1. What is the primary responsibility of the S96 Certificate of Fitness holder?
A. Installing new fire alarm systems
B. Supervising the inspection, testing, and maintenance of fire alarm systems
C. Designing fire protection systems
D. Approving building construction plans
Answer: B. Supervising the inspection, testing, and maintenance of fire alarm
systems
Explanation: The S96 Certificate of Fitness authorizes qualified individuals to
supervise the inspection, testing, and maintenance of fire alarm systems to
ensure they remain operational and code compliant.
2. Before beginning any fire alarm system testing, the supervising certificate
holder should first:
A. Disconnect all initiating devices
B. Notify the building occupants and the monitoring company
C. Turn off the building's electrical service
D. Remove all smoke detectors
,Answer: B. Notify the building occupants and the monitoring company
Explanation: Proper notification prevents unnecessary emergency responses and
informs occupants that alarm testing is taking place.
3. Which document provides the primary standard for inspection, testing, and
maintenance of fire alarm systems?
A. OSHA 1910
B. NFPA 70
C. NFPA 72
D. NFPA 13
Answer: C. NFPA 72
Explanation: NFPA 72 establishes the inspection, testing, and maintenance
requirements for fire alarm and signaling systems.
4. During a scheduled inspection, a smoke detector fails to activate during
testing. What should be done?
A. Ignore the detector if others function properly
B. Record the deficiency and arrange for repair or replacement
C. Disable the circuit permanently
D. Remove the detector without documentation
Answer: B. Record the deficiency and arrange for repair or replacement
Explanation: Any deficiency discovered during inspection or testing must be
documented and corrected promptly.
5. Manual pull stations should be tested to verify:
A. Paint color only
B. Activation of the alarm system and proper signal transmission
C. Door operation only
, D. HVAC airflow
Answer: B. Activation of the alarm system and proper signal transmission
Explanation: Testing confirms that manual pull stations activate the alarm system
and transmit signals correctly.
6. A supervisory signal generally indicates:
A. A confirmed fire emergency
B. A maintenance or abnormal condition requiring attention
C. Normal system operation
D. Complete system shutdown
Answer: B. A maintenance or abnormal condition requiring attention
Explanation: A supervisory signal alerts personnel to abnormal conditions
affecting fire protection equipment but not necessarily a fire.
7. Which of the following is considered an initiating device?
A. Horn
B. Strobe light
C. Smoke detector
D. Fire alarm control panel
Answer: C. Smoke detector
Explanation: A smoke detector initiates an alarm condition when smoke is
detected.
8. The fire alarm control panel primarily serves to:
A. Extinguish fires
B. Receive signals, process information, and activate notification appliances
C. Supply water to sprinklers