Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

PrepIQ Maine Nurse Midwife Advanced RN Ultimate Exam COMPLETE QUESTIONS AND VERIFIED

Rating
-
Sold
-
Pages
164
Grade
A+
Uploaded on
07-07-2026
Written in
2025/2026

PrepIQ Maine Nurse Midwife Advanced RN Ultimate Exam COMPLETE QUESTIONS AND VERIFIED

Institution
Exmm
Course
Exmm

Content preview

Page 1 of 164


Pennsylvania (Philadelphia) Standard
Journeyman Plumber - 250_PA_PH Contractor
Exam Questions & Rationales VERIFIED
SOLUTIONS LATEST UPDATE THIS YEAR
Pennsylvania (Philadelphia) Standard Journeyman Plumber - 250_PA_PH Contractor Exam
Exam Coverage Summary
Based on Philadelphia Code requirements and the 2018 Philadelphia Plumbing Code (a locally
amended version of the International Plumbing Code), this exam covers :
• Licensing & Regulations: Philadelphia Code Chapter 9-1003 governs plumber licensing;
the Philadelphia Plumbing Advisory Board administers exams through the Department
of Licenses and Inspections (L&I) . Journeyman applicants must have been registered
apprentices for not less than four years .
• Drainage Systems: Minimum slope for 2½"–3" pipe is ¼ inch per foot . Cleanouts
required within 10 feet of changes in horizontal direction . House traps must be at least
the size of the house drain pipe, with fresh air inlet located not within 10 feet of
doors/windows/air intakes .
• Trap Requirements: Minimum water seal of 2 inches (not exceeding 4 inches) . Crown-
vented traps are prohibited . Minimum trap size for kitchen sink: 1½ inches ; for
lavatory: 1¼ inches ; for clothes washer standpipe: 2 inches . Brass traps must have
minimum wall thickness of No. 17 Brown & Sharpe gauge .
• Venting: Offsets in vent lines must be at 45° minimum to horizontal . Vent terminations
must be at least 12 inches above roof .
• Water Distribution: Minimum water pressure at fixtures: 30 psi . Galvanized steel
is prohibited for new potable water distribution . Thermal expansion tanks required in
closed-loop systems .
• Fixtures & Special Requirements: Floor drains must have 3-inch minimum outlet . All-
gender restrooms require floor-to-ceiling partitions; urinals are not permitted in
facilities designed for all genders . Condensate drains require ⅛-inch per foot slope .
• Plan Reading: 25% of exam dedicated to plan reading and analysis .
• Exam Details: Administered by ICC; 75 questions, 3 hours, closed book, 75% passing
score .


QUESTIONS 1-50

,Page 2 of 164


1. According to the Philadelphia Plumbing Code, what is the minimum required water seal for


a typical fixture trap?



A) 1 inch


B) 2 inches


C) 4 inches


D) 6 inches



Answer: B) The Philadelphia Plumbing Code mandates each fixture trap have a water seal of not


less than 2 inches and not more than 4 inches to prevent sewer gases from entering buildings .




2. What is the minimum slope required for a 3-inch horizontal drainage pipe according to the


Philadelphia Plumbing Code?



A) ⅛ inch per foot


B) ¼ inch per foot

,Page 3 of 164


C) ⅜ inch per foot


D) ½ inch per foot



Answer: B) The code requires ¼ inch per foot slope for 2½" through 3" horizontal drainage


piping to maintain proper flow velocity and prevent blockages .




3. Which type of trap is PROHIBITED by the Philadelphia Plumbing Code?



A) P-trap


B) S-trap


C) Crown-vented trap


D) Drum trap



Answer: C) The code explicitly prohibits crown-vented traps as they are prone to siphoning and


self-scouring, which can break the water seal. Other prohibited types include traps with movable


parts and double traps without a fresh air inlet .

, Page 4 of 164


4. What is the minimum size trap and fixture drain required for a residential kitchen sink with


two compartments?



A) 1¼ inches


B) 1½ inches


C) 2 inches


D) 3 inches



Answer: B) Table P-506 in the Philadelphia Plumbing Code requires a residential kitchen sink—


single or double compartment—to have a minimum trap and fixture drain size of 1½ inches .




5. What is the minimum size for a floor drain outlet according to the Philadelphia Plumbing


Code?



A) 2 inches


B) 3 inches

Written for

Institution
Exmm
Course
Exmm

Document information

Uploaded on
July 7, 2026
Number of pages
164
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$29.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
lectbrains

Get to know the seller

Seller avatar
lectbrains Chamberlein University
View profile
Follow You need to be logged in order to follow users or courses
Sold
-
Member since
1 week
Number of followers
0
Documents
83
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions