Home Inspection Electrical EXAM Questions & Answers | With 100%
Correct Answers graded A+ (updated 2026) Guaranteed Success!!
Electrical services within the scope of the IRC are limited to _____________________-volt, 0- to
_____________________-ampere, single-phase systems - (ANSWER)120/240v; 400amp
The markings for identification of disconnecting means shall have the durability to withstand the
_____________________ involved. - (ANSWER)environment
Electrical panel boards and overcurrent protection devices shall not be located in
_____________________. - (ANSWER)clothes closets, bathrooms, or over the steps of a stairway
Connected to establish electrical continuity and conductivity. - (ANSWER)bonded (bonding)
Overhead service-drop conductors shall have a vertical clearance of not less than
_____________________ feet above the roof surface. - (ANSWER)8'
Over residential property and driveways, service-drop conductors shall have _____________________
feet minimum clearance above final grade. - (ANSWER)12'
In no case shall the point of attachment for service drop conductors be less than
_____________________ feet above finished grade. - (ANSWER)10'
Above-ground service cables subject to physical damage shall be protected by Schedule
_____________________ PVC conduit. - (ANSWER)Schedule 80 PVC
Interior metal water piping located more than _____________________ feet from the point of entrance
to the building shall not be used as part of the grounding electrode system. - (ANSWER)5'
, Home Inspection Electrical EXAM Questions & Answers | With 100%
Correct Answers graded A+ (updated 2026) Guaranteed Success!!
Rob and pipe electrodes shall be not less than _____________________ feet in length. - (ANSWER)8
Bonding shall be provided where necessary to ensure electrical _____________________. -
(ANSWER)continuity
All mechanical elements used to terminate a grounding electrode conductor or bonding jumper to the
ground electrodes shall be _____________________. - (ANSWER)accessible
Where a branch circuit or a feeder supplies a continuous load, it shall have an ampacity of
_____________________ percent of the continuous load. - (ANSWER)125%
The rating of any one cord- and plug-connected utilization equipment shall not exceed
_____________________ percent of the branch-circuit ampere rating. - (ANSWER)80%
Branch circuit ratings for space-heating and water-heating appliances shall be considered
_____________________loads. - (ANSWER)continuous
A minimum of _____________________20-ampere-rated branch circuits shall be provided to serve all
wall and floor receptacle outlets located in the kitchen, pantry, breakfast area, and dining area (or similar
area) of a dwelling. - (ANSWER)two
A minimum of one ____________________-ampere-rated branch circuit shall be provided for
receptacles located in the laundry area and shall serve only receptacle outlets in the laundry area. -
(ANSWER)20-amp
Correct Answers graded A+ (updated 2026) Guaranteed Success!!
Electrical services within the scope of the IRC are limited to _____________________-volt, 0- to
_____________________-ampere, single-phase systems - (ANSWER)120/240v; 400amp
The markings for identification of disconnecting means shall have the durability to withstand the
_____________________ involved. - (ANSWER)environment
Electrical panel boards and overcurrent protection devices shall not be located in
_____________________. - (ANSWER)clothes closets, bathrooms, or over the steps of a stairway
Connected to establish electrical continuity and conductivity. - (ANSWER)bonded (bonding)
Overhead service-drop conductors shall have a vertical clearance of not less than
_____________________ feet above the roof surface. - (ANSWER)8'
Over residential property and driveways, service-drop conductors shall have _____________________
feet minimum clearance above final grade. - (ANSWER)12'
In no case shall the point of attachment for service drop conductors be less than
_____________________ feet above finished grade. - (ANSWER)10'
Above-ground service cables subject to physical damage shall be protected by Schedule
_____________________ PVC conduit. - (ANSWER)Schedule 80 PVC
Interior metal water piping located more than _____________________ feet from the point of entrance
to the building shall not be used as part of the grounding electrode system. - (ANSWER)5'
, Home Inspection Electrical EXAM Questions & Answers | With 100%
Correct Answers graded A+ (updated 2026) Guaranteed Success!!
Rob and pipe electrodes shall be not less than _____________________ feet in length. - (ANSWER)8
Bonding shall be provided where necessary to ensure electrical _____________________. -
(ANSWER)continuity
All mechanical elements used to terminate a grounding electrode conductor or bonding jumper to the
ground electrodes shall be _____________________. - (ANSWER)accessible
Where a branch circuit or a feeder supplies a continuous load, it shall have an ampacity of
_____________________ percent of the continuous load. - (ANSWER)125%
The rating of any one cord- and plug-connected utilization equipment shall not exceed
_____________________ percent of the branch-circuit ampere rating. - (ANSWER)80%
Branch circuit ratings for space-heating and water-heating appliances shall be considered
_____________________loads. - (ANSWER)continuous
A minimum of _____________________20-ampere-rated branch circuits shall be provided to serve all
wall and floor receptacle outlets located in the kitchen, pantry, breakfast area, and dining area (or similar
area) of a dwelling. - (ANSWER)two
A minimum of one ____________________-ampere-rated branch circuit shall be provided for
receptacles located in the laundry area and shall serve only receptacle outlets in the laundry area. -
(ANSWER)20-amp