Question >> 1
Which is a disadvantage of a packaged indoor unit
Answer>>
the potential for excessive noise exists
Question >> 2
Which type of cooling tower fill material design that spreads the water evenly to form
thin layers
Answer>>
film type
Question >> 3
All of the following are advantages of open compressors except
a. The compressor does not need to be replaced if the motor fails
Page 1 of 17
,b. easy to change pumping capacity
c. easy to change motors
d. does not need a shaft seal
Answer>>
does not need a shaft seal
Question >> 4
A change in heat result in a change in temperature but not in the state
Answer>>
sensible
Question >> 5
Which is most likely to cause high head pressure
a. low water temperature or ambient air temperature
b. inefficient compressor valves
c. low load condition
d. overcharge
Answer>>
overcharge (too much refrigerant)
Page 2 of 17
, Question >> 6
Where is a receiver located in a refrigeration system
Answer>>
after the condenser on the liquid line
Question >> 7
Which is most likely to cause low to no subcooling
a. oversized condenser
b. thermostatic expansion valve overfeeding
c. inefficient compressor
d. overcharge
Answer>>
thermostatic expansion valve overfeeding
Question >> 8
In a split system, the indoor section typically consist of the evaporator, fan, , and a
connection for the suction and liquid lines
Answer>>
a metering device
Page 3 of 17
Answers
Question >> 1
Which is a disadvantage of a packaged indoor unit
Answer>>
the potential for excessive noise exists
Question >> 2
Which type of cooling tower fill material design that spreads the water evenly to form
thin layers
Answer>>
film type
Question >> 3
All of the following are advantages of open compressors except
a. The compressor does not need to be replaced if the motor fails
Page 1 of 17
,b. easy to change pumping capacity
c. easy to change motors
d. does not need a shaft seal
Answer>>
does not need a shaft seal
Question >> 4
A change in heat result in a change in temperature but not in the state
Answer>>
sensible
Question >> 5
Which is most likely to cause high head pressure
a. low water temperature or ambient air temperature
b. inefficient compressor valves
c. low load condition
d. overcharge
Answer>>
overcharge (too much refrigerant)
Page 2 of 17
, Question >> 6
Where is a receiver located in a refrigeration system
Answer>>
after the condenser on the liquid line
Question >> 7
Which is most likely to cause low to no subcooling
a. oversized condenser
b. thermostatic expansion valve overfeeding
c. inefficient compressor
d. overcharge
Answer>>
thermostatic expansion valve overfeeding
Question >> 8
In a split system, the indoor section typically consist of the evaporator, fan, , and a
connection for the suction and liquid lines
Answer>>
a metering device
Page 3 of 17