●● In those portions of systems intended to handle oxygen at pressures
greater than 350 psi the interconnecting hose shall NOT contain
________ materials?
Answer: Polymeric


●● In a Category 1 Dental and Gas Vacuum Piping system, which of the
following is an NFPA 99 requirement for the labeling of pipes?
Answer: Color coding & non-standard pressure


●● Which of the following treatments shall be performed before brazing
cut ends of a tube to be installed in a medical gas piping system?
Answer: Cut ends shall be rolled smooth or deburred


●● Manifolds for gas cylinders shall actuate a(an) _______ signal and
shall activate an indicator at all _______ alarm panels to indicate when
or just before changeover from one header to the other.
Answer: Local, master


●● In a non-anesthetizing area, on which side of a zone valve shall the
pressure/vacuum sensor be located?

,Answer: Station outlet/inlet


●● What is the purpose of using an oxygen analyzer during the piping
purge prior to brazing?
Answer: Assure that all ambient air has been removed from the pipeline


●● A medical gas master or area alarm panel shall be set to actuate a(an)
_____ indicator when the communication with an alarm-initiating device
is disconnected.
Answer: Audible and visual


●● When an EOSC becomes the temporary supply source, a facility will
monitor the system by use of which of the following?
Answer: Providing four connection points to both master alarms


●● Which of the following conditions must be met where medical gas
and vacuum systems are installed by non-certified personnel?
Answer: installation by anyone other than 6010 certified personnel is
NOT permitted


●● Which of the following systems shall NOT be permitted to be
located in an outdoor enclosure?
Answer: Medical air compressor supply sources

,●● Metallic flexible joints are being used in the pipeline for vibration
control. Which of the following is NOT required of such joints?
Answer: suitable for service at 150 psig or above


●● who shall witness the installer-performed standing vacuum test?
Answer: the authority having jurisdiction, or its designee


●● the medical air compressor intake shall be located a minimum of
how many feet from any exhaust or plumbing vents?
Answer: 25 feet


●● the gas produced by evaporation from the secondary header in a
cryogenic liquid cylinder system shall enter the supply system ________
of the final line regulator.
Answer: upstream


●● with the approval of the Authority Having Jurisdiction, in which
areas shall the zone valves be permitted to be secured to prevent
inappropriate access?
Answer: pediatric


●● factory installed inlet tubes on station outlets shall be NOT less than
__________with 0.3 inch minimum inside diameter.
Answer: NPS 1/4, 3/8 in. O.D.

, ●● which of these operations would not breach the vacuum system?
Answer: testing a system component with a leak detector solution


●● except for valves in zone valve boxes, all valves shall be located in
secured areas such as locked pipe chases, or be __________.
Answer: latched or locked in operation position


●● medical gas Central Supply systems are NOT permitted to be located
where?
Answer: in an unlocked location


●● fittings, valves, and other components for field-installed positive
pressure distribution systems shall be ________ until prepared for
installation.
Answer: delivered sealed, labeled, and kept sealed


●● vacuum piping for __________ shall be connected separately from
the medical surgical system directly to the receiver tank through its own
isolation valve and fluid trap located at the receiver.
Answer: a teaching laboratory


●● NFPA 99 specifies that the medical gas piping system shall be
protected against all EXCEPT which of the following?

Written for

Institution
MED GAS
Course
MED GAS

Document information

Uploaded on
July 7, 2026
Number of pages
48
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Favorgrades Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
820
Member since
3 year
Number of followers
376
Documents
46573
Last sold
2 days ago
Favorgrades Emporium

3.8

193 reviews

5
81
4
44
3
33
2
11
1
24

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions