The minimum size equipment grounding conductor for Ampacities, Grounding
a 100 ampere, 120/240 volt single phase underground 250.122(B) Table 250.122 Table 8 Ch 9
dwelling feeder whose ungrounded conductors have
been increased in size from 3 AWG copper to 1 AWG answer: 4
copper is __ AWG copper
The continuity of the grounded conductor shall Continuity, Grounded conductors
depend on a busbar or __ only. 200.12
answer: wire
Each multi-wire branch circuit shall be provided with a Disconnecting means, Branch circuits, multiwire
means that will ____ disconnect all ungrounded 210.4(B)
conductors at the point where the branch circuit
originates. answer: simultaneously
Residential Wireman Electrical Exam.pdf Residential Wireman Electrical Exam.pdf Residential Wireman Electrical Exam.pdf
, Residential Wireman Electrical Exam Residential Wireman Electrical Exam.pdf Residential Wireman Electrical Exam.pdf
Balconies, decks, and porches that are accessible from Balconies, outdoor, receptacles for,
the inside of the dwelling unit shall have at least one 210.52(E)(3)
receptacle not more than __ ft. above the balcony,
deck, or porch surface. answer: 6 1/2
Where it is impracticable to locate the service head Service drops, Connections, service head
above the point of attachment, the service head 230.54 (C) Exception
location shall be permitted not farther than ___ inches
from the point of attachment. answer: 24
True/False: One of the means by which grounding Connection of Grounding and Bonding Equipment
conductors and bonding jumpers shall NOT be 250.8
connected by is machine screw type fasteners.
answer: false