ACTUAL COMPLETE 100 REAL EXAM QUESTIONS
AND CORRECT DETAILED ANSWERS (VERIFIED
ANSWERS) ALREADY GRADED A+.
Roofing insulation and membranes must be protected
from latent moisture in concrete decks. In northern
climates, this is usually
accomplished with:
ANSWERS: A
vapor retarder or
A venting sheet
Steel decks should be at least _ or heavier.
ANSWERS: 22g
,Insulation applied to steel roof decks before the roof
membrane is installed should be applied:
ANSWERS: In two separate layers where insulation thickness
permits
The top flanges of a steel roof deck should be installed:
ANSWERS: Perpendicular to the roof slope
The maximum deflection allowed for a steel deck is:
ANSWERS: 1/4" per 100 feet
If the steel decks must be spot-welded to structural steel, puddle
welds
_______ or larger in diameter are recommended. They should be
made on washers and spaced at least _______ on center.
ANSWERS: 1/2 inches ... 12 inches
If thermosetting insulation is used over structural decks, the
density should be:
ANSWERS: 18 to 22 pounds per cubic foot
, The correct density for thermosetting insulation is accomplished
by:
ANSWERS: Compacting
Thermosetting insulation is compacted in two layers if the total
thickness is greater than:
ANSWERS: 6 inches
Thermosetting insulative fills must be protected from latent
moisture in roof decks. Which of the following procedures is
recommended?
ANSWERS:
Install base-ply vapor barrier and
Install wood nailers at all perimeters
and Install wood nailers at all roof
projections