Master the North Dakota Master Electrician license exam with this comprehensive study guide featuring 400 practice questions with detailed rationales aligned with the North Dakota State Electrical Board (NDSEB) examination blueprint. This complete exam resource covers the National Electrical Code (NEC) including Article 250 grounding and bonding, services and feeders, branch circuits, overcurrent protection, motor controls and transformers, hazardous locations, load calculations, box fill, and North Dakota Administrative Code requirements. Each question includes correct answers with expert rationales explaining the NEC references, electrical theory, and state-specific regulations. The North Dakota Master Electrician exam is a rigorous open-book assessment requiring proficiency in complex load calculations, wiring methods, and code navigation under timed conditions. Candidates must have at least 10,000 hours of electrical experience. Perfect for master electrician candidates, journeymen upgrading their license, and electrical professionals seeking NDSEB certification. Pass your North Dakota Master Electrician exam on the first attempt with targeted practice across all exam domains.

Show more Read less
Institution
NORTH DAKOTA MASTER ELECTRICIAN
Course
NORTH DAKOTA MASTER ELECTRICIAN

Content preview

NORTH DAKOTA MASTER ELECTRICIAN EXAMINATION
COMPLETE PRACTICE EXAM – 400 QUESTIONS WITH DETAILED
SOLUTIONS UPDATED TO CURRENT NEC CYCLE

SECTION 1: NEC GENERAL REQUIREMENTS & DEFINITIONS (Questions 1-50)
1. According to the National Electrical Code, what is the primary purpose of
requiring electrical installations to comply with minimum safety standards
throughout their design, installation, and maintenance?
A. To reduce installation costs for contractors
B. To provide practical safeguarding of persons and property from electrical
hazards
C. To guarantee uninterrupted electrical service under every condition
D. To maximize equipment operating efficiency regardless of installation quality
Correct Answer: B
Rationale: NEC 90.1(A) states that the purpose of the Code is the practical
safeguarding of persons and property from hazards arising from the use of
electricity. It establishes minimum safety requirements rather than guaranteeing
service continuity or equipment efficiency.

2. What NEC article covers grounding and bonding?
A. Article 110
B. Article 210
C. Article 230
D. Article 250
Correct Answer: D
Rationale: Article 250 of the NEC governs all grounding and bonding requirements
for electrical systems.

3. The maximum number of disconnects allowed for a service is:
A. 4
B. 5
C. 6
D. Unlimited

1

,Correct Answer: C
Rationale: NEC 230.71 permits up to six service disconnecting means per service.

4. What is the minimum working space depth required for equipment operating
at up to 150 volts to ground?
A. 2 feet
B. 3 feet
C. 4 feet
D. 5 feet
Correct Answer: B
Rationale: NEC 110.26(A)(1) requires a minimum working space depth of 3 feet
for equipment with voltage to ground up to 150V.

5. The minimum cover depth for rigid metal conduit (RMC) under a residential
driveway is:
A. 6 inches
B. 12 inches
C. 18 inches
D. 24 inches
Correct Answer: B
Rationale: NEC Table 300.5 requires 12 inches of cover for rigid metal conduit
under residential driveways.

6. A neutral conductor is considered a current-carrying conductor for ampacity
adjustment when:
A. It carries only unbalanced current in a multiwire branch circuit
B. It is part of a 3-wire, single-phase circuit supplying a resistive load
C. It is part of a 4-wire, 3-phase wye system where the load is nonlinear
D. It serves as the grounded conductor for a service
Correct Answer: C
Rationale: NEC 310.15(E) requires the neutral to be counted as a current-carrying
conductor in a 4-wire, 3-phase wye system when the load consists of nonlinear
loads (e.g., harmonics).

2

,7. The minimum size copper equipment grounding conductor for a 60-ampere
overcurrent device is:
A. 14 AWG
B. 12 AWG
C. 10 AWG
D. 8 AWG
Correct Answer: C
Rationale: NEC Table 250.122 requires a 10 AWG copper equipment grounding
conductor for a 60A overcurrent protective device.

8. What is the maximum allowable fill for a conduit containing three or more
conductors?
A. 31%
B. 40%
C. 53%
D. 60%
Correct Answer: B
Rationale: NEC Chapter 9, Table 1 allows a maximum fill of 40% for conduits with
three or more conductors.

9. Which of the following is NOT an identified purpose of the NEC?
A. Safeguarding persons from electrical hazards
B. Safeguarding property from electrical hazards
C. Ensuring energy efficiency of electrical equipment
D. Establishing minimum safety requirements
Correct Answer: C
Rationale: NEC 90.1(A) and (B) state the Code is for safety and minimum
standards, not energy efficiency or design specifications.

10. The term "readily accessible" means:
A. Capable of being reached quickly without climbing over obstacles
B. Requires a tool to open a door or cover

3

, C. Located in a locked room
D. Only accessible to qualified persons
Correct Answer: A
Rationale: NEC Article 100 defines "readily accessible" as capable of being
reached quickly for operation, renewal, or inspections, without requiring the use
of tools or climbing over obstacles.

11. The interrupting rating of a circuit breaker must be at least the:
A. Continuous load current
B. Available fault current at its terminals
C. Normal operating current of the load
D. Locked-rotor current of the largest motor
Correct Answer: B
Rationale: NEC 110.9 requires equipment intended to interrupt current at fault
levels to have an interrupting rating sufficient for the nominal circuit voltage and
the current available at its terminals.

12. When a dwelling unit has a 200-ampere service, the minimum size of the
grounded service conductor (neutral) per Table 250.102(C)(1) for copper is:
A. 4 AWG
B. 3 AWG
C. 2 AWG
D. 1/0 AWG
Correct Answer: A
Rationale: For a 200A service, Table 250.102(C)(1) specifies the minimum copper
grounded conductor size as 4 AWG for service-entrance conductors.

13. A single receptacle installed on an individual branch circuit must have an
ampere rating:
A. Equal to the branch circuit rating
B. Greater than the branch circuit rating
C. Not less than the branch circuit rating
D. Less than the branch circuit rating

4

Written for

Institution
NORTH DAKOTA MASTER ELECTRICIAN
Course
NORTH DAKOTA MASTER ELECTRICIAN

Document information

Uploaded on
July 9, 2026
Number of pages
109
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • nd electrical
$23.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PrepMaster NURSING, ECONOMICS, MATHEMATICS, BIOLOGY, AND HISTORY MATERIALS BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS, AND STUDY GUIDE MATERIALS WITH GUARANTEED A+ I am a dedicated medical practitioner with diverse knowledge in matters
View profile
Follow You need to be logged in order to follow users or courses
Sold
268
Member since
1 year
Number of followers
18
Documents
2633
Last sold
1 hour ago
ExamZen

A GOLD-TOP RATED SELLER ON STUVIA WITH WELL DETAILED AND VERIFIED STUDY DOCUMENTS ASSURED WITH EXCELLENT AND REMARKABLE RESULTS. Welcome to ExamZen, your go-to source for high-quality test banks and study materials designed to help you excel academically. We offer a comprehensive range of resources including test banks, study guides, solution manuals, and other study materials, all meticulously curated to ensure accuracy and effectiveness. Our affordable, instantly accessible materials are complemented by excellent customer support, making your learning experience seamless and efficient. Trust ExamZen to be your partner in academic success, providing the tools you need to achieve your educational goals.

Read more Read less
4.8

309 reviews

5
267
4
29
3
4
2
2
1
7

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions