system and a non-potable source. C. A pipe that joins the hot and cold water lines at a
mixing valve. D. The installation of a cleanout on a drainage line.
A connection between a potable water system and a non-potable source.
Explanation: A cross-connection is any actual or potential link between a potable water
supply and any source of contamination or pollution.
3. When installing a water heater in a garage, the ignition source must be at least how
many inches above the floor?
A. 6 inches B. 12 inches C. 18 inches D. 24 inches
18 inches
Explanation: To prevent the ignition of flammable vapors that may accumulate at floor
level, ignition sources must be elevated to a minimum of 18 inches.
4. A plumber is calculating the slope of a 100-foot horizontal drainage pipe. If the
required slope is 1/4 inch per foot, what is the total drop?
A. 12.5 inches B. 25 inches C. 50 inches D. 100 inches
25 inches
Explanation: Multiplying 100 feet by 0.25 inches per foot results in a total vertical drop
of 25 inches.
5. What is the primary purpose of a P-trap in a plumbing system?
A. To regulate water pressure. B. To prevent sewer gases from entering the building. C. To
catch gold and jewelry dropped down the drain. D. To increase the velocity of waste flow.
To prevent sewer gases from entering the building.
Explanation: The water seal within the P-trap acts as a barrier that prevents foul-smelling
and potentially dangerous sewer gases from escaping into the living space.
6. Which type of venting relies on the drainage pipe itself to provide air circulation?
A. Individual vent B. Stack vent C. Wet vent D. Circuit vent
Wet vent
Explanation: A wet vent is a pipe that serves as both a waste pipe for one or more
fixtures and as a vent for others in the same horizontal branch.
7. What is the maximum distance allowed between a 1.5-inch fixture trap and its vent?
,A. 3 feet 6 inches B. 5 feet C. 6 feet D. 8 feet
6 feet
Explanation: Per standard code tables, a 1.5-inch trap is permitted a maximum
horizontal distance of 6 feet to the vent connection.
8. When testing a DWV (Drain, Waste, and Vent) system with water, the system must
hold a column of water at least how many feet high?
A. 5 feet B. 10 feet C. 15 feet D. 20 feet
10 feet
Explanation: A 10-foot head of water is the standard requirement for water-testing a
DWV system to ensure no leaks exist under pressure.
9. In a medical gas system, which color is universally used to identify Oxygen piping?
A. Yellow B. Blue C. Green D. White
Green
Explanation: According to NFPA 99 standards, green is the color coding used specifically
for Oxygen gas systems.
10. A backflow preventer that consists of two independently acting check valves with an
intermediate relief valve is known as a:
A. Double check valve assembly B. Pressure vacuum breaker C. Reduced pressure principle
backflow preventer D. Atmospheric vacuum breaker
Reduced pressure principle backflow preventer
Explanation: An RPZ (Reduced Pressure Zone) assembly utilizes two check valves and a
relief valve to provide the highest level of protection against both backpressure and
backsiphonage.
11. What is the required clearance in front of a 3-inch cleanout?
A. 12 inches B. 18 inches C. 24 inches D. 30 inches
18 inches
Explanation: An 18-inch clearance is required to allow sufficient room for plumbing tools
and rods to clear the line effectively.
12. Which material is prohibited for use as a water distribution pipe inside a building?
A. Copper Type M B. PEX C. Galvanized Steel D. CPVC
, Galvanized Steel
Explanation: While once common, many modern codes prohibit galvanized steel for new
water distribution due to internal corrosion and scaling issues over time.
13. A plumbing fixture that discharges into an indirect waste pipe is generally:
A. A water closet B. A kitchen sink with a disposal C. A commercial dishwasher or ice
machine D. A bathtub
A commercial dishwasher or ice machine
Explanation: Indirect waste is used for food-related or sterile equipment to prevent
potential backflow of sewage into the appliance via an air gap.
14. What is the minimum size of a water service pipe from the street to a typical single-
family home?
A. 1/2 inch B. 3/4 inch C. 1 inch D. 1.25 inches
3/4 inch
Explanation: Most residential codes mandate a minimum 3/4-inch diameter for the main
water service line to provide adequate volume and pressure.
15. What must be installed on a water heater to prevent excessive pressure or
temperature buildup?
A. A check valve B. A pressure reducing valve C. A T&P relief valve D. An expansion tank
A T&P relief valve
Explanation: The Temperature and Pressure (T&P) relief valve is a safety device designed
to open if the water temperature or pressure exceeds safe limits, preventing tank explosions.
16. How many Drainage Fixture Units (DFUs) are assigned to a standard residential water
closet with a 1.6 gpf rating?
A. 1 DFU B. 2 DFUs C. 3 DFUs D. 4 DFUs
3 DFUs
Explanation: Standard code tables assign 3 DFUs to a water closet when calculating the
load on a drainage system.
17. A horizontal vent pipe must be graded back toward the drainage pipe at what slope?
A. 1/8 inch per foot B. 1/4 inch per foot C. Level D. As steep as possible
1/8 inch per foot