Updated Review from Previously 60
Tested Questions | Grade A+
1. An oxygen deficient atmosphere is defined as one with on oxygen
percent less than -✓✓20.5
2. How many fires can be lit in a four-story non-gas fired burn building?
-✓✓1
3.Pilot flames should be _______with the fuel delivery valves to prevent
fuel from flowing without confirmed pilot flame being present. (1402
10.6.1 (C)) -✓✓Interlocked
4.Gas detection systems should be ____with the ventilation systems and
fuel delivery systems to shupt down fuel flow and activate an external
alarm when the levels exceed ______LEL. (1402 10.6.1 (D)) -
✓✓Interlocked, 25%
5. Smoke used in the training facility should 1404 11.4) -✓✓Non toxic
and of known substance
6. An Acquired Building is a structure acquired -✓✓By the authority
having jurisdiction from a property owner for the purpose of conducting
live fire evolutions. (1403 3.3.2.1)
, 7. A training center burn building is a structure -✓✓designed for
conducting live fire training evolutions on a repetitive basis. (1403
. A participant is -✓✓any student, instructor, safety officer, visitor, or
person who is involved in the live fire training evolution within the
operations area.
an individual appointed by the AHJ as qualified to maintain a safe
working environment at all live fire training evolutions -✓✓Safety
officer
any person who is present at the live fire training evolution for the
purpose of receiving training. (1403 3.3.10) -✓✓A student
Minimum qualification to participate in live fire training -✓✓All
participates shall have had Firefighter I training
2. All hazardous structural conditions shall -✓✓be removed or repaired
as to not present a safety problem during use of the structure for live fire
training evolutions. (1403
Missing stair treads and rails -✓✓shall be repaired or replaced
Holes in walls and ceilings -✓✓shall be patched