QUESTIONS AND VERIFIED CORRECT
ANSWERS GRADED A+ LATEST 100%
GUARANTEED PASS
___ must follow a broadcast process that begins with a clear statement that alerts all listeners.
A.Arrival reports
B.Emergency radio traffic
C.Tactical progress reports
D.Additional resource requests - CORRECT ANSWER-B
p.119
Which of the following would be a reason to request a personnel accountability report (PAR)?
A.The primary search is started.
B.A secondary search is completed.
C.An emergency evacuation is ordered.
D.The public information officer requests it. - CORRECT ANSWER-C
,p.121
Green wood has a high ___ that affects burn rate.
A.spalling point
B.heat resistance
C.moisture content
D.failure temperature - CORRECT ANSWER-C
p.135
What type of common building material includes bricks, stones, and concrete blocks?
A.Wood
B.Metal
C.Masonry
D.Lath and Plaster - CORRECT ANSWER-C
p.135
Which of the following can be the result of rapidly cooling cast iron with water?
A.It may crack or shatter.
B.It may gain tensile strength.
C.It may lose small portions from the surface.
D.It may elongate as much as 4 inches (100 mm). - CORRECT ANSWER-A p.135
Which of the following construction types has walls, floors, and ceilings that must be able to
resist fire for three to four hours?
A.Type I
B.Type III
,C.Type IV
D.Type V - CORRECT ANSWER-A
p.144
What construction type is composed of materials that will not contribute to fire development or
spread?
A.Type I
B.Type II
C.Type III
D.Type IV - CORRECT ANSWER-B
p.144
Type III construction requires exterior walls and structural members to be constructed of:
A.wood and metal.
B.steel and masonry.
C.large-dimension lumber.
D.noncombustible materials. - CORRECT ANSWER-D
p.145
What building component is designed to support the weight of a building and all its contents?
A.Wall
B.Roof
C.Foundation
D.Floor/Ceiling - CORRECT ANSWER-C
p.158
, Knowing types of doors and door hardware can help firefighters:
A.judge roof safety.
B.predict fire development.
C.select correct forcible entry tools.
D.select the right type of vertical tactical ventilation. - CORRECT ANSWER-C
p. 190
The critical temperature for steel trusses is:
A.300¡F (149¡C).
B.500¡F (260¡C).
C.900¡F (482¡C).
D.1,000¡F (538¡C). - CORRECT ANSWER-D
p.193
Which type of roof is used whenever large open floor spaces with limited interior support is
needed?
A.Lantern
B.Mansard
C.Sawtooth
D.Bowstring truss - CORRECT ANSWER-D
p.193
Which of the following BEST describes when structural collapse may occur?
A.It can occur when all the factors are met.
B.It can only occur before fire suppression.
C.It can only occur during fire suppression.