EPA SECTION 609 CERTIFICATION EXAM: 200 PRACTICE QUESTIONS WITH ANSWERS & RATIONALES 1. A refillable refrigerant cylinder must not be filled above ______ of its full capacity. A) 60% B) 80% C) 90% D) 100% Correct Answer: B) 80% Rationale: Safety regulations mandate that refillable cylinders are not filled beyond 80% to allow for thermal expansion and prevent rupture. ________________________________________ 2. Ozone layer absorbs and scatters ______ from the sun. A) Infrared light B) Ultraviolet light C) Visible light D) Radio waves Correct Answer: B) Ultraviolet light Rationale: The ozone layer is crucial for absorbing and scattering harmful ultraviolet (UV) radiation from the sun. ________________________________________ 3. An award of up to ______ may be paid to a person supplying information that leads to a penalty against a technician who is intentionally venting. A) $1,000 B) $5,000 C) $10,000 D) $25,000 **Correct Answer: C) $10,000** *Rationale:* The EPA provides a reward of up to $10,000 for information leading to penalties against illegal venting. ________________________________________ 4. Since ______, it is no longer legal for CFCs to be manufactured or imported into the United States. A) Jan 1, 1990 B) Jan 1, 1995 C) Jan 1, 1996 D) Nov 15, 1995 Correct Answer: C) Jan 1, 1996 Rationale: The production and import of CFCs were banned in the U.S. effective January 1, 1996. ________________________________________ 5. R-134a is a chlorine-free refrigerant. A) True B) False Correct Answer: A) True Rationale: R-134a is a hydrofluorocarbon (HFC) and does not contain chlorine, making it ozone-friendly. ________________________________________ 6. MVAC systems being disposed must be evacuated to ______ of mercury before being scrapped. A) 2 inches B) 3 inches C) 4 inches D) 5 inches Correct Answer: C) 4 inches Rationale: Mobile Vehicle Air Conditioning (MVAC) systems must be evacuated to 4 inches of mercury vacuum before disposal. ________________________________________ 7. Ozone at ground level and at Stratosphere is a harmful pollutant. A) True B) False Correct Answer: B) False Rationale: Ground-level ozone is a pollutant, but stratospheric ozone is beneficial as it blocks UV radiation. ________________________________________ 8. Each chlorine ion can destroy ______ ozone molecules. A) 1,000 B) 10,000 C) 100,000 D) 1,000,000 Correct Answer: C) 100,000 Rationale: A single chlorine atom can catalyze the destruction of up to 100,000 ozone molecules. ________________________________________ 9. Since ______, it is illegal to vent substitutes for CFC and HCFC refrigerants. A) Jan 1, 1990 B) Nov 15, 1995 C) Jan 1, 1996 D) July 1, 1992 Correct Answer: B) Nov 15, 1995 Rationale: The EPA banned venting of substitutes for CFCs and HCFCs starting November 15, 1995. ________________________________________ 10. For determining the Ozone Depletion Potential ______ having been assigned a factor of 1. A) CFC-12 B) CFC-11 C) HCFC-22 D) HFC-134a Correct Answer: B) CFC-11 Rationale: CFC-11 is the reference substance with an ODP of 1.0. ________________________________________ 11. Ester-based synthetic oils can be mixed with other oils. A) True B) False Correct Answer: B) False Rationale: Ester oils (POE) should not be mixed with mineral or alkylbenzene oils as it can cause breakdown and system failure.

Content preview

EPA SECTION 609 CERTIFICATION EXAM: 200
PRACTICE QUESTIONS WITH ANSWERS & RATIONALES




1. A refillable refrigerant cylinder must not be filled above ______ of
its full capacity.
A) 60%
B) 80%
C) 90%
D) 100%
Correct Answer: B) 80%
Rationale: Safety regulations mandate that refillable cylinders are not
filled beyond 80% to allow for thermal expansion and prevent rupture.


2. Ozone layer absorbs and scatters ______ from the sun.
A) Infrared light
B) Ultraviolet light
C) Visible light
D) Radio waves
Correct Answer: B) Ultraviolet light
Rationale: The ozone layer is crucial for absorbing and scattering
harmful ultraviolet (UV) radiation from the sun.

,3. An award of up to ______ may be paid to a person supplying
information that leads to a penalty against a technician who is
intentionally venting.
A) $1,000
B) $5,000
C) $10,000
D) $25,000
**Correct Answer: C) $10,000**
*Rationale:* The EPA provides a reward of up to $10,000 for
information leading to penalties against illegal venting.


4. Since ______, it is no longer legal for CFCs to be manufactured or
imported into the United States.
A) Jan 1, 1990
B) Jan 1, 1995
C) Jan 1, 1996
D) Nov 15, 1995
Correct Answer: C) Jan 1, 1996
Rationale: The production and import of CFCs were banned in the U.S.
effective January 1, 1996.


5. R-134a is a chlorine-free refrigerant.
A) True
B) False
Correct Answer: A) True
Rationale: R-134a is a hydrofluorocarbon (HFC) and does not contain
chlorine, making it ozone-friendly.

,6. MVAC systems being disposed must be evacuated to ______ of
mercury before being scrapped.
A) 2 inches
B) 3 inches
C) 4 inches
D) 5 inches
Correct Answer: C) 4 inches
Rationale: Mobile Vehicle Air Conditioning (MVAC) systems must be
evacuated to 4 inches of mercury vacuum before disposal.


7. Ozone at ground level and at Stratosphere is a harmful pollutant.
A) True
B) False
Correct Answer: B) False
Rationale: Ground-level ozone is a pollutant, but stratospheric ozone is
beneficial as it blocks UV radiation.


8. Each chlorine ion can destroy ______ ozone molecules.
A) 1,000
B) 10,000
C) 100,000
D) 1,000,000
Correct Answer: C) 100,000
Rationale: A single chlorine atom can catalyze the destruction of up to
100,000 ozone molecules.

, 9. Since ______, it is illegal to vent substitutes for CFC and HCFC
refrigerants.
A) Jan 1, 1990
B) Nov 15, 1995
C) Jan 1, 1996
D) July 1, 1992
Correct Answer: B) Nov 15, 1995
Rationale: The EPA banned venting of substitutes for CFCs and HCFCs
starting November 15, 1995.


10. For determining the Ozone Depletion Potential ______ having
been assigned a factor of 1.
A) CFC-12
B) CFC-11
C) HCFC-22
D) HFC-134a
Correct Answer: B) CFC-11
Rationale: CFC-11 is the reference substance with an ODP of 1.0.


11. Ester-based synthetic oils can be mixed with other oils.
A) True
B) False
Correct Answer: B) False
Rationale: Ester oils (POE) should not be mixed with mineral or
alkylbenzene oils as it can cause breakdown and system failure.

Document information

Uploaded on
July 8, 2026
Number of pages
64
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
IszackBd
5.0
(3)
Sold
45
Followers
3
Items
5810
Last sold
1 day ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions