Pass your Ohio journeyman plumber exam on the first try with 100 verified practice questions, correct answers, and detailed rationales. Covers IPC code, DWV systems, venting, water supply, and fixture requirements. Instant PDF download — study anywhere, anytime. Perfect for apprentices, trade school students, and licensing prep.

Content preview

Ohio Journeyman Plumber Exam
d d d




Practice Questions And Correct Answers (V
d d d d d




erified Answers) Plus Rationales 2026|202
d d d d




7 Q&A | Instant Download Pdf
d d d d d




1. The minimum size water service pipe allowed for a single-
d d d d d d d d d d




family dwelling is: d d




A. ½ inch d




B. ¾ inch d




C. 1 inch d




D. 1 ¼ inch d d




¾ inch
d




Rationale: Most plumbing codes, including Ohio, set ¾ inch as the minimu
d d d d d d d d d d d




m water service size for adequate flow and pressure.
d d d d d d d d




2. A plumbing vent must terminate how far above the roof?
d d d d d d d d d




A. 4 inches d




B. 6 inches d

, C. 8 inches
d




D. 6 inches minimum
d d d




6 inches minimum
d d




Rationale: Vents must extend at least 6 inches above the roof surface t
d d d d d d d d d d d d




o prevent blockages from snow and debris.
d d d d d d




3. The minimum slope for horizontal drainage piping smaller than 4 i
d d d d d d d d d d




nches is: d




A. 1/8 inch per foot d d d




B. 1/4 inch per foot d d d




C. 3/8 inch per foot d d d




D. 1/2 inch per foot d d d




1/4 inch per foot
d d d




Rationale: Codes require ¼ inch per foot slope for pipes less than 4 inch
d d d d d d d d d d d d d




es to maintain proper flow and prevent clogging.
d d d d d d d




4. The maximum vertical distance between a trap and its vent is:
d d d d d d d d d d




A. 2 feet d




B. 4 feet d




C. 6 feet d




D. 10 feet d




6 feet
d




Rationale: Code limits trap-to- d d d




vent distance to 6 feet for typical fixture drains to avoid siphoning.
d d d d d d d d d d d

,5. A cleanout must be installed at every change of direction greater than:
d d d d d d d d d d d




A. 30 degrees d




B. 45 degrees d




C. 90 degrees d




D. 180 degrees d




90 degrees
d




Rationale: Cleanouts are required at changes of direction of 90 degree
d d d d d d d d d d




s or more to allow rodding access.
d d d d d d




6. The minimum size trap for a bathtub is:
d d d d d d d




A. 1 ¼ inch
d d




B. 1 ½ inch
d d




C. 2 inches
d




D. 2 ½ inchesd d




1 ½ inch
d d




Rationale: Bathtubs require 1½ inch traps for sufficient drainage.
d d d d d d d d




7. The minimum size vent for a water closet is:
d d d d d d d d




A. 1 ¼ inch
d d




B. 1 ½ inch
d d




C. 2 inches
d




D. 3 inches d




2 inches
d




Rationale: Toilets require a 2-inch minimum vent size per code.
d d d d d d d d d

, 8. A plumbing vent cannot terminate within how many feet horizontally
d d d d d d d d d d




of a building air intake?
d d d d




A. 6 feet d




B. 10 feet d




C. 12 feet d




D. 15 feet d




10 feet d




Rationale: Vents must be at least 10 feet away horizontally from air intak
d d d d d d d d d d d d




es to prevent odors from entering buildings.
d d d d d d




9. The minimum depth of a building sewer below grade is:
d d d d d d d d d




A. 12 inches d




B. 18 inches d




C. 24 inches d




D. 30 inches d




12 inches
d




Rationale: Sewers must be buried at least 12 inches to provide frost an
d d d d d d d d d d d d




d mechanical protection.
d d




10. What is the maximum spacing of supports for horizontal copper t
d d d d d d d d d d




ubing (½ inch)? d d




A. 4 feet d




B. 6 feet d




C. 8 feet d




D. 10 feet d

Document information

Uploaded on
July 5, 2026
Number of pages
36
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Lectgrayson
3.9
(18)
Sold
108
Followers
5
Items
2347
Last sold
7 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions