Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

FDNY Z51 RMO 2026 EXAMINATION SET QUESTIONS AND ANSWERS RATED A.pdf

Rating
-
Sold
-
Pages
9
Grade
A+
Uploaded on
10-07-2026
Written in
2025/2026

FDNY Z51 RMO 2026 EXAMINATION SET QUESTIONS AND ANSWERS RATED A.pdf

Institution
FDNY Z51 RMO
Course
FDNY Z51 RMO

Content preview

FDNY Z51 RMO 2026 EXAMINATION SET QUESTIONS
AND ANSWERS RATED A+
✔✔How would you put an additional pump online? - ✔✔Open suction valve, open
discharge valve gradually

✔✔Of the following, the major advantage of a shell and coil condenser is: - ✔✔There is
less dangers of developing leaks

✔✔An engineer needs to vary the flow of refrigerant in a refrigeration system. which
operation in the flow of the system does not include: - ✔✔Solenoid valve

✔✔thermal bulb is attached to the suction pipe between the evaporator coil and the
compressor by an insulated line. assume that the machinery room is at 85F. break
down of the insulation results in: - ✔✔Flood the evaporator

✔✔A chill water system uses refrigerant R134 a leak in the evaporator shell may result
in: - ✔✔Set off the refrigerant monitor alarm

✔✔What are steam ejector used for on the surface condenser of a system with a
turbine: - ✔✔To create a proper opening exhaust system

✔✔Water and moisture is serious problem in a refrigerant system how to avoid: -
✔✔Proper evacuation at the charging of the system

✔✔The most important requirements for a good evaporator is that: - ✔✔It must have
enough cooling surface to absorb the required heat

✔✔While on duty a refrigeration engineer notice that the suction line to the compressor
and part of the compressor itself is frosted of the following, the most likely reason for
this condition would be: - ✔✔There is not enough refrigerant in the system

, ✔✔While doing a routine line inspection, the engineer notices the bulb of the TXV on
the floor refrigerant engineer should attach bulb at the : - ✔✔The outlet end of the coil

✔✔To convert water 32F to ice at the same temperature a refrigeration system must
remove: - ✔✔The latent heat of fusion

✔✔The use of oil in the refrigeration machine is to: - ✔✔Reduce wear and friction in the
compressor parts

✔✔The following is a desirable property in a refrigeration - ✔✔High latent heat

✔✔The cooling medium for an evaporative condenser is: - ✔✔Air and water

✔✔The ratio of the actual pressure of water vapor in the atmosphere to the saturated
pressure of give temperature is: - ✔✔Relative humidity

✔✔The only refrigerant/ temperature chart available to a refrigerant engineer list the
temperature is degrees Celsius if the chart indicates a Celsius temperature of 4 degrees
to equivalent to F: - ✔✔39.2 degrees

✔✔A refrigerant engineers was instructed to charge of 60 ton plant with R134A
refrigerant. the refrigerant engineer will most likely find the charging valve on the -
✔✔Low pressure side of the system

✔✔A refrigerant engineer verifies that a chilled water pump is cavitating. of the following
the most likely cause for this condition is: - ✔✔Water leaks through the mechanical
seals

✔✔There is a decrease in the efficiency of a reciprocating compressor. this most likely
caused by: - ✔✔Leaking suction valve

✔✔The suction and discharge valve of the reciprocating compressor are mounted as
follows: - ✔✔Discharge valves on top of the valve plate and suction valve below

✔✔You are the engineer running a 2000-ton (steam-driven turbine) centrifugal
refrigeration system, a refrigeration system supplies chilled water to a college campus
with multiple buildings. while making your rounds you notice that the discharge pressure
of your condenser water pumps is significantly lower than normal. which of the following
action would you avoid taking: - ✔✔Put on an additional surface condenser pump and
lower the chilled water set point

✔✔A water pump is discharge against head 92 feet of water, this is approximately to a
pressure of: - ✔✔40 psi

Written for

Institution
FDNY Z51 RMO
Course
FDNY Z51 RMO

Document information

Uploaded on
July 10, 2026
Number of pages
9
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$16.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
274
Member since
2 year
Number of followers
8
Documents
30733
Last sold
1 day ago
5 STAR ACADEMY

Military With Touch of Academics Ace Your Exams With Top Quality study Notes And Paper✅✅ EVERYTHING IS GRADED A+✅✅ COLOUR YOUR GRADES WITH US , WE ARE HERE TO HELP YOU DONT BE RELACTANT TO REACH US

3.5

40 reviews

5
14
4
6
3
12
2
1
1
7

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions