✔✔A rupture disc on a recovery vessel for low pressure refrigerants relieves at:
________.

a) 5 psig
b) 10 psig
c) 15 psig
d) 20 psig - ✔✔c) 15 psig

✔✔The primary water source for a recovery unit condensing coil is: _________.

a) chilled water
b) condenser water
c) local municipal water supply
d) de-ionized water - ✔✔c) local municipal water supply

✔✔Which of the following repairs that would ALWAYS be considered "major" under
EPA's regulations?

a) replacement of an evaporator coil
b) replacement of a filter-drier

,c) replacement of a switch
d) replacement of a purge unit - ✔✔a) replacement of an evaporator coil

✔✔According to the EPA, there is approximately ________ of refrigerant vapor left in an
average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been
removed.

a) None.
b) 10 pounds.
c) 20 pounds.
d) 100 pounds. - ✔✔d) 100 pounds.

✔✔A centrifugal chiller's rupture disk is connected to the chiller's: ________.

a) condenser
b) evaporator
c) liquid line
d) economizer - ✔✔b) evaporator

✔✔When charging a chiller, refrigerant vapor is introduced into the system before
charging with liquid. That is because: ___________.

a) vapor charging increases pressure slowly, preventing failure of the rupture disc
b) vapor charging is faster than liquid charging
c) liquid charging is more difficult to control than vapor charging
d) liquid charged into a deep vacuum will cause the refrigerant to boil and lower
temperatures enough to freeze the water in the tubes - ✔✔d) liquid charged into a deep
vacuum will cause the refrigerant to boil and lower temperatures enough to freeze the
water in the tubes

✔✔To determine how much vapor to charge into an evacuated chiller, you should
charge with vapor until: __________.

a) the system pressure corresponds to a refrigerant saturation temperature of 36
degrees F
b) the recovery unit liquid level drops
c) you have charged with vapor for 15 minutes
d) the recovery unit pressure drops - ✔✔a) the system pressure corresponds to a
refrigerant saturation temperature of 36 degrees F

✔✔When there is excessive moisture collecting in the purge unit of a low pressure
refrigeration system, this indicates that: _________.

a) the system was charged with contaminated refrigerant
b) the condenser or chiller barrel tubes are leaking

, c) the purge unit is not operating properly
d) the purge unit needs adjustment - ✔✔b) the condenser or chiller barrel tubes are
leaking

✔✔During chiller evacuation, water is circulated to: _________.

a) speed up the recovery process
b) prevent loss of refrigerant to the atmosphere
c) prevent freezing of the water
d) maintain constant refrigerant pressure - ✔✔c) prevent freezing of the water

✔✔A system does not have to be evacuated all the way to the required level when:
__________.

a) the repair is major
b) the repair is followed by an evacuation of the appliance to the environment
c) the appliance is being disposed of
d) leaks in the appliance make evacuation to the prescribed level unattainable - ✔✔d)
leaks in the appliance make evacuation to the prescribed level unattainable

✔✔What is meant by the term "high efficiency purge unit"?

a) Those purge units which discharge a high percentage of refrigerant with the air which
they remove.
b) Those purge units which discharge a low percentage of refrigerant with the air which
they remove.
c) Those purge units which draw very little electrical power.
d) None of the above. - ✔✔b) Those purge units which discharge a low percentage of
refrigerant with the air which they remove.

✔✔The maximum test pressure for leak testing a low pressure centrifugal is: ________.

a) 0 psig
b) 10 psig
c) 25 psig
d) 50 psig - ✔✔b) 10 psig

✔✔When recharging a refrigeration system with R-11, what vapor pressure is
necessary in the shells before charging with liquid?

a) 21.1 inches of Hg vacuum
b) 19.7 inches of Hg vacuum
c) 18.1 inches of Hg vacuum
d) 16.9 inches of Hg vacuum - ✔✔d) 16.9 inches of Hg vacuum

Written for

Institution
EPA 608 TYPE III
Course
EPA 608 TYPE III

Document information

Uploaded on
July 11, 2026
Number of pages
18
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$16.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXAMCAFE Chamberlain College Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
145
Member since
1 year
Number of followers
5
Documents
26088
Last sold
1 day ago
EXAM CAFE

NBA FINALS.....CRAZY TIMES Welcome to Exam Docs Hub, the ultimate online destination for high-quality exam documents, study guides, and academic resources to help you excel in your studies! Whether you're preparing for final exams, standardized tests, certifications, or coursework, we provide comprehensive and well-structured materials to boost your confidence and performance. Our collection includes: ✅ Past exam papers for various subjects ✅ Study guides & summaries to simplify learning ✅ Practice tests & quizzes to assess your knowledge ✅ Detailed solutions & answer keys for effective revision At Exam Docs Hub, we prioritize accuracy, quality, and accessibility. Our resources are carefully curated to meet the needs of students, educators, and professionals. With instant downloads and user-friendly access,

Read more Read less
3.2

17 reviews

5
6
4
3
3
2
2
1
1
5

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions